arXiv:2606. 18506v1 Announce Type: new Abstract: Objective sleep assessment relies on polysomnography (PSG), yet clinical impact is often better reflected in patient-reported outcomes (PROs) such as sleepiness and fatigue.
By Saba A. Farahani, Elahe Khatibi, Manoj Vishwanath, Amir M. Rahmani, Hung Cao
ECG‑SDI is a single‑lead electrocardiography framework that provides continuous sleep‑depth profiling and digital biomarker extraction. Trained on 12,392 overnight polysomnographic recordings, the two‑stage deep learning model achieved strong correlations with conventional sleep stages (0.828–0.848) and high REM classification AUROCs (0.954–0.977). The approach identified a disturbed sleep subtype linked to poorer subjective quality and higher mortality, and demonstrated measurable improvements in sleep‑depth metrics after CPAP therapy, suggesting its utility for home‑based sleep monitoring.
By Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang, Yuxi Zhou, Thomas Penzel, Shenda Hong
arXiv:2609.36619v1 Announce Type: new
Abstract: Polysomnography (PSG) integrates multiple physiological signals to provide a comprehensive characterization of human sleep, yet its heterogeneous chann...
By Junyu Chen, Chenxi Liu, Shiqin Tang, Hao Miao, Wanyun Ling, Ziyue Li, Hongbin Liu, Gaofeng Meng
The study compares six state‑of‑the‑art sleep‑staging foundation models on the MESA polysomnography dataset under three signal conditions: EEG only, ECG only, and EEG+ECG. Results show that EEG alone yields the highest accuracy (BIOT macro‑F1 = 0.7237), while switching to ECG alone incurs a consistent accuracy loss of about 0.35 macro‑F1 and reduces data rate to one‑third. Adding ECG to EEG offers little benefit for most models, indicating that EEG carries most of the sleep‑staging signal and that wearable‑compatible ECG alone is a viable but less accurate alternative.
By Hassan Mehdi, Riku Klen, Ayse Kosal Bulbul, Suzanne Timmons, Abdulhamit Subasi, Wei Chen, Zou Zhu, Muhammad Irfan
arXiv:2607. 07720v2 Announce Type: replace-cross Abstract: Sleep physiology arises from the coordinated dynamics of the central nervous system (CNS) and autonomic nervous system (ANS), as reflected by multimodal polysomnography signals including EEG, EOG, EMG, ECG, and respiration.
By Zhoujie Hou, Song Wang, Kexin Lou, Mo Wang, Chen Wei, Quanying Liu
arXiv:2607. 07720v1 Announce Type: cross Abstract: Sleep physiology arises from the coordinated dynamics of the central nervous system (CNS) and autonomic nervous system (ANS), as reflected by multimodal polysomnography signals including EEG, EOG, EMG, ECG, and respiration.
By Zhoujie Hou, Song Wang, Kexin Lou, Mo Wang, Chen Wei, Quanying Liu
arXiv:2611.21643v1 Announce Type: new
Abstract: Estimating full-night electroencephalography (EEG) spectrograms from peripheral measurements could extend EEG-informed sleep analysis to recordings acq...
By Keondo Park, Arthur Delhaye, Younghoon Na, Hyun-Woo Shin, Hyung-Sin Kim
arXiv:2603. 00190v2 Announce Type: replace-cross Abstract: Polysomnography (PSG) provides the gold standard for sleep assessment but suffers from substantial heterogeneity across recording devices and cohorts.
By Zitao Shuai, Zongzhe Xu, David Yang, Wei Wang, Yuzhe Yang
arXiv:2602.15042v2 Announce Type: replace-cross
Abstract: Reliable sleep staging remains challenging for lightweight wearable devices such as single-channel electroencephalography (scEEG) or photople...
By Jiawei Wang, Liang Xu, Shuntian Zheng, Yu Guan, Kaichen Wang, Ziqing Zhang, Chen Chen, Laurence T. Yang, Sai Gu, M. Jamal Deen
MM‑Net is a multimodal, multi‑task neural network designed to simultaneously stage sleep and detect respiratory events in patients after ischemic stroke. It fuses sleep‑adapted EEG‑EOG embeddings with engineered neural descriptors and cardiorespiratory features using cross‑attention and shared temporal modeling, and employs cross‑fitting and ridge‑based embedding alignment to maintain representation consistency across patients. In a patient‑independent evaluation on the iSLEEPS dataset, MM‑Net achieved 76.3 % sleep‑stage accuracy (κ = 0.656) and a 0.825 AUC for respiratory‑event detection, outperforming baseline models; it also performed strongly on Sleep‑EDF and ISRUC‑I datasets and retained high respiratory AUCs when applied to unseen cohorts without retraining.
By Md Wahiduzzaman Suva, Esm E Moula Chowdhury Abha, Md Imtiaj Alam Sajin, Md Iftekharul Mobin, Jia Uddin
arXiv:2512. 14461v2 Announce Type: replace Abstract: Sleep is essential for health, yet studying its dynamics requires manual sleep staging, a labor-intensive step in research and clinical care.
By Niklas Grieger, Jannik Raskob, Siamak Mehrkanoon, Stephan Bialonski
The paper extends the SleepXAI framework to compare five explainable AI (XAI) methods for single‑channel EEG sleep staging. Using Spearman rank correlation with AASM‑defined EEG frequency bands as a clinical reference, the study finds that Integrated Gradients consistently yields the highest attribution fidelity across all sleep stages and apnea‑hypopnea severity groups. Experiments on the Sleep‑EDF and DREAMT datasets demonstrate strong classification performance and underscore the importance of choosing an appropriate attribution method for clinically interpretable sleep staging.
By Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar