The study examined whether frozen bidirectional models could capture subject‑specific neuromuscular coupling between electromyographic activity and gait kinematics in able‑bodied and post‑stroke participants. Complete removal of the source modality increased reconstruction error, whereas cross‑participant substitution had minimal effect, indicating that models rely mainly on shared gait‑phase patterns rather than individualized signals. When predicting Performance‑Oriented Mobility Assessment scores, adding learned asymmetry metrics performed worse than a simple covariate baseline of walking speed, age, and sex.
By Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
arXiv:2605. 11314v3 Announce Type: replace-cross Abstract: Cerebral Palsy (CP) is a neurological disorder of movement and the most common cause of lifelong physical disability in childhood.
By Lauhitya Reddy, Seth Donahue, Jeremy Bauer, Susan Sienko, Anita Bagley, Joseph Krzak, Maura Eveld, Karen Kruger, Ross Chafetz, Vedant Kulkarni, Hyeokhyen Kwon
arXiv:2609.22619v1 Announce Type: new
Abstract: Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains co...
By Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
The paper evaluates six onboarding strategies for federated wearable models on five datasets using a leakage‑controlled protocol that fixes source checkpoints and separates calibration from evaluation. Results show that while average accuracy is high, person‑level performance can drop significantly, with some methods causing negative transfer for certain users. The study highlights that mean accuracy alone is insufficient and provides an auditable benchmark and failure map for future development.
By Rahil Aftab, Vineet Kumar Rakesh, Soumya Mazumdar, Tapas Samanta
Scoliosis5K is a multimodal gait dataset comprising 4,998 corridor-walking sequences from 3,010 participants, each paired with RGB video, binary silhouettes, and 2D poses. The proposed architecture fuses a pretrained RGB encoder with a silhouette transformer and regional kernel ridge scores, achieving 83.77% accuracy and 79.91% macro‑F1 on participant‑level scoliosis classification. Ablation studies show that the silhouette contributes modestly to overall accuracy but significantly improves recall for the positive scoliosis category.
By Zizhao Peng, Zihan Wang, Zheng Lv, Yan Wang, Ping Li, Fengwei An
arXiv:2605. 15862v2 Announce Type: replace Abstract: Understanding adaptive biomechanical systems requires distinguishing observable performance, static multivariate representation, longitudinal displacement, and internal approximation of observed change.
By Jacques Raynal, Pierre Slangen, Elsa Raynal, Jacques Margerit
arXiv:2607. 20237v1 Announce Type: new Abstract: Rehabilitation scoring systems are most useful when their outputs can be reviewed and interpreted within clinical workflows.
By Yankai Zheng, Yuhe Liu, Yuxin Ma, Tianci Xue, Jiayuan Tian, Yu Fu, Yuxuan Hu, Jianing Wang, Zichun Xiao, Junya Mu, Shaohui Ma
arXiv:2608. 15951v1 Announce Type: new Abstract: We study when a wearable stress system should surface a prediction rather than change it.
By Jaden Moon, Yu Wu, Arvind Pillai, Andrew Campbell
arXiv:2607. 01838v1 Announce Type: new Abstract: Counterfactual explanations (CEs) for multivariate time-series classifiers are often difficult to interpret in domains where experts reason in terms of semantic feature groups rather than individual channels.
By Emmanuel C. Chukwu, Rianne M. Schouten, Monique Tabak, Mykola Pechenizkiy
The paper introduces a wireless smart insole that uses 16 pressure sensors and a six‑axis IMU to detect sitting, standing, walking, and unstable walking. Data from 15 healthy adults were processed in overlapping windows and evaluated with participant‑independent cross‑validation, achieving macro‑F1 scores of 0.954–0.980 using Histogram‑Based Gradient Boosting. A compact 1D‑CNN performed similarly but did not significantly outperform the gradient‑boosting model.
By Edwin Rios, Antony Garcia, Fengpei Yuan, Xinming Huang
Counterfactual explanations (CEs) for multivariate time-series classifiers are often difficult to interpret in domains where experts reason in terms of semantic feature groups rather than individual channels. In rehabilitation movement analysis with multi-sensor inertial measurement units (IMUs), clinicians interpret motion through muscle-group and joint-segment abstractions; yet, most existing counterfactual methods operate at the channel level, producing scattered and biomechanically incoherent explanations.
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson