The paper introduces Conditional Diffusion Posterior Alignment (CDPA), a method that scales diffusion-based sparse‑view CT reconstruction to large 3D volumes by conditioning a 2D U‑Net diffusion model on an initial 3D reconstruction and enforcing data‑consistency alignment. CDPA addresses high memory demands, limited 3D training data, and slice‑wise inconsistencies, achieving state‑of‑the‑art performance on synthetic and real Cone Beam CT data. The authors also demonstrate that the same approach improves fast denoising U‑Nets, delivering near‑diffusion quality at a fraction of the computational cost.
By Luis Barba, Johannes Kirschner, Benjamin Bejar
arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
arXiv:2606. 19867v1 Announce Type: cross Abstract: Computed Tomography (CT) is essential for diagnosing pediatric craniofacial abnormalities, yet poses radiation risks to developing anatomies.
By Dong Yeong Kim, Jaewon Choi, Youmin Shin, Jungyu Lee, Myeongseop Kim, Jinwook Choi, Joo Whan Kim, Young-Gon Kim
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
The paper introduces LiftXR, a geometry‑guided framework that first reconstructs a 3D anatomical layout from bi‑planar X‑ray images and then uses this layout to guide CT volume reconstruction. An anatomical parser refines the layout by analyzing the reconstructed CT, enabling region‑specific intensity calibration. Experiments on two public datasets show LiftXR surpasses recent X‑ray‑to‑CT methods and improves downstream segmentation performance.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
arXiv:2602.08727v2 Announce Type: replace-cross
Abstract: Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utili...
By Johannes Thalhammer, Tina Dorosti, Sebastian Peterhansl, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff
arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
arXiv:2609.14312v1 Announce Type: new
Abstract: Multi-shell diffusion MRI (dMRI) unlocks more expressive microstructural modeling than single-shell scans, yet its longer acquisition time hinders depl...
By Binghua Li, Christina Andica, Tong Liang, Ziqing Chang, Chao Li, Wataru Uchida, Kaito Takabayashi, Qibin Zhao, Toshihisa Tanaka, Zhe Sun, Shigeki Aoki
arXiv:2608. 19965v1 Announce Type: cross Abstract: Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology.
By Sidi Mohamed Sid'El Moctar, Nicolas Vitry, H\'el\`ene Bouvrais
arXiv:2608. 07575v1 Announce Type: cross Abstract: Confocal microscopy of optically cleared and swelled tissue resolves complex biological structures in 3D, but such acquisitions are highly anisotropic: along the under-sampled axial direction the structure can appear discontinuous, hampering reconstruction and automated quantitative analysis.
By Arash Fatehi, Robin Ebbestad, Linus Butt, Hans Blom, Sigrid Lundberg, Hannes Olauson, Hjalmar Brismar, David Unnersj\"o-Jess, Thomas Benzing, Katarzyna Bozek
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao
arXiv:2609.10376v1 Announce Type: new
Abstract: Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is...
By Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Fr\'ed\'eric Lavoie, Herve Lombaert