This scoping review examined 117 studies on video-based markerless motion capture, most published from 2024 onward and focused on healthy adults walking in laboratories. The studies identified five main pipeline architectures, but most reported only raw joint angles without biomechanical refinement, achieving sagittal lower‑limb agreement of about 5–6°, which falls short of clinical acceptability. Validation of out‑of‑plane kinematics, kinetics, and performance in older or pathological populations was rare, and emerging computer‑vision techniques such as foundation‑model mesh recovery and differentiable inverse kinematics were largely absent from validated work.
By Florian Delaplace (LAMHESS, CHU), Elodie Piche (LAMHESS), Fr\'ed\'eric Chorin (IUF, LAMHESS), Raphael Zory (IUF, LAMHESS)
arXiv:2609.22619v1 Announce Type: new
Abstract: Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains co...
By Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
arXiv:2610.05552v2 Announce Type: replace
Abstract: Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which f...
By Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland, Diego Paez-Granados
The study presents a real‑time musculoskeletal surrogate for children with cerebral palsy, built from OpenSim parameters, joint kinematics, and muscle capacities. Using leave‑one‑subject‑out validation on nine pediatric gait recordings, the surrogate reproduces musculotendon lengths with high accuracy (R² ≈ 0.92–0.95, nRMSE < 8%) and achieves sub‑millisecond inference times, well below the 100 ms interactive‑rehabilitation target. A Monte Carlo credibility pilot reveals that small variations in anthropometry and muscle capacity lead to overconfident 90 % prediction intervals, highlighting the need for improved force modeling and uncertainty quantification.
By Mohammad Arif Ul Alam
The Action Research Arm Test (ARAT) is a widely-used upper limb outcome measure in neurorehabilitation, but its ordinal scoring is subjective and suffers from limited sensitivity and specificity. We evaluated whether artificial-intelligence (AI)-based markerless motion capture (MMC), embedded into ARAT assessments during clinical routine, accurately reconstructs upper limb movement and yields valid, objective kinematic metrics carrying clinically meaningful information beyond the ordinal score.
The study evaluated an adaptive gait biofeedback system for chronic ankle instability using a temporal convolutional classifier trained on angle-derived gait-cycle labels. In a leave-one-subject-out cross‑validation across 20 participants, the model achieved an AUROC of 0.948, with high sensitivity (0.941) but lower specificity (0.366). Seven participants in the adaptive group underwent nine sessions over three weeks, and post‑intervention, their frontal‑plane ankle angles were on average 5.168° lower than controls, though the retention effect was uncertain.
By Jaeyoon (Jason), Kim, Veronika Lebisova, Jeniya Sultana, Jaeyoung Cho, Jaeho Jang