arXiv:2607. 02569v1 Announce Type: cross Abstract: This paper presents a safety-centered empirical evaluation of uncertainty-aware last-layer adaptation for referable diabetic retinopathy screening using RETFound, a self-supervised vision-transformer retinal foundation model used here as a frozen feature encoder, and the public APTOS 2019 and DDR diabetic retinopathy fundus image datasets.
By Karim Mardhani
arXiv:2610.33965v1 Announce Type: new
Abstract: Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on ac...
By Akwasi Asare
The study evaluates EfficientNet variants B0–B7 for classifying retinal diseases from spectral-domain optical coherence tomography (SD‑OCT) images at a fixed 224×224 resolution. Eight ImageNet‑pretrained models were tested on the Kermany dataset, with training involving a frozen‑backbone head followed by partial fine‑tuning. Results show non‑monotonic accuracy, with B1 achieving the highest overall accuracy (96.95%) and best Drusen F1, while B7 offered a secondary accuracy gain at the cost of larger model size and CPU latency.
By Shkelqim Sherifi
SafeRestore introduces a framework for certifying when an industrial image restoration should be automatically returned to a detector or require human review. It ranks five restoration candidates using action‑specific fitted scores, selects a threshold gate on tuning data, and evaluates the gate on a separate certification sample with two one‑sided exact binomial bounds—one for evidence‑loss incidents and one for excess‑activation incidents. In a retrospective study of 4,591 Carinthia‑S images, the protocol demonstrates auditable risk‑coverage behavior, with varying pass rates across different policies and morphologies.
By Shaoliang Yang, Jun Wang
The paper introduces a decision‑aware evaluation protocol for medical image segmentation uncertainty that separates uncertainty estimation from deferral policy and assesses their joint performance under fixed review budgets. It reports metrics such as fixed‑budget error reduction, risk‑coverage behavior, region‑level review proxies, structural failure modes, and sensitivity to review assumptions. Experiments on retinal vessel, skin lesion, and polyp segmentation with various backbones and uncertainty estimators show that estimator rankings vary with review unit, uncertainty target, and cost model, and that boundary and thin‑structure failures are partly due to annotation ambiguity.
By Saket Maganti, Shreyank N Gowda
arXiv:2608.22059v1 Announce Type: cross
Abstract: Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited....
By Xingtao Lin, Hangqi Ren, Caiwan Sun, You Chen
arXiv:2606. 08123v2 Announce Type: replace-cross Abstract: Model selection for safety-relevant visual recognition is often based on clean aggregate performance, although robustness, transfer, embedded latency, and explanation faithfulness may produce different preferences.
By Ruben Dario Florez-Zela
ReuScope is a protocol designed to audit data reuse and evaluation sensitivity, demonstrated on Capsule Vision 2024. It measures data relationships and compares model performance when altering the evaluation population or training data while keeping predictions constant. The study finds that removing training rows linked to Kvasir-Capsule significantly lowers public‑validation accuracy, indicating sensitivity to source removal rather than leakage inflation.
By Eunseob Choi, Kyeonghun Kim, Hyuk-Jae Lee, Nam-Joon Kim
arXiv:2605. 14108v2 Announce Type: replace-cross Abstract: Diabetic Retinopathy (DR) is one of the leading causes of preventable blindness, and automated screening can help extend specialist capacity in resource-constrained clinical workflows.
By Nishi Doshi, Shrey Shah
CalibCause is a quality‑gated, interpretable deep learning framework for diabetic retinopathy grading that integrates visual explanations, label‑free image‑quality conditioning, knowledge distillation, and calibrated confidence with deferral. Using 51,310 fundus images from multiple datasets, the distilled student model achieved a quadratic weighted kappa of 0.863 and accuracy of 0.865 on pooled testing, while maintaining comparable performance across held‑out environments. The framework also demonstrated improved calibration (expected calibration error 0.025–0.036) and higher accuracy (up to 0.923) when deferring the least confident 20% of images.
By Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin
arXiv:2607. 01973v1 Announce Type: cross Abstract: Vision-Language Models (VLMs) are increasingly applied in medical tasks such as pathology description, report generation, and visual question answering.
By Sofiane Ouaari, Kevin Vorwalder, Nico Pfeifer
arXiv:2608. 16198v1 Announce Type: cross Abstract: Dermatology models face distribution shifts in teledermatology settings, where submitted images differ from the training data in lighting, angle, distance, focus, and framing.
By Fabian Gr\"oger, Marco Weishaupt, Philippe Gottfrois, Simone Lionetti, Linda Wermelinger, Nipun Ranasekara, Ludovic Amruthalingam, Alexander A. Navarini, Marc Pouly