arXiv:2611.26914v1 Announce Type: new
Abstract: Deploying generative AI agents in enterprise clinical workflows requires enforcing multi-dimensional safety and compliance policies--preventing HIPAA P...
By Joshua Broyde, Sarita A. Joshi
arXiv:2607. 02569v1 Announce Type: cross Abstract: This paper presents a safety-centered empirical evaluation of uncertainty-aware last-layer adaptation for referable diabetic retinopathy screening using RETFound, a self-supervised vision-transformer retinal foundation model used here as a frozen feature encoder, and the public APTOS 2019 and DDR diabetic retinopathy fundus image datasets.
By Karim Mardhani
CalibCause is a quality‑gated, interpretable deep learning framework for diabetic retinopathy grading that integrates visual explanations, label‑free image‑quality conditioning, knowledge distillation, and calibrated confidence with deferral. Using 51,310 fundus images from multiple datasets, the distilled student model achieved a quadratic weighted kappa of 0.863 and accuracy of 0.865 on pooled testing, while maintaining comparable performance across held‑out environments. The framework also demonstrated improved calibration (expected calibration error 0.025–0.036) and higher accuracy (up to 0.923) when deferring the least confident 20% of images.
By Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin
arXiv:2610.33965v1 Announce Type: new
Abstract: Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on ac...
By Akwasi Asare
arXiv:2603.26483v2 Announce Type: replace
Abstract: Medical edge-AI systems must operate under a difficult tension: delivering reliable diagnostic inference while running on devices with limited batt...
By Mostafa Anoosha, Dhavalkumar Thakker, Kuniko Paxton, Koorosh Aslansefat, Bhupesh Kumar Mishra, Baseer Ahmad, Rameez Raja Kureshi
The study compares five deep‑learning models—Nested U‑Net, ResU‑Net, nnUnet, Swin‑Unet, and MedSegDiff—plus a classical thresholding baseline for segmenting geographic atrophy (GA) in en‑face OCT images. Using a dataset of 269 OCT volumes from two devices (Cirrus and Spectralis) and a three‑step preprocessing pipeline, nnUnet achieved the highest Dice similarity coefficient (0.8882 ± 0.0033) on a held‑out validation set. The other models scored lower, with Dice values ranging from 0.6886 to 0.8453.
Why it matters: The results show that nnUnet offers the most reliable performance for GA segmentation in en‑face OCT, providing a better balance of accuracy, stability, and efficiency under limited data conditions.
By Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori, Nicola Valsecchi, Nasiq Hasan, Elham Sadeghi, Jos\`e-Alain Sahel, Jay Chhablani, Kiran Kumar Vupparaboina, Sandeep Chandra Bollepalli