arXiv:2609.23924v1 Announce Type: new
Abstract: Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree ab...
By Kevin Zhou, Sparsh Roy
arXiv:2606. 08594v1 Announce Type: new Abstract: Deep learning EEG denoising architectures have scaled from tens of thousands to tens of millions of parameters, yet no prior study has isolated model capacity as the experimental variable or tested whether reconstruction metrics predict downstream neural-signal utility.
By Jasmeet Singh Bindra, Siddharth Panwar, Shubhajit Roy Chowdhury
arXiv:2608.03176v2 Announce Type: replace
Abstract: Imagined handwriting offers a temporally rich paradigm for non-invasive neural decoding, yet reliable recognition across unseen participants remain...
By Xiao Fan, Hongbin Guo, Yubo Han, Yi Zhang
BRIDGE-EEG is an efficient multi‑task EEG classification pipeline that leverages self‑supervised pretraining while dramatically reducing model size. It maps heterogeneous EEG recordings to a unified 62‑channel time‑frequency representation, pretrains an SE‑ResNet18 teacher with SimCLR, and distills it into smaller SE‑ResNet8 and SE‑ResNet4 students. The compact models achieve accuracy comparable to or better than larger foundation models on abnormality detection and emotion recognition, and they consume up to three times less energy on edge devices, enabling deployment on wearable hardware.
By Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
arXiv:2606. 24394v1 Announce Type: cross Abstract: Electroencephalography (EEG) is the dominant non-invasive modality for brain-computer interfaces (BCIs), yet reliable decoding of motor imagery is hampered by inter- and intra-individual variability.
By Xavier Vasques, Paul Barbaste, Olivier Oullier
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
arXiv:2607. 22733v1 Announce Type: cross Abstract: We investigate whether a generative model can supply useful synthetic motor-imagery (MI) electroencephalography (EEG) trials that improve the accuracy of independent downstream classifiers.
By Matei Moldoveanu, Alain Sirois, Claire Ben Ali, Fabien Lotte, Florian Yger
arXiv:2607. 03094v1 Announce Type: new Abstract: Electroencephalography (EEG) decoding for brain-computer interfaces (BCIs) faces a major challenge: substantial inter-subject variability limits effective cross-subject generalization.
By Aymen Sarhane, Fouad Lbakali, Mouad Souissi, Jonathan Lys, Giulia Lioi
The study evaluates how low‑precision compression affects adversarial robustness in EEG decoders used for brain‑computer interfaces. Using BCI Competition IV‑2a data, the authors compare 32‑bit floating‑point models (EEGNet and ShallowConvNet) with models pruned to 50 % and quantized to INT8 via post‑training quantization (PTQ) or quantization‑aware training (QAT). Results show that accuracy‑preserving compression does not improve direct robustness—PGD attack accuracy remains 22–24 % across all variants—yet pruning reduces bidirectional transfer efficiency more than PTQ, indicating that robustness, transferability, and deployment efficiency are distinct properties of compressed EEG decoders.
By Saim Rehman, Muhammad Shafique
arXiv:2607. 11530v1 Announce Type: new Abstract: Decoding continuous three-dimensional (3D) motor imagery (MI) using non-invasive electroencephalography (EEG)-based brain--computer interfaces (BCIs) remains challenging due to signal variability and residual decoding errors.
By Jiamian Li, Niall McShane, Attila Korik, Naomi du Bois, Karl McCreadie, Leen Jabban, Benjamin Metcalfe, \"Ozg\"ur \c{S}im\c{s}ek, Damien Coyle
The paper introduces FRIST, a two‑stage EEG decoding framework that uses fMRI data to learn spectral projections and class geometry, then refines EEG predictions. In experiments with 12 participants, FRIST improves finger‑level motor decoding accuracy across both movement execution and motor imagery tasks, outperforming EEG‑only baselines and generalizing across different EEG backbones. The method demonstrates that fMRI’s spatial resolution can enhance noninvasive EEG‑based BCI performance.
By Jintao Zhang, Yidan Ding, Joshua Kosnoff, Maxim Karrenbach, Hanwen Wang, Bin He
arXiv:2607. 22778v1 Announce Type: cross Abstract: Robust EEG motor imagery decoding remains limited by strong inter-individual variability, making it difficult to identify pipelines that generalize across users.
By Paul Barbaste, Olivier Oullier, Xavier Vasques