arXiv:2610.05552v2 Announce Type: replace
Abstract: Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which f...
By Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland, Diego Paez-Granados
The study evaluated an adaptive gait biofeedback system for chronic ankle instability using a temporal convolutional classifier trained on angle-derived gait-cycle labels. In a leave-one-subject-out cross‑validation across 20 participants, the model achieved an AUROC of 0.948, with high sensitivity (0.941) but lower specificity (0.366). Seven participants in the adaptive group underwent nine sessions over three weeks, and post‑intervention, their frontal‑plane ankle angles were on average 5.168° lower than controls, though the retention effect was uncertain.
By Jaeyoon (Jason), Kim, Veronika Lebisova, Jeniya Sultana, Jaeyoung Cho, Jaeho Jang
This study introduces a transformer-based model that personalizes robot-mediated rehabilitation by mapping surface electromyography (sEMG) signals to contact force trajectories. Using a transformer encoder-decoder with rotary positional embeddings and flow matching, the model predicts trajectories with less than 8% error on unseen tasks and users, and can be fine-tuned within a single therapy session. Live tests show participants achieve target neuromotor activations with only 15% error, demonstrating the feasibility of activation-targeted trajectory prescription.
By Gabriel Parra, Kimia Khoshnami, Daniel S. Brown, Laura A. Hallock
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
The paper introduces a transformer-based model that personalizes robot-mediated rehabilitation by mapping surface electromyography (sEMG) muscle activations to contact force trajectories. Using a transformer encoder-decoder with rotary positional embeddings and flow matching, the model predicts trajectories with less than 8% error on unseen tasks and users, and can be fine-tuned within a therapy session. Live tests show participants achieve target neuromotor activations with only 15% error, demonstrating proof of concept for activation-targeted trajectory prescription.
arXiv:2609.22619v1 Announce Type: new
Abstract: Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains co...
By Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi