The paper presents a coordinate‑free 3‑D neural network with 597,032 parameters for extracting bilateral coronary artery trees from cardiac CT angiography. Using 35 training scans, the authors develop an 8.0 mm corridor solver refined by a learned medial offset, and evaluate the method on 50 ImageCAS and 40 ASOCA scans. Results show superior per‑artery Chamfer distance and centerline F1 scores compared to existing skeletonization and Voronoi‑based methods, achieving fast inference (≈1.66 s/scan) on an NVIDIA L4 GPU.
By Zeyu Jia, Tong Wu, Bo Yao, Xin Ming
arXiv:2608. 12274v1 Announce Type: cross Abstract: Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy.
By Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim, Justine Cunningham, Hassan Bagher-Ebadian, Dongxiao Zhu, Kundan S. Thind
arXiv:2608.30404v1 Announce Type: cross
Abstract: Accurate segmentation of the coronary vessel lumen is a prerequisite for quantitative assessment of atherosclerotic plaque and perivascular adipose t...
By Kit M. Bransby, Esther {\O}ksnebjerg, Kristoffer Kj{\ae}r, Jacob Kirkeby, Yasmin El Youssef, A\"ida Jim\'enez, Philip R. Pedersson, Martina C. de Knegt, Klaus F. Kofoed, Rasmus R. Paulsen
The paper presents a multi‑task neural network and scalar‑potential solver for reconstructing bilateral coronary artery trees from cardiac CT angiography. It operates on $128^3$ regions of interest, using a 3D pyramid encoder, tubular decoder, and specialized heads for sub‑voxel displacement, ipsilateral territory prediction, and ostium localization. The method achieves sub‑millimetre accuracy on out‑of‑sample and development datasets, outperforming baseline 3D U‑Net models.
By Zeyu Jia, Xin Ming
The paper presents CAG‑VLM, a fine‑tuned vision‑language model designed to interpret coronary angiography (CAG) images. A two‑stage pipeline first annotates 14,686 frames from 539 exams for key‑frame detection and laterality, achieving 0.96 F1 with a ConvNeXt‑Base CNN. The annotated data is then used to fine‑tune three open‑source VLMs via LoRA; Gemma3 w/LoRA receives the highest clinician rating (mean 7.20/10) and is designated as CAG‑VLM, demonstrating that specialized VLMs can aid cardiologists in generating reports and treatment recommendations from CAG images.
By Yuto Nakamura, Satoshi Kodera, Haruki Settai, Hiroki Shinohara, Masatsugu Tamura, Tomohiro Noguchi, Tatsuki Furusawa, Ryo Takizawa, Tempei Kabayama, Norihiko Takeda
The study investigates how few expert-annotated cases are needed to fine‑tune MedSAM3 for abdominal organ segmentation using Low‑Rank Adaptation (LoRA). With only 10 annotated CT or MRI cases, the LoRA‑adapted models achieve performance comparable to specialist systems that require orders of magnitude more data, including reliable gallbladder segmentation and near‑state‑of‑the‑art results for liver, kidneys, and spleen. The approach also generalizes to cardiac segmentation on the Whole Heart dataset, and training takes only 3–5 hours per organ on a single GPU, roughly twice as fast as nnU-Net.
By Sachin Dudda Nagaraju, Bendik Skarre Abrahamsen, Ashkan Moradi, Mattijs Elschot
arXiv:2606. 00109v1 Announce Type: cross Abstract: Coronary guidewire endpoint localization is a fundamental capability for computer-assisted PCI, and its importance increases as robot-assisted PCI is progressively adopted to reduce operator radiation exposure.
By Haoyuan Tang, Zhuo Zhang, Jialin Li, Shuai Xiao, Jiachen Yang
The paper introduces a novel 3‑D reconstruction framework for bilateral coronary artery trees from cardiac CT angiography, addressing limitations such as voxel quantization, territory ambiguity, and ostium drift. It employs a canonical SO(3) multi‑scale representation, a Riemannian arborescence solver, and a sub‑voxel displacement head, training 327,385 active parameters in a single 30‑epoch AdamW loop. On unseen datasets, the method achieves sub‑millimetre accuracy in centerline distance and ostial localisation, outperforming prior approaches.
By Zeyu Jia, Xin Ming
The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.
By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
arXiv:2312. 17670v5 Announce Type: replace-cross Abstract: The Circle of Willis (CoW) is an important network of arteries connecting major circulations of the brain.
By Kaiyuan Yang, Fabio Musio, Yihui Ma, Norman Juchler, Johannes C. Paetzold, Rami Al-Maskari, Luciano H\"oher, Hongwei Bran Li, Ibrahim Ethem Hamamci, Anjany Sekuboyina, Suprosanna Shit, Houjing Huang, Chinmay Prabhakar, Ezequiel de la Rosa, Bastian Wittmann, Diana Waldmannstetter, Florian Kofler, Fernando Navarro, Martin J. Menten, Ivan Ezhov, Daniel Rueckert, Iris N. Vos, Ynte M. Ruigrok, Birgitta K. Velthuis, Hugo J. Kuijf, Pengcheng Shi, Wei Liu, Ting Ma, Maximilian R. Rokuss, Yannick Kirchhoff, Fabian Isensee, Klaus Maier-Hein, Chengcheng Zhu, Huilin Zhao, Philippe Bijlenga, Julien H\"ammerli, Catherine Wurster, Laura Westphal, Jeroen Bisschop, Elisa Colombo, Hakim Baazaoui, Hannah-Lea Handelsmann, Andrew Makmur, James Hallinan, Amrish Soundararajan, Benedikt Wiestler, Jan S. Kirschke, Evamaria O. Riedel, Roland Wiest, Emmanuel Montagnon, Laurent Letourneau-Guillon, Kwanseok Oh, Dahye Lee, Orhun Utku Aydin, Adam Hilbert, Jana Rieger, Dimitrios Rallios, Satoru Tanioka, Alexander Koch, Dietmar Frey, Abdul Qayyum, Moona Mazher, Steven Niederer, Nico Disch, Julius C. Holzschuh, Dominic LaBella, Francesco Galati, Daniele Falcetta, Maria A. Zuluaga, Chaolong Lin, Haoran Zhao, Zehan Zhang, Minghui Zhang, Xin You, Hanxiao Zhang, Guang-Zhong Yang, Yun Gu, Sinyoung Ra, Jongyun Hwang, Hyunjin Park, Junqiang Chen, Marek Wodzinski, Henning M\"uller, Nesrin Mansouri, Florent Autrusseau, Cansu Yalcin, Rachika E. Hamadache, Clara Lisazo, Joaquim Salvi, Adri\`a Casamitjana, Xavier Llad\'o, Uma Maria Lal-Trehan Estrada, Valeriia Abramova, Luca Giancardo, Arnau Oliver, Paula Casademunt, Adrian Galdran, Matteo Delucchi, Oscar Camara, Jialu Liu, Haibin Huang, Yue Cui, Zehang Lin, Yusheng Liu, Shunzhi Zhu, Tatsat R. Patel, Adnan H. Siddiqui, Vincent M. Tutino, Maysam Orouskhani, Huayu Wang, Mahmud Mossa-Basha, Yuki Sato, Sven Hirsch, Susanne Wegener, Bjoern Menze
The study investigates self‑training for coronary vessel segmentation in X‑ray angiography, using pseudo‑labels from an nnU‑Net model trained on the ARCADE dataset and a contrast map derived from pre‑contrast frame subtraction. Six models were evaluated on ARCADE and two external datasets (XCAD and XACV); first‑round self‑training improved performance over baseline and a fine‑tuned control, with the XCAD model achieving a 2.7‑point Dice score increase. A second self‑training round yielded no further gains, and the benefit of self‑training was found to depend largely on the sensitivity of the initial pseudo‑label generator.
By Danial Moafi, Aida Moafi, Mostafa Aryafar, Ashkan Sami, Maryam Aryafar
arXiv:2609.00909v1 Announce Type: new
Abstract: Reliable evaluation of automated coronary computed tomography angiography (CCTA) report generation requires standardized multicentre benchmarks and cli...
By Zhiyu Ye, Yue Sun, Limiao Zou, Cheng Xu, Keting Xu, Tong Hu, Yue Yu, Hairong Zheng, Yining Wang, Tong Zhang