This scoping review examined 117 studies on video-based markerless motion capture, most published from 2024 onward and focused on healthy adults walking in laboratories. The studies identified five main pipeline architectures, but most reported only raw joint angles without biomechanical refinement, achieving sagittal lower‑limb agreement of about 5–6°, which falls short of clinical acceptability. Validation of out‑of‑plane kinematics, kinetics, and performance in older or pathological populations was rare, and emerging computer‑vision techniques such as foundation‑model mesh recovery and differentiable inverse kinematics were largely absent from validated work.
By Florian Delaplace (LAMHESS, CHU), Elodie Piche (LAMHESS), Fr\'ed\'eric Chorin (IUF, LAMHESS), Raphael Zory (IUF, LAMHESS)
arXiv:2610.19494v1 Announce Type: new
Abstract: Real-time monocular human pose estimation is an important sensing component for human-centered intelligent systems. While recent camera-based methods h...
By Liang Yu, Tao Zhu, Xiangqing Lu, Wenjian Luo, Liming Chen
arXiv:2610.05552v2 Announce Type: replace
Abstract: Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which f...
By Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland, Diego Paez-Granados
arXiv:2609.09670v1 Announce Type: new
Abstract: Monocular pose estimation enables low-cost gait analysis but is sensitive to missing keypoints caused by occlusion, detection errors, or efficiency-dri...
By Shubham Jariwala
arXiv:2605. 11314v3 Announce Type: replace-cross Abstract: Cerebral Palsy (CP) is a neurological disorder of movement and the most common cause of lifelong physical disability in childhood.
By Lauhitya Reddy, Seth Donahue, Jeremy Bauer, Susan Sienko, Anita Bagley, Joseph Krzak, Maura Eveld, Karen Kruger, Ross Chafetz, Vedant Kulkarni, Hyeokhyen Kwon
The paper introduces REHAB26-ViewAngles, a dataset of correct and incorrect rehabilitation exercise videos captured from many camera angles, and a new separability metric to evaluate pose‑estimation algorithms. It evaluates single‑camera 2D and 3D pose estimation and four multi‑camera approaches, showing that an optimally placed 2D camera can boost separability by 16.9% over a frontal view and that combining two views can improve accuracy by up to 13.1%. These findings provide concrete guidance for setting up camera systems in home and clinical rehabilitation monitoring.
By Miriama J\'ano\v{s}ov\'a, Andreas Lang, Petra Budikova, Jan Sedmidubsky
The study investigates how well a single consumer earbud IMU can estimate 3D body pose and whether adding foot IMUs improves accuracy. Using a multimodal capture pipeline with RGB‑D video, an AirPods head IMU, and Striv insole IMUs, the authors benchmark pose estimation across various motions and train recurrent models (IMUPoser and MobilePoser). Results show that a head IMU alone achieves 79.0 mm rigid‑MPJPE and 0.809 macro‑F1 for foot contact, while adding foot IMUs does not significantly improve pose and can even degrade performance due to insole orientation errors.
The paper identifies three shortcomings of the standard OKS‑mAP metric for 2D human pose estimation: it ignores visibility of keypoints, does not capture joint‑angle errors, and lacks a measure of temporal stability. To address these blind spots, the authors introduce a supplementary protocol with three modules—visibility‑stratified mAP, joint‑angle error metrics, and frame‑to‑frame jitter analysis—applied to four datasets and four models. Experiments show that aggregate mAP consistently overestimates performance on occluded scenes, that joint‑angle errors reveal differences hidden by mAP, and that temporal smoothing reduces jump rates without harming accuracy.
"whyItMatters":"The protocol provides a more nuanced evaluation of pose estimators, revealing hidden weaknesses in occlusion handling, angle precision, and temporal consistency that the standard OKS‑mAP metric masks."
By Yifan Fan
The paper introduces a cross‑modal distillation framework that combines the accuracy of inertial measurement unit (IMU) data with the practicality of video‑based gait analysis to detect freezing of gait (FOG) in Parkinson’s patients. By extracting invariant latent topologies from a pre‑trained kinematic oracle, the method supervises a visual architecture and fuses skeletal graph nodes with continuous spatial pixels to handle severe spatial occlusion during continuous 360° turns. Experiments on a public multimodal dataset show that this approach reduces tracking entropy and achieves precise FOG predictions without requiring wearable sensors.
By Chandan Biswas, Aryan Singh, Anabik Pal
arXiv:2606. 24960v1 Announce Type: new Abstract: Tailoring stroke rehabilitation requires assessing how movements are organized, not merely if they succeed.
By Tamim Ahmed, Thanassis Rikakis
The study examined whether frozen bidirectional models could capture subject‑specific neuromuscular coupling between electromyographic activity and gait kinematics in able‑bodied and post‑stroke participants. Complete removal of the source modality increased reconstruction error, whereas cross‑participant substitution had minimal effect, indicating that models rely mainly on shared gait‑phase patterns rather than individualized signals. When predicting Performance‑Oriented Mobility Assessment scores, adding learned asymmetry metrics performed worse than a simple covariate baseline of walking speed, age, and sex.
By Rafsan Jany, Md Rafid Islam, Mohammad Fahim Islam, Hafiz Abdur Rahman
Scoliosis5K is a multimodal gait dataset comprising 4,998 corridor-walking sequences from 3,010 participants, each paired with RGB video, binary silhouettes, and 2D poses. The proposed architecture fuses a pretrained RGB encoder with a silhouette transformer and regional kernel ridge scores, achieving 83.77% accuracy and 79.91% macro‑F1 on participant‑level scoliosis classification. Ablation studies show that the silhouette contributes modestly to overall accuracy but significantly improves recall for the positive scoliosis category.
By Zizhao Peng, Zihan Wang, Zheng Lv, Yan Wang, Ping Li, Fengwei An