arXiv Computer Vision

SynSeq: End-to-End SYNTAX Score Prediction from Coronary Angiography Videos

SynSeq is a video‑based method that directly predicts the SYNTAX score from coronary angiography videos, using targeted preprocessing and a zero‑inflation‑aware loss with linear target scaling. On the CardioSyntax dataset it outperforms prior state‑of‑the‑art approaches, improving $R^2$ by 0.55, reducing prediction bias by 93.1%, and delivering consistent performance across three expert graders. The model also achieves a weighted $F_1$‑score of 0.80 for revascularization treatment recommendations, approaching inter‑expert agreement.

arXiv Computer Vision
4d ago

CAG-VLM: Fine-Tuning of a Large-Scale Model to Recognize Angiographic Images for Next-Generation Diagnostic Systems

The paper presents CAG‑VLM, a fine‑tuned vision‑language model designed to interpret coronary angiography (CAG) images. A two‑stage pipeline first annotates 14,686 frames from 539 exams for key‑frame detection and laterality, achieving 0.96 F1 with a ConvNeXt‑Base CNN. The annotated data is then used to fine‑tune three open‑source VLMs via LoRA; Gemma3 w/LoRA receives the highest clinician rating (mean 7.20/10) and is designated as CAG‑VLM, demonstrating that specialized VLMs can aid cardiologists in generating reports and treatment recommendations from CAG images.

By Yuto Nakamura, Satoshi Kodera, Haruki Settai, Hiroki Shinohara, Masatsugu Tamura, Tomohiro Noguchi, Tatsuki Furusawa, Ryo Takizawa, Tempei Kabayama, Norihiko Takeda
arXiv AI
1d ago

A Multi-Center Dataset and Benchmark for SYNTAX Segmentation of Coronary Angiograms

The paper introduces CARDIAG, a multi‑center benchmark dataset for fine‑grained SYNTAX segmentation of coronary angiograms, featuring highly imbalanced multi‑class labels, catheter and stenosis masks, expert uncertainty maps, temporal frames, and spatial metadata. The authors conduct an extensive architectural sweep of 24 models—including CNNs, Vision Transformers, and State‑Space Models—using advanced metrics such as clDice, vessel diameter error, and uncertainty error‑detection. Their findings show that large‑kernel CNNs (ConvNeXt V2 with DeepLabV3+) outperform recent ViTs and SSMs, achieving a Dice score of 0.456, which improves to 0.479 with model ensembling, while also exploring out‑of‑distribution generalization through leave‑one‑center‑out cross‑validation.

By Dominik Bernard Lau, Jerzy Szyjut, Hubert Malinowski, Adam Brzeski, Tomasz Dziubich, Natalia Zieli\'nska, Tomasz Figatowski, Rados{\l}aw Targo\'nski
arXiv Machine Learning
Jul 27

CARDIAG: A Dense Segment Classification Benchmark of Deep Learning Architectures for Coronary Angiography

arXiv:2607. 22139v1 Announce Type: cross Abstract: Accurate pixel-level classification of coronary angiograms is critical for cardiovascular disease assessment, yet the field lacks standardized evaluation protocols.

By Dominik Bernard Lau, Hubert Malinowski, Jerzy Szyjut, Adam Brzeski, Tomasz Dziubich, Rados{\l}aw Targo\'nski, Tomasz Figatowski, Natalia Zieli\'nska
arXiv Computer Vision
Oct 9

BiomedXPro: Prompt Optimization for Explainable Diagnosis with Biomedical Vision Language Models

BiomedXPro is an evolutionary framework that uses a large language model to automatically generate a diverse set of interpretable, natural‑language prompt pairs for disease diagnosis with biomedical vision‑language models. It addresses the lack of transparency in existing prompt optimization methods by producing prompts that are both understandable and aligned with clinically significant features. Experiments on multiple biomedical benchmarks show that BiomedXPro outperforms state‑of‑the‑art prompt‑tuning techniques, especially in few‑shot, data‑scarce scenarios.

By Kaushitha Silva, Mansitha Eashwara, Sanduni Ubayasiri, Ruwan Tennakoon, Damayanthi Herath
arXiv Computer Vision
Sep 14

A Dual Cross-Attention Framework for Colposcopic CIN Grading and Swede Score Prediction Using a New Multi-Center Dataset

The paper introduces a dual cross‑attention deep learning framework for automated grading of Cervical Intraepithelial Neoplasia (CIN) and prediction of Swede scores, using a newly released BUET Multi‑Center Colposcopy Dataset. The architecture fuses paired multimodal cervigrams and employs a custom composite loss to handle class imbalance, achieving 71.85% accuracy and 86.23% AUC‑ROC for three‑class CIN grading, and AUC‑ROC values between 75.7% and 88.4% for individual Swede score components. The total predicted Swede Score has a mean absolute error of 1.489, indicating potential for AI‑assisted colposcopy screening in resource‑limited settings.

By Dania Khan, Nuzhat Aisha Shaikh, Asfina Hassan Juicy, Raiyun Kabir, S M Shahida, Taufiq Hasan
arXiv AI
Aug 7

ECG-LENS: Lead-Aware Clinical Context Enriched ECG Report Generation and Evaluation

arXiv:2608. 05893v1 Announce Type: new Abstract: Electrocardiography (ECG) is one of the most widely used non-invasive tools for diagnosing cardiovascular disease, but transforming multi-lead ECG recordings into reliable clinical reports remains challenging.

By Akanta Das, Tasinul Islam Ahon, Ahmed Mahir Sultan Rumi, Md Mahbubur Rahman, Tausif Amim Shadly, Tanzima Hashem
arXiv AI
Nov 14

Fine-Tuned Small Language Model for Synthetic Clinical Data Generation and Predictive Healthcare Analytics

The paper presents a method for augmenting limited medical datasets using a fine‑tuned Microsoft Phi‑2 small language model (SLM). The SLM was adapted to the medical domain via supervised fine‑tuning on the MedQuad dataset, QLoRA, and few‑shot prompting, and then used to generate synthetic vital‑sign records. Experiments show that the fine‑tuned SLM outperforms the pretrained model on lexical and semantic metrics and that synthetic data augmentation improves an LSTM predictor’s accuracy from 89.0% to 93.7%, with gains in precision, recall, and F1‑score.

By Mihnea Sebastian Burlacu, Ionut Anghel, Tudor Cioara
arXiv AI
Sep 18

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

The paper introduces a physics-informed deep learning framework that reconstructs 3D coronary geometry from dual-view angiography and predicts velocity and pressure fields using a decoupled network with embedded physical priors. Across 32 patients and four flow conditions, the model achieved a trans‑stenotic pressure‑drop error of 2.02% and velocity/pressure relative‑L2 errors of 0.054 and 0.023, respectively, while matching hospital‑measured FFR with 93.8% diagnostic accuracy. The pipeline completes the full angiography‑to‑hemodynamics conversion in about 20 minutes per patient and supports sparse‑data assimilation for revascularization planning.

By Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye, Qiang Luo, Mao Chen, Wenqi Hu