arXiv Computer Vision
4d ago

With foundation-model features, aggregator complexity does not improve cross-hospital discrimination in gastric whole-slide image classification

The study evaluated whole‑slide image classifiers for gastric cancer across five Korean hospitals, using foundation‑model features and leave‑one‑hospital‑out validation. A hierarchical patch‑region‑slide graph aggregator (CHIME‑MIL) with site alignment and two‑scale fusion achieved a mean AUC of 0.837, outperforming six conventional attention and transformer aggregators that lacked these steps. However, when matched with the same alignment and fusion, CHIME‑MIL did not surpass simple attention‑based pooling, and global max pooling performed best (AUC 0.855). The alignment step, which subtracts each hospital’s mean feature vector without labels, enabled onboarding of a new hospital from only ten unlabeled slides but yielded only a modest 0.002 AUC improvement, and the model’s accuracy gains were inconsistent. "whyItMatters":"The findings show that adding complex aggregation methods does not necessarily improve cross‑hospital discrimination, highlighting the importance of simpler, label‑free onboarding and calibration checks for deployable pathology systems."

By Nheng Vanchhay, Ali Hussain, Khan Ziaullah, Moon-Il Joo, Md Ariful Islam Mozumder, Rashedul Islam Sumon, Won-Ae Lee, Min-Sun Cho, Hyeong-Chan Shin, Yujun Park, Baek Hwan Cho, Nam-Hoon Cho, Heejung An, Heung-Kook Choi, Haeyoun Kang, Hyunki Kim, Hee Cheol Kim
arXiv AI
1d ago

Within-Family EfficientNet Scaling under Fixed-Resolution Transfer Learning for Spectral-Domain Optical Coherence Tomography Retinal Disease Classification

The study evaluates EfficientNet variants B0–B7 for classifying retinal diseases from spectral-domain optical coherence tomography (SD‑OCT) images at a fixed 224×224 resolution. Eight ImageNet‑pretrained models were tested on the Kermany dataset, with training involving a frozen‑backbone head followed by partial fine‑tuning. Results show non‑monotonic accuracy, with B1 achieving the highest overall accuracy (96.95%) and best Drusen F1, while B7 offered a secondary accuracy gain at the cost of larger model size and CPU latency.

By Shkelqim Sherifi
arXiv Computer Vision
Sep 22

Comparative Performance and Parameter-Efficient Adaptation of DINOv2 for Active Trachoma Classification

The study evaluates the performance of the DINOv2 visual representation for classifying Trachomatous Inflammation-Follicular (TF) versus normal conjunctival images. Using 1,546 images processed by the OPTED pipeline, the authors compare six pretrained backbones and then test four lightweight adaptation methods on DINOv2 ViT-B/14. The best results—91.66% accuracy, 90.69% macro‑F1, and 96.06% AUC—were achieved with DINOv2 plus Efficient Channel Attention (ECA) and a focal‑plus‑center loss, though ECA’s benefit varied with the loss function.

By Kibrom Gebremedhin, Hadush Hailu, Bruk Gebregziabher, Yordanos Hailu
arXiv Computer Vision
Sep 7

MultiAttenGastro: Multi-Dimensional Attention Augmentation for Gastrointestinal Endoscopy Classification

MultiAttenGastro is a plug‑and‑play attention framework that adds parallel 1‑D channel, 2‑D spatial, and 3‑D contextual heads to existing CNN and transformer backbones for gastrointestinal endoscopy classification. Across eight backbones and five public GI datasets, the framework improves performance on large‑gap datasets such as Kvasir‑Capsule but shows no benefit on small‑gap benchmarks like Kvasir‑v2, with mixed results elsewhere. Analysis using Centered Kernel Alignment indicates that the gains are linked to representational redundancy: low inter‑head redundancy under large domain gaps yields consistent improvements, while high redundancy under small gaps leads to losses.

By Sadhana Devarajan, Praveen Kumar Chandaliya, Dhruvin Jashvant Kumar Shah, Kishor Upla, Kiran Raja