arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
Noise2Match is a self‑supervised method for low‑dose CT denoising that uses an adaptive inter‑slice matching network to model and correct the label transition between adjacent slices. By ensuring the equal‑mean condition of the Noise2Noise framework, it theoretically matches supervised training with paired noisy‑clean data. The approach also extends effectively to low‑dose cone‑beam CT, outperforming existing image‑domain self‑supervised methods.
The paper introduces a deep dictionary network (DDN) foundation model designed for ultra‑low‑dose CT (ULDCT) denoising across multiple organs. By cascading convolutional sparse coding layers with iterative soft‑thresholding, the architecture offers inherent interpretability, while dynamic dictionary and threshold modules enhance representation. The model is pre‑trained on over one million normal‑dose CT images and fine‑tuned on multi‑organ ULDCT datasets, achieving state‑of‑the‑art performance that consistently outperforms existing methods.
By Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu, Huazhu Fu
arXiv:2607. 02952v1 Announce Type: cross Abstract: Convolutional Neural Networks (CNNs) achieve strong denoising performance by exploiting spatial context from neighboring pixels.
By Gihyun Kim, Jong-Seok Lee
arXiv:2508.17299v2 Announce Type: replace
Abstract: Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despi...
By Zhihao Chen, Qi Gao, Zilong Li, Junping Zhang, Yi Zhang, Jun Zhao, Hongming Shan
arXiv:2601.14180v5 Announce Type: replace
Abstract: Self-supervised learning has been increasingly investigated for low-dose computed tomography (LDCT) image denoising, as it alleviates the dependenc...
By Yichao Liu, Zongru Shao, Rui Wen, Yueyang Teng, Junwen Guo
The paper introduces a physics‑driven, cross‑domain iterative framework for self‑supervised low‑dose CT denoising. It first uses a learned sinogram prior and the LDCT noise model to separate Poisson and Gaussian noise components, then applies binomial and Gaussian data thinning to create two training pairs with independent noise realizations. These pairs train an image‑domain network whose outputs are forward‑projected to refine the prior, yielding consistent performance gains over existing self‑supervised baselines and comparable results to supervised methods.
By Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
arXiv:2507. 06764v5 Announce Type: replace-cross Abstract: In this work, we propose Fast Equivariant Imaging (FEI), a novel unsupervised learning framework to rapidly and efficiently train deep imaging networks without ground-truth data.
By Guixian Xu, Jinglai Li, Junqi Tang
arXiv:2602.08727v2 Announce Type: replace-cross
Abstract: Undersampled CT volumes minimize acquisition time and radiation exposure but introduce artifacts degrading image quality and diagnostic utili...
By Johannes Thalhammer, Tina Dorosti, Sebastian Peterhansl, Daniela Pfeiffer, Franz Pfeiffer, Florian Schaff
arXiv:2608.13791v2 Announce Type: replace-cross
Abstract: Positron emission tomography (PET) imaging suffers from limited spatial resolution and low signal-to-noise ratio, which can compromise quanti...
By Boxiao Yu, Savas Ozdemir, Yang Xing, Fumio Hashimoto, Jiong Wu, Yizhou Chen, Axel Rominger, Ruogu Fang, Kuangyu Shi, Tinsu Pan, Kuang Gong
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
Most existing deep learning-based PET image denoising methods assume a fixed and known dose reduction factor (DRF) for low-dose PET images. However, these methods encounter significant performance degradation when the DRF varies beyond the assumed one in practical applications.