arXiv:2607. 01838v1 Announce Type: new Abstract: Counterfactual explanations (CEs) for multivariate time-series classifiers are often difficult to interpret in domains where experts reason in terms of semantic feature groups rather than individual channels.
By Emmanuel C. Chukwu, Rianne M. Schouten, Monique Tabak, Mykola Pechenizkiy
arXiv:2607. 20237v1 Announce Type: new Abstract: Rehabilitation scoring systems are most useful when their outputs can be reviewed and interpreted within clinical workflows.
By Yankai Zheng, Yuhe Liu, Yuxin Ma, Tianci Xue, Jiayuan Tian, Yu Fu, Yuxuan Hu, Jianing Wang, Zichun Xiao, Junya Mu, Shaohui Ma
arXiv:2608. 06122v1 Announce Type: cross Abstract: Inspired by recent evidence that transformer architectures benefit from Self-PreTraining (SPT) on long-context benchmarks, we investigate whether similar gains extend to multimodal, multivariate, and even simple univariate medical time series.
By Omar Coser, Antonio Orvieto, Paolo Soda, Loredana Zollo
arXiv:2601. 14590v3 Announce Type: replace Abstract: Counterfactual explanations (CFEs) provide human-centric interpretability by identifying the minimal, actionable changes required to alter a machine learning model's prediction.
By Shovito Barua Soumma, Asiful Arefeen, Stephanie M. Carpenter, Melanie Hingle, Hassan Ghasemzadeh
The paper introduces a transformer-based model that personalizes robot-mediated rehabilitation by mapping surface electromyography (sEMG) muscle activations to contact force trajectories. Using a transformer encoder-decoder with rotary positional embeddings and flow matching, the model predicts trajectories with less than 8% error on unseen tasks and users, and can be fine-tuned within a therapy session. Live tests show participants achieve target neuromotor activations with only 15% error, demonstrating proof of concept for activation-targeted trajectory prescription.
This study introduces a transformer-based model that personalizes robot-mediated rehabilitation by mapping surface electromyography (sEMG) signals to contact force trajectories. Using a transformer encoder-decoder with rotary positional embeddings and flow matching, the model predicts trajectories with less than 8% error on unseen tasks and users, and can be fine-tuned within a single therapy session. Live tests show participants achieve target neuromotor activations with only 15% error, demonstrating the feasibility of activation-targeted trajectory prescription.
By Gabriel Parra, Kimia Khoshnami, Daniel S. Brown, Laura A. Hallock