arXiv:2603.26509v2 Announce Type: replace
Abstract: Computed tomography (CT) provides rich 3D anatomical detail but is often constrained by high radiation exposure, substantial costs, and limited ava...
By Martin Rath, Morteza Ghahremani, Yitong Li, Ashkan Taghipour, Marcus Makowski, Christian Wachinger
The paper introduces $K$-NeAS, a scalable neural architecture for multi-material CT reconstruction that replaces separate material networks with a shared latent backbone and a differentiable $K$-material soft selector. It automates attenuation bounds using a Gaussian Mixture Model and adds a scheduled auxiliary floater loss to reduce geometric hallucinations in sparse-view settings. Evaluated on four clinical CBCT datasets, $K$-NeAS achieves higher 3D volumetric fidelity—up to a 1.88 dB PSNR gain over a single-material baseline—and shows improved robustness under extreme sparsity, outperforming baselines by up to 1.17 dB.
By Daksh K. Shah, Emmanouil Nikolakakis, Razvan Marinescu
arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
The paper introduces LiftXR, a geometry‑guided framework that first reconstructs a 3D anatomical layout from bi‑planar X‑ray images and then uses this layout to guide CT volume reconstruction. An anatomical parser refines the layout by analyzing the reconstructed CT, enabling region‑specific intensity calibration. Experiments on two public datasets show LiftXR surpasses recent X‑ray‑to‑CT methods and improves downstream segmentation performance.
By Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu, Xinyu Liu, Yongsheng Pan, Yong Xia
The paper presents an anatomy‑aligned surface learning framework for reconstructing patient‑specific 4D myocardial surfaces from sparsely sampled short‑axis cine MRI. By parameterizing epicardial and endocardial surfaces on a shared circumferential‑longitudinal UV domain, the method transforms irregular 3D reconstruction into structured coordinate‑field completion, enabling explicit correspondence across subjects and cardiac phases. Experiments on three public datasets show the approach outperforms mesh‑based and implicit methods, achieving Chamfer distances around 2.6–2.9 mm and preserving ventricular function with small errors in volume and ejection fraction.
By Xiaohan Yuan, Xuan Yang, Qingya Li, Yangang Wang, Lei Li
arXiv:2609.15550v1 Announce Type: cross
Abstract: X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D pro...
By Deyu Meng, Mojtaba Lashgari, Yiying Wang, Abhirup Banerjee
arXiv:2609.22849v1 Announce Type: new
Abstract: In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural a...
By Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
GRIPNet is a new CT‑based pulmonary nodule detector that incorporates a Gaussian radial intensity prior, reflecting the regular pattern of intensity peaks at nodule centers and Gaussian decay outward. By replacing generic square convolutions with pinwheel, dual‑frequency, dilated masked attention, and an adaptive loss, the network aligns each module with measurable intensity properties. The method achieves state‑of‑the‑art mAP@0.5 scores of 95.3%, 91.6%, and 97.9% on KanserSet, LUNA16, and Lung‑PET‑CT‑Dx, respectively, while maintaining real‑time speed and improving high‑IoU localization.
By Haojie Yang, Ran Su
Patient-specific 4D myocardial reconstruction from cine MRI supports quantitative functional assessment, regional motion analysis, and simulation-based modeling. However, routinely acquired short-axis...
X-ray coronary angiography is the clinical gold standard for coronary artery disease during real-time cardiac interventions, but provides only 2D projections of inherently 3D vessels. Existing learnin...
arXiv:2608. 03430v1 Announce Type: cross Abstract: Four-dimensional cone beam CT (4D CBCT) is important for image-guided radiation therapy of thoracic cancers, but its use is limited by long scan times, causing high patient dose and motion/sparse-sampling artifacts.
By Ivo Herzig, Pascal Paysan, Daniel Barco, Marc Andr\'e Stadelmann, Frank-Peter Schilling, Igor Peterlik, Michal Walczak, Lijin Aryananda, Woo Sang Ahn, Rudolf Marcel F\"uchslin, Lukas Lichtensteiger