arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
arXiv:2610.35132v1 Announce Type: new
Abstract: Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible t...
By Yann Bourd\'e, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.
By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu
arXiv:2609.12860v1 Announce Type: new
Abstract: Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and tr...
By Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2508.17299v2 Announce Type: replace
Abstract: Low-dose computed tomography (CT) denoising is crucial for reduced radiation exposure while ensuring diagnostically acceptable image quality. Despi...
By Zhihao Chen, Qi Gao, Zilong Li, Junping Zhang, Yi Zhang, Jun Zhao, Hongming Shan
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
TransNSNet is a Transformer‑enhanced multi‑scale adversarial framework designed for CT‑to‑PET image synthesis. The study curated a paired CT‑PET dataset from a public NSCLC Radiogenomics collection and evaluated the framework against several baselines, reporting that TransNSNet achieved the best mean performance in nine of ten metrics while maintaining a smaller parameter footprint. Statistical analysis found no significant superiority over other models after correction, and the authors caution that synthesized PET‑like images should not replace clinically acquired PET scans.
By Shaojun Li, Xiaoyu Deng, Ikuo Keshi
The paper introduces a deep dictionary network (DDN) foundation model designed for ultra‑low‑dose CT (ULDCT) denoising across multiple organs. By cascading convolutional sparse coding layers with iterative soft‑thresholding, the architecture offers inherent interpretability, while dynamic dictionary and threshold modules enhance representation. The model is pre‑trained on over one million normal‑dose CT images and fine‑tuned on multi‑organ ULDCT datasets, achieving state‑of‑the‑art performance that consistently outperforms existing methods.
By Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu, Huazhu Fu