arXiv Computer Vision

ConRef: Auditing Reference Reliability in 2D/3D Registration Benchmarks

ConRef is a multi‑view framework that audits reference poses in 2D/3D registration benchmarks by jointly analyzing multiple X‑ray observations to estimate an additional reference pose, quantify its uncertainty, and detect outliers. In validation on a bead‑based phantom dataset, ConRef’s estimates differed from independent references by only 0.08–0.12 mm, whereas discrepancies with the original references reached 2.06 mm on a femur dataset. The method also flagged 22 DeepFluoro X‑rays as potential outliers and showed that reference choice could alter sub‑millimeter success conclusions for the same registrations.

arXiv Computer Vision
Oct 16

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

The paper presents a clinically viable pipeline that uses routine intraoperative C‑arm fluoroscopy to derive per‑vertebra 6‑DoF poses, which are co‑registered to an RGB‑D camera via a multimodal fiducial array. This approach provides independent subsurface ground truth for validating markerless spinal tracking methods without adding radiation or altering standard surgical workflows. Ex vivo tests show an end‑to‑end accuracy of about 2 mm and 3.3°, and the framework is applied to evaluate two markerless registration strategies on real surgical data.

By Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
arXiv Machine Learning
Nov 16

A thorough review on Deep Learning approaches to 2D-to-3D Registration in Medical Imaging

This review surveys deep learning methods for 2D‑to‑3D medical image registration, a critical step for aligning preoperative 3D volumes with real‑time 2D images during surgery. It analyzes 41 studies, noting that direct regression pipelines dominate, hybrid CNN‑attention architectures are emerging, and most work focuses on X‑ray‑to‑CT registration. The paper highlights gaps such as lack of per‑case uncertainty estimation and limited temporal modeling, suggesting state‑space models and foundation‑model integration as future directions.

By Andrea Borghesi, Julia van Beurden, Maarten van Alphen, Michiel van den Brekel, Luc Karssemakers, Jan-Jakob Sonke, Baris Karakullukcu, Jonas Teuwen, George Yiasemis
arXiv Computer Vision
Aug 26

C3VDReg: A Benchmark for Local-to-Local Colonoscopic Registration toward Anatomical Localization

C3VDReg is a benchmark for local-to-local colonoscopic registration that uses the Colonoscopy 3D Video Dataset (C3VD) to generate 10,015 partial-to-partial point cloud pairs, with 2,088 held‑out test pairs. Each pair consists of a source point cloud from depth reprojection and a target point cloud from CT mesh raycasting, evaluated under a standardized protocol of 8,192 points per cloud and fixed pose conventions. Experiments show that high geometric overlap does not guarantee reliable pose recovery, revealing translation ambiguity along repetitive tubular anatomy as a key failure mode.

By Linzhe Jiang, Jiayuan Huang, Sophia Bano, Matthew J. Clarkson, Zhehua Mao, Mobarak I. Hoque
arXiv Computer Vision
Nov 6

CUFormer: Modality-Aware CT-Ultrasound Point Cloud Registration for Orthopedic Navigation

CUFormer is a modality-aware registration framework that aligns intraoperative ultrasound (US) bone-surface point clouds with preoperative computed tomography (CT) models, addressing challenges from differing imaging physics and partial surface coverage. It introduces a Modality-Aware Transformer (MAT) that encodes modality through identity embeddings and uses modality-specific adapters within a shared geometric matcher, while modeling imaging visibility to weight correspondences. On two CT-US datasets (UltraBones100k and UltraBonesHip) and the CT-RGB-D SpineDepth dataset, CUFormer achieves the lowest mean registration errors, notably reducing RMSE by 65.8% on UltraBones100k compared to the best baseline.

By Lixing Tan, Hongye Hao, Tianrun Gu, Qing Xia, Yuting Guo, Shuai Li, Aimin Hao
arXiv Computer Vision
Sep 25

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

The paper examines how residual misalignments from registration procedures introduce structured label noise in supervised synthetic CT (sCT) generation. It shows that voxel‑wise metrics are heavily influenced by the consistency between training and evaluation registrations, and that training with anatomically consistent registrations reduces variability and improves robustness. Introducing a perceptual loss based on a pretrained Segment Anything encoder yields sharper, more anatomically coherent sCT and highlights the need for anatomy‑oriented evaluation.

By Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
arXiv Computer Vision
Oct 22

XGLASS: X-Ray, Gaze and Language Assisted Slice Sequencing for CT Volumes

XGLASS is a method that transfers expertise from 2D X‑ray vision‑language models to 3D CT volumes by using disease‑conditioned importance maps derived from radiologist gaze on X‑rays. By aligning these gaze priors with coronal CT projections, XGLASS predicts a disease‑specific ordering of axial slices, prioritizing diagnostically relevant slices. The approach achieves a top‑10 hit rate of up to 75.9% on a 240‑slice scan and reduces downstream model calls by 87.5% while improving F1 scores, making it a lightweight preselector for volumetric CT analysis.

By Michael Gl\"ockler, Timo Ropinski
arXiv Computer Vision
Sep 14

Spectral Consistency-Guided Multiview Point Cloud Registration for Low-Overlap Scenes

The paper introduces GMPCR, a non‑learning spectral consistency‑guided framework for multiview point cloud registration in low‑overlap scenes. GMPCR refines initial correspondences into a second‑order compatibility structure, uses spectral analysis to filter unreliable matches and select informative scan pairs, and then applies maximal‑clique hypothesis generation for robust relative transformations. The resulting sparse pose graph is further refined with an adaptive history‑aware synchronization scheme, and a recovery mechanism allows previously down‑weighted edges to regain confidence, achieving high registration recalls on benchmark datasets while reducing computational cost.

By Tianyu Li, Yanghong Lin, Shudong Zhou, Kui Yang, Jingru Zhang, Li Fang, Wei Yao