Universal BCI Personalization: One API for Frozen EEG Trunks and Foundation Models
arXiv:2607. 22397v1 Announce Type: cross Abstract: Frozen EEG encoders proliferate; per-model fine-tune defaults do not scale.
The paper investigates when a deployed motor‑imagery (MI) brain‑computer interface (BCI) decoder should allocate adaptation resources. It proposes a resource‑priced ladder of adaptation layers—factory, Bayesian head, affine map, and full fine‑tune—controlled by regime‑aware gating that balances accuracy, fit time, and label cost. Experiments show that adaptive gating reduces unnecessary adaptation on clean data, lightweight heads can match or surpass frozen trunks under stress, and that adaptation severity varies across datasets, underscoring the need for dynamic control.
arXiv:2607. 22397v1 Announce Type: cross Abstract: Frozen EEG encoders proliferate; per-model fine-tune defaults do not scale.
ThinkNet is a validation‑controlled framework that uses train‑only normalization, evolutionary search guided by validation, and validation‑gated inference to build compact motor‑imagery EEG decoders that generalize to unseen subjects. In a fixed benchmark on the BCI Competition IV‑2a dataset, the best single model achieved 44.35 % accuracy with only 4.9 k parameters, while a compact ensemble of six families reached 43.31 % accuracy. Across a broader search, models with ≤25 k parameters outperformed larger ones after retraining, but validation reliability remains a bottleneck under subject shift.
arXiv:2606. 09189v1 Announce Type: cross Abstract: EEG foundation-model releases are usually audited one endpoint at a time: raw-reconstruction, membership inference, identity linkage, or DP-SGD on the downstream head.
arXiv:2607. 11950v1 Announce Type: cross Abstract: Brain field potentials are scale-free: their power spectra follow a $1/f^{\beta}$ law whose aperiodic exponent $\beta$ tracks cortical state, and sleep depth in particular is a shift in $\beta$.
EEG foundation-model releases are usually audited one endpoint at a time: raw-reconstruction, membership inference, identity linkage, or DP-SGD on the downstream head. We audit the same released embeddings under all four endpoints jointly, on BIOT, LaBraM, and EEGPT, and show that each single-endpoint audit clears releases that still leak spectral attributes.
arXiv:2607. 11950v2 Announce Type: replace-cross Abstract: Brain field potentials are scale-free: their power spectra follow a $1/f^{\beta}$ law whose aperiodic exponent $\beta$ tracks cortical state, and sleep depth in particular is a shift in $\beta$.
The paper investigates the limitations of using balanced accuracy as an aggregate metric for neural‑signal decoding when test‑time adaptation is applied. It shows that balanced accuracy can mask the disappearance of a class—e.g., a one‑class decoder can achieve the same score as a model predicting both classes at 50%—and that class‑level changes are not captured by the aggregate. The authors recommend reporting both class‑level and subject‑level changes alongside the aggregate metric to avoid hidden harms.
Parameter-efficient fine-tuning is usually framed as a question of how many parameters to update. Under a severe trainable-state budget, however, where those coefficients act is equally consequential....
The paper introduces GALA, a label‑free calibration method for EEG‑based visual decoding that aligns unlabeled EEG embeddings to a known gallery of images using shrinkage whitening, hubness correction, and Sinkhorn–Procrustes alignment. In an incremental transductive calibration setting, GALA improves top‑1 accuracy on the THINGS‑EEG‑2 benchmark from 28% to 67% for a new subject over 53 minutes of use, outperforming other methods across diverse evaluation scenarios. The method relies on accumulating unlabeled EEG data and known outcome candidates, making it suitable for practical brain‑computer interface deployments.
arXiv:2609.00762v1 Announce Type: new Abstract: Parameter-efficient fine-tuning is usually framed as a question of how many parameters to update. Under a severe trainable-state budget, however, where...
arXiv:2607. 24519v2 Announce Type: replace Abstract: Pretrained EEG foundation models are proposed for clinical decoding, but whether reported gains transfer across populations or survive negative controls is unclear.
arXiv:2609.23924v1 Announce Type: new Abstract: Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree ab...