arXiv:2608. 17255v1 Announce Type: cross Abstract: X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
Generating a 3D dental volume from a single panoramic radiograph (PXR) could provide a low-radiation alternative to Cone-Beam Computed Tomography (CBCT), but the problem is highly underdetermined: panoramic acquisition integrates 3D attenuation along curved X-ray paths into a 2D image, leaving depth-resolved anatomy unobserved. Existing implicit and generative approaches often produce oversmoothed geometry or anatomically inconsistent hallucinations, lacking geometry-driven supervision and relying on smooth representations unable to precisely localize sharp anatomical boundaries.
arXiv:2505. 17338v3 Announce Type: replace-cross Abstract: Photorealistic volumetric rendering of CT scans greatly benefits clinical workflows, yet neural approaches such as Neural Radiance Fields (NeRF) and 3D Gaussian Splatting (3DGS) require prohibitive per-scan optimization (hours for NeRF, about 30 minutes for 3DGS), making them impractical in clinical settings.
By Zhongpai Gao, Benjamin Planche, Meng Zheng, Anwesa Choudhuri, Van Nguyen Nguyen, Terrence Chen, Ziyan Wu
arXiv:2607. 23343v1 Announce Type: cross Abstract: Intraoperative 2D/3D registration aligns preoperative CT volumes with intraoperative X-ray or fluoroscopic images and is essential for image-guided interventions.
By Minheng Chen, Youyong Kong
arXiv:2608. 03430v1 Announce Type: cross Abstract: Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts.
By Ivo Herzig, Pascal Paysan, Daniel Barco, Marc Andr\'e Stadelmann, Frank-Peter Schilling, Igor Peterlik, Michal Walczak, Lijin Aryananda, Woo Sang Ahn, Rudolf Marcel F\"uchslin, Lukas Lichtensteiger
Generating CT volumes from MRI and CBCT can improve treatment planning in adaptive radiotherapy while avoiding additional radiation exposure. However, direct regression of CT intensities is challenged by the inherently high dynamic range and long-tailed distributions, thereby averaging out sparse yet clinically important structures.
arXiv:2606. 17340v1 Announce Type: cross Abstract: Accurate vision-based navigation in monocular endoscopy is difficult due to limited depth cues, weak tissue texture, non-rigid deformation, and substantial appearance variation across domains, all of which complicate pose estimation, depth prediction, and image-to-anatomy alignment.
By Hongchao Shu, Roger D. Soberanis-Mukul, Hao Ding, Morgan Ringel, Mali Shen, Saif Iftekar Sayed, Hedyeh Rafii-Tari, Mathias Unberath
arXiv:2608. 00187v1 Announce Type: cross Abstract: Correspondence-based statistical shape modeling (SSM) is vital for population-level morphometric analysis, but conventional pipelines assume clean, fully registered surfaces.
By Nawazish Khan, Sanjay Bhandari, Sarang Joshi, Alzbeta Novotna, Tiffany Jeong, Loretta Bowman, Michael Hernandez, Tobi Somorin, Viraj Govani, Jesse Glodstein, Shireen Elhabian
arXiv:2607. 27154v1 Announce Type: cross Abstract: CT vision-language foundation models have demonstrated promising performance across downstream tasks, but are typically trained with whole-volume representations that dilute fine-grained anatomical signals.
By Roshan Kenia, Stephanie L McNamara, William Lotter
arXiv:2606. 03888v1 Announce Type: cross Abstract: Self-supervised learning has enabled large-scale pre-training on 2D natural images, producing general-purpose visual representations that transfer effectively across tasks.
By Ioannis Gatopoulos, Nicolas K\"anzig, Sebastian Ot\'alora, Fei Tang
arXiv:2607. 10992v1 Announce Type: cross Abstract: Perineural invasion (PNI) is a clinically relevant indicator of tumor aggressiveness and can influence surgical decision-making, motivating interest in reliable preoperative assessment.
By Youngung Han, Hyunsu Go, Kyeonghun Kim, Induk Um, Junga Kim, Jaewon Jung, Woo Kyoung Jeong, Won Jae Lee, Pa Hong, Ken Ying-Kai Liao, Hyuk-Jae Lee, Nam-Joon Kim
Sparse-view computed tomography is a severely ill-posed inverse problem, where recent 3D Gaussian Splatting methods offer an efficient explicit representation for tomographic reconstruction. However, we find that projection-domain optimization can be misleading in this setting: the rendered projections may continue to improve while the reconstructed volume deteriorates.