arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
The paper introduces a geometry‑guided sampling operator that directs feature sampling rather than altering convolution kernels in 3D encoder‑decoder networks. By predicting local orientations and bounded step sizes, the operator samples symmetrically around each voxel, generating compact geometric and boundary cues that improve fine‑structure segmentation. Replacing stride‑1 and stride‑2 operations in a 3D U‑Net yields consistent gains on BraTS, MSD Hepatic Vessel, and TDSC‑ABUS datasets, with better boundary metrics and fewer parameters, and the operator can be integrated into other backbones without architectural changes.
By Sizhe Wang, Himashi Peiris, Zhaolin Chen
The paper introduces a structure‑aware federated learning framework for segmenting catheters and guidewires in X‑ray fluoroscopy. It presents a new benchmark dataset, CathAction, and a shape‑sensitive loss that improves segmentation accuracy. The approach extends to federated learning, adding projected gradient descent for adversarial optimization, and includes a diffusion‑based synthetic data generator that boosts performance under data scarcity.
By Chayun Kongtongvattana
arXiv:2608. 12274v1 Announce Type: cross Abstract: Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.
By Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind
VeCAS is a two‑stage framework that generates contrast‑free X‑ray angiograms from non‑contrast images. Stage I localizes vascular structures using a discriminative model and cross‑modality latent distillation, while Stage II synthesizes angiographic appearance within those regions with a vessel‑focused inpainting model. Experiments on a lower‑limb vascular intervention dataset show that VeCAS improves vascular structural fidelity and image quality, and robotic guidewire navigation tests demonstrate significant reductions in time to target and operation steps.
By De-Xing Huang, Chen-Yu Wang, Hao Liang, Xiao-Hu Zhou, Mei-Jiang Gui, Tian-Yu Xiang, Qin-Yi Zhang, Chen Wang, Xiao-Liang Xie, Shi-Qi Liu, Ming-Yuan Liu, Zhen-Chang Wang, Zeng-Guang Hou
X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learnin...