arXiv:2608. 00943v1 Announce Type: cross Abstract: Automated sleep staging assigns discrete stage labels to successive time epochs throughout an overnight recording; conventionally each window spans at least 30 seconds, reflecting the minimum temporal resolution of the clinical scoring standard.
By Shuntian Zheng, Jiawei Wang, Cong Fu, Huan Yu, Chen Chen, Yu Guan, Sai Gu
The study compares six state‑of‑the‑art sleep‑staging foundation models on the MESA polysomnography dataset under three signal conditions: EEG only, ECG only, and EEG+ECG. Results show that EEG alone yields the highest accuracy (BIOT macro‑F1 = 0.7237), while switching to ECG alone incurs a consistent accuracy loss of about 0.35 macro‑F1 and reduces data rate to one‑third. Adding ECG to EEG offers little benefit for most models, indicating that EEG carries most of the sleep‑staging signal and that wearable‑compatible ECG alone is a viable but less accurate alternative.
By Hassan Mehdi, Riku Klen, Ayse Kosal Bulbul, Suzanne Timmons, Abdulhamit Subasi, Wei Chen, Zou Zhu, Muhammad Irfan
ECG‑SDI is a single‑lead electrocardiography framework that provides continuous sleep‑depth profiling and digital biomarker extraction. Trained on 12,392 overnight polysomnographic recordings, the two‑stage deep learning model achieved strong correlations with conventional sleep stages (0.828–0.848) and high REM classification AUROCs (0.954–0.977). The approach identified a disturbed sleep subtype linked to poorer subjective quality and higher mortality, and demonstrated measurable improvements in sleep‑depth metrics after CPAP therapy, suggesting its utility for home‑based sleep monitoring.
By Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang, Yuxi Zhou, Thomas Penzel, Shenda Hong
SleepFM-2 is a foundation model trained on 282,511 polysomnography recordings, covering over two million hours of multimodal sleep physiology. It outperforms its predecessor in disease prediction, sleep scoring, and event detection, and its representation improves performance across diverse tasks—including wearable sensing, subjective sleep reports, and transfer to other EEG modalities. When combined with age, sex, and BMI, the model meets stringent discrimination criteria for 215 EHR phenotypes, adding reproducible information beyond demographics for 155 of them.
By Rahul Thapa, Christopher Sun, William Theodor Lehn-Schioler, Sophia Claire Kivelson, Umaer Hanif, Hyatt Moore IV, Harrison G. Zhang, Hafsa Ahmed, Marcus Dige, Niels R. Lorenzen, Elisabeth Roxane M. Heremans, Adrien Specht, Ulysse Gimenez, Robin Guillard, Andreas Brink-Kjaer, James Zou, Emmanuel Mignot
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
arXiv:2606. 18506v1 Announce Type: new Abstract: Objective sleep assessment relies on polysomnography (PSG), yet clinical impact is often better reflected in patient-reported outcomes (PROs) such as sleepiness and fatigue.
By Saba A. Farahani, Elahe Khatibi, Manoj Vishwanath, Amir M. Rahmani, Hung Cao
arXiv:2512. 14461v2 Announce Type: replace Abstract: Sleep is essential for health, yet studying its dynamics requires manual sleep staging, a labor-intensive step in research and clinical care.
By Niklas Grieger, Jannik Raskob, Siamak Mehrkanoon, Stephan Bialonski
arXiv:2603. 26738v3 Announce Type: replace-cross Abstract: While automated sleep staging has achieved expert-level accuracy, its clinical adoption is hindered by a lack of auditable reasoning.
By Guifeng Deng, Pan Wang, Mengfan Niu, Jiquan Wang, Shuying Rao, Junyi Xie, Xi'ang Chen, Sha Zhao, Gang Pan, Wanjun Guo, Tao Li, Haiteng Jiang
arXiv:2508. 11664v2 Announce Type: replace-cross Abstract: Sleep stage classification is critical for diagnosing and managing disorders like sleep apnea and insomnia.
By Zahra Mohammadi, Parnian Fazel, Siamak Mohammadi
arXiv:2609.05550v1 Announce Type: cross
Abstract: Near-infrared (NIR) video is a promising modality for contactless sleep monitoring, but recent video-based sleep staging methods often use it as a ro...
By Kunmin Jang, You Rim Choi, Hun Heo, Heonjun Lee, Suahn Bae, Dongik Park, Hyun-Woo Shin, Hyung-Sin Kim
arXiv:2603. 00190v2 Announce Type: replace-cross Abstract: Polysomnography (PSG) provides the gold standard for sleep assessment but suffers from substantial heterogeneity across recording devices and cohorts.
By Zitao Shuai, Zongzhe Xu, David Yang, Wei Wang, Yuzhe Yang
arXiv:2607. 23284v1 Announce Type: new Abstract: Automated sleep staging is increasingly used in large-scale studies to derive sleep-architecture endpoints: total sleep time, REM latency, sleep efficiency, and bout-duration statistics.
By Juntang Wang, Yihan Wang, Hao Wu, Jiayu Gao, Shixin Xu, Dongmian Zou