Hugging Face Trending Papers

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

Read the original on Hugging Face Trending Papers →

Noise2Match is a self‑supervised method for low‑dose CT denoising that uses an adaptive inter‑slice matching network to model and correct the label transition between adjacent slices. By ensuring the equal‑mean condition of the Noise2Noise framework, it theoretically matches supervised training with paired noisy‑clean data. The approach also extends effectively to low‑dose cone‑beam CT, outperforming existing image‑domain self‑supervised methods.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at Hugging Face Trending Papers.

arXiv Computer Vision
Sep 3

Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising

The paper introduces a physics‑driven, cross‑domain iterative framework for self‑supervised low‑dose CT denoising. It first uses a learned sinogram prior and the LDCT noise model to separate Poisson and Gaussian noise components, then applies binomial and Gaussian data thinning to create two training pairs with independent noise realizations. These pairs train an image‑domain network whose outputs are forward‑projected to refine the prior, yielding consistent performance gains over existing self‑supervised baselines and comparable results to supervised methods.

By Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
arXiv AI
Jul 31

PatchDenoiser: Parameter-efficient multi-scale patch learning and fusion denoiser for Low-dose CT imaging

arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.

By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
arXiv Machine Learning
Jul 15

GenDiff: A Dose and Anatomy Aware Diffusion Model with Structural Prior Refinement for Low-Dose CT Reconstruction and Generalization

arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.

By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman