arXiv Machine Learning

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

arXiv AI
Oct 12

ThinkNet: Evolutionary Deep Ensembles for Efficient Motor-Imagery EEG Classification

ThinkNet is a validation‑controlled framework that uses train‑only normalization, evolutionary search guided by validation, and validation‑gated inference to build compact motor‑imagery EEG decoders that generalize to unseen subjects. In a fixed benchmark on the BCI Competition IV‑2a dataset, the best single model achieved 44.35 % accuracy with only 4.9 k parameters, while a compact ensemble of six families reached 43.31 % accuracy. Across a broader search, models with ≤25 k parameters outperformed larger ones after retraining, but validation reliability remains a bottleneck under subject shift.

By Abdul Basit, Saim Rehman, Muhammad Shafique
arXiv Machine Learning
Jun 9

How Much Capacity Does EEG Denoising Need? Ultra-Compact Networks reveal Benchmark Saturation and Metric-Utility Gap

arXiv:2606. 08594v1 Announce Type: new Abstract: Deep learning EEG denoising architectures have scaled from tens of thousands to tens of millions of parameters, yet no prior study has isolated model capacity as the experimental variable or tested whether reconstruction metrics predict downstream neural-signal utility.

By Jasmeet Singh Bindra, Siddharth Panwar, Shubhajit Roy Chowdhury
arXiv Machine Learning
Sep 14

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

BRIDGE-EEG is an efficient multi‑task EEG classification pipeline that leverages self‑supervised pretraining while dramatically reducing model size. It maps heterogeneous EEG recordings to a unified 62‑channel time‑frequency representation, pretrains an SE‑ResNet18 teacher with SimCLR, and distills it into smaller SE‑ResNet8 and SE‑ResNet4 students. The compact models achieve accuracy comparable to or better than larger foundation models on abnormality detection and emotion recognition, and they consume up to three times less energy on edge devices, enabling deployment on wearable hardware.

By Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
arXiv Machine Learning
Sep 2

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.

By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
arXiv Machine Learning
Aug 4

EEG-FM-Compass: Progress, Benchmarking, and Future Directions for EEG Foundation Models

arXiv:2601. 17883v3 Announce Type: replace Abstract: Electroencephalography (EEG) foundation models (FMs) have recently emerged as a promising paradigm for brain-computer interfaces, aiming to learn transferable neural representations from large-scale heterogeneous recordings.

By Dingkun Liu, Yuheng Chen, Zhu Chen, Zhenyao Cui, Yaozhi Wen, Jiayu An, Jingwei Luo, Dongrui Wu
arXiv Machine Learning
Oct 23

Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

The paper introduces MOPC, a memory‑augmented online test‑time adaptation framework for EEG motor‑imagery BCIs that operates without source data. It uses random‑mask perturbations to enforce prediction consistency, a confidence‑calibrated reweighting loss to handle pseudolabels and class imbalance, and a lightweight memory module to prevent catastrophic forgetting. Evaluated on BCI IV IIb and OpenBMI datasets, MOPC outperforms prior methods by 2.22% and 3.67% while maintaining per‑trial adaptation latency of 40–60 ms.

By Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou
arXiv AI
Oct 26

Controlled Evaluation of EEG Foundation Models: Random Initialisation, Band-Power and Validation-Selected Probes

The paper evaluates five publicly released EEG foundation models and an in‑house JEPA‑style model using a protocol that includes three key controls: an untrained encoder, spectral band‑power features, and a probe layer selected without test‑set look‑ahead. The study finds that selecting the probe layer by test score can modestly improve peak performance and alter the peak‑versus‑output relationship, that random initialization can match or surpass pretraining on certain tasks, and that full fine‑tuning rarely yields gains beyond seed variability. These findings lead the authors to propose four new reporting practices and to release all experimental results for re‑analysis.

By Mingyu Jeon, Suwan Cho, Jae Young Suh
arXiv Machine Learning
Jun 2

OmniEEG-Bench: A Standardized Evaluation Benchmark for EEG Foundation Models

arXiv:2606. 00815v1 Announce Type: new Abstract: Electroencephalography (EEG) supports a variety of brain-computer interface (BCI) tasks ranging from brain-state monitoring to human-LLM interactions.

By Ziling Lu, Zongsheng Li, Xinke Shen, Kexin Lou, Yingyue Xin, Xiaoqi Chen, Shinan Wang, Xiang Chen, Jiahao Fan, Chenyu Huang, Xin Xu, Zhoujie Hou, Chen Wei, Quanying Liu