arXiv:2610.05552v2 Announce Type: replace
Abstract: Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which f...
By Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland, Diego Paez-Granados
The study evaluated an adaptive gait biofeedback system for chronic ankle instability using a temporal convolutional classifier trained on angle-derived gait-cycle labels. In a leave-one-subject-out cross‑validation across 20 participants, the model achieved an AUROC of 0.948, with high sensitivity (0.941) but lower specificity (0.366). Seven participants in the adaptive group underwent nine sessions over three weeks, and post‑intervention, their frontal‑plane ankle angles were on average 5.168° lower than controls, though the retention effect was uncertain.
By Jaeyoon (Jason), Kim, Veronika Lebisova, Jeniya Sultana, Jaeyoung Cho, Jaeho Jang
This study introduces a transformer-based model that personalizes robot-mediated rehabilitation by mapping surface electromyography (sEMG) signals to contact force trajectories. Using a transformer encoder-decoder with rotary positional embeddings and flow matching, the model predicts trajectories with less than 8% error on unseen tasks and users, and can be fine-tuned within a single therapy session. Live tests show participants achieve target neuromotor activations with only 15% error, demonstrating the feasibility of activation-targeted trajectory prescription.
By Gabriel Parra, Kimia Khoshnami, Daniel S. Brown, Laura A. Hallock
The study investigates whether Low‑Rank Adaptation (LoRA) can adapt three pretrained EEG foundation models—LaBraM‑base, REVE‑base, and REVE‑large—for binary left‑ vs. right‑hand motor imagery decoding in stroke patients. Using subject‑wise five‑fold cross‑validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 stroke dataset, LoRA significantly improved accuracy for LaBraM‑base (0.822) and REVE‑base (0.957) on the healthy cohort, but only REVE‑base LoRA achieved high performance (0.847±0.194) on stroke data, with a best mean accuracy of 0.952 in leave‑one‑subject‑out evaluation. The results demonstrate that healthy‑benchmark performance does not guarantee transfer to stroke EEG, highlighting the need for target‑domain adaptation and subject‑level assessment in rehabilitation BCIs.
By Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
The paper introduces a transformer-based model that personalizes robot-mediated rehabilitation by mapping surface electromyography (sEMG) muscle activations to contact force trajectories. Using a transformer encoder-decoder with rotary positional embeddings and flow matching, the model predicts trajectories with less than 8% error on unseen tasks and users, and can be fine-tuned within a therapy session. Live tests show participants achieve target neuromotor activations with only 15% error, demonstrating proof of concept for activation-targeted trajectory prescription.
arXiv:2609.22619v1 Announce Type: new
Abstract: Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains co...
By Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
arXiv:2606. 24960v1 Announce Type: new Abstract: Tailoring stroke rehabilitation requires assessing how movements are organized, not merely if they succeed.
By Tamim Ahmed, Thanassis Rikakis
arXiv:2605. 15862v2 Announce Type: replace Abstract: Understanding adaptive biomechanical systems requires distinguishing observable performance, static multivariate representation, longitudinal displacement, and internal approximation of observed change.
By Jacques Raynal, Pierre Slangen, Elsa Raynal, Jacques Margerit
The study presents a real‑time musculoskeletal surrogate for children with cerebral palsy, built from OpenSim parameters, joint kinematics, and muscle capacities. Using leave‑one‑subject‑out validation on nine pediatric gait recordings, the surrogate reproduces musculotendon lengths with high accuracy (R² ≈ 0.92–0.95, nRMSE < 8%) and achieves sub‑millisecond inference times, well below the 100 ms interactive‑rehabilitation target. A Monte Carlo credibility pilot reveals that small variations in anthropometry and muscle capacity lead to overconfident 90 % prediction intervals, highlighting the need for improved force modeling and uncertainty quantification.
By Mohammad Arif Ul Alam
arXiv:2610.07713v1 Announce Type: new
Abstract: Surface electromyography (sEMG) provides a wearable, noninvasive interface to neuromuscular activity for movement decoding and human-computer interacti...
By He Wang, Hongyuan Qi, Zhaoxian Zhang, Jinbin Luo, Linyi He, Mehul Motani, Changsheng Wu
arXiv:2609.22956v1 Announce Type: new
Abstract: Parkinson's disease alters gait and bilateral coordination, but machine-learning performance also depends on how continuous gait signals are represente...
By Md. Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid
The paper reports the winning solution to the MoCha 2026 Parkinsonian Gait Benchmark, achieving a macro‑F1 score of 0.6945 on unseen clinical sites. The approach relies on a frozen public motion encoder followed by a single 4×512 linear layer, and gains are largely attributed to three key steps: exact replication of the benchmark’s head recipe, averaging per‑walk posteriors at the subject level, and a label‑free transductive calibration of feature means and decision thresholds. Extensive ablation studies show that fine‑tuning the encoder or using alternative encoders does not improve performance, and the subject‑level aggregation is identified as the primary contributor to the top score.
By Junlong Shen