arXiv:2602.15042v2 Announce Type: replace-cross
Abstract: Reliable sleep staging remains challenging for lightweight wearable devices such as single-channel electroencephalography (scEEG) or photople...
By Jiawei Wang, Liang Xu, Shuntian Zheng, Yu Guan, Kaichen Wang, Ziqing Zhang, Chen Chen, Laurence T. Yang, Sai Gu, M. Jamal Deen
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
arXiv:2512. 14461v2 Announce Type: replace Abstract: Sleep is essential for health, yet studying its dynamics requires manual sleep staging, a labor-intensive step in research and clinical care.
By Niklas Grieger, Jannik Raskob, Siamak Mehrkanoon, Stephan Bialonski
The study compares six state‑of‑the‑art sleep‑staging foundation models on the MESA polysomnography dataset under three signal conditions: EEG only, ECG only, and EEG+ECG. Results show that EEG alone yields the highest accuracy (BIOT macro‑F1 = 0.7237), while switching to ECG alone incurs a consistent accuracy loss of about 0.35 macro‑F1 and reduces data rate to one‑third. Adding ECG to EEG offers little benefit for most models, indicating that EEG carries most of the sleep‑staging signal and that wearable‑compatible ECG alone is a viable but less accurate alternative.
By Hassan Mehdi, Riku Klen, Ayse Kosal Bulbul, Suzanne Timmons, Abdulhamit Subasi, Wei Chen, Zou Zhu, Muhammad Irfan
arXiv:2607. 23284v1 Announce Type: new Abstract: Automated sleep staging is increasingly used in large-scale studies to derive sleep-architecture endpoints: total sleep time, REM latency, sleep efficiency, and bout-duration statistics.
By Juntang Wang, Yihan Wang, Hao Wu, Jiayu Gao, Shixin Xu, Dongmian Zou
arXiv:2611.21643v1 Announce Type: new
Abstract: Estimating full-night electroencephalography (EEG) spectrograms from peripheral measurements could extend EEG-informed sleep analysis to recordings acq...
By Keondo Park, Arthur Delhaye, Younghoon Na, Hyun-Woo Shin, Hyung-Sin Kim