arXiv:2601.14180v5 Announce Type: replace
Abstract: Self-supervised learning has been increasingly investigated for low-dose computed tomography (LDCT) image denoising, as it alleviates the dependenc...
By Yichao Liu, Zongru Shao, Rui Wen, Yueyang Teng, Junwen Guo
The paper introduces a physics‑driven, cross‑domain iterative framework for self‑supervised low‑dose CT denoising. It first uses a learned sinogram prior and the LDCT noise model to separate Poisson and Gaussian noise components, then applies binomial and Gaussian data thinning to create two training pairs with independent noise realizations. These pairs train an image‑domain network whose outputs are forward‑projected to refine the prior, yielding consistent performance gains over existing self‑supervised baselines and comparable results to supervised methods.
By Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
arXiv:2508.17299v2 Announce Type: replace
Abstract: Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despi...
By Zhihao Chen, Qi Gao, Zilong Li, Junping Zhang, Yi Zhang, Jun Zhao, Hongming Shan
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
arXiv:2608.10343v2 Announce Type: replace
Abstract: While deep learning-based denoising has become widely adopted in low-dose CT, conventional models use generic architectures designed for natural im...
By Minwoo Yu, N. Robert Bennett, Jongduk Baek, Adam S. Wang
X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete. While learned reconstruction methods such as the Learned Primal-Dual algorithm achieve strong performance, they typically rely on supervised training with access to ground-truth data, which is often unavailable in practice.
The paper introduces a deep dictionary network (DDN) foundation model designed for ultra‑low‑dose CT (ULDCT) denoising across multiple organs. By cascading convolutional sparse coding layers with iterative soft‑thresholding, the architecture offers inherent interpretability, while dynamic dictionary and threshold modules enhance representation. The model is pre‑trained on over one million normal‑dose CT images and fine‑tuned on multi‑organ ULDCT datasets, achieving state‑of‑the‑art performance that consistently outperforms existing methods.
By Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu, Huazhu Fu
arXiv:2608. 08919v1 Announce Type: cross Abstract: During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose.
By Alzahra Altalib, Chunhui Li, Christopher Hamill Taylor, Sankar Pillai, Alessandro Perelli
arXiv:2606. 26991v1 Announce Type: cross Abstract: X-ray computed tomography reconstruction is an ill-posed inverse problem, particularly in low-dose and sparse-angle settings where measurements are noisy and incomplete.
By Antti S\"allinen, Siiri Rautio, Santeri Kaupinm\"aki, Andreas Hauptmann
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv:2603.25869v2 Announce Type: replace-cross
Abstract: Self-supervised image denoising methods have traditionally relied on architectural constraints, pseudo-pair constructions, or specialized los...
By Brayan Monroy, Jorge Bacca, Juli\'an Tachella