arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
EXACT is an explainable anomaly‑aware vision foundation model designed for 3D chest CT analysis. It learns spatially resolved representations from 25,692 paired CT scans and radiology reports, jointly performing organ segmentation and multi‑instance anomaly localization without voxel‑level annotations. In multinational, multi‑center studies, EXACT outperformed existing 3D medical foundation models across tasks such as multi‑disease diagnosis, zero‑shot anomaly localization, downstream adaptation, and visually grounded report generation.
By Xuguang Bai, Mingxuan Liu, Tongxi Song, Yifei Chen, Hongjia Yang, Kasidit Anmahapong, Zihan Li, Ying Zhou, Qiyuan Tian
arXiv:2606. 19460v1 Announce Type: cross Abstract: We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale.
By Fabio De Sousa Ribeiro, Emma A. M. Stanley, Charles Jones, Tian Xia, Dominic C. Marshall, Laurent Renard Trich\'e, Christopher V. Cosgriff, Panagiotis Dimitrakopoulos, Sotirios A. Tsaftaris, Ben Glocker
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
arXiv:2610.09253v1 Announce Type: new
Abstract: Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric info...
By Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
NV-Generate-BodyMask is a 3D latent diffusion model that generates whole-body CT segmentation masks with precise control over organ anatomy, tumor burden, and patient demographics. It operates in the compressed latent space of a frozen mask autoencoder, producing 256³ volumetric label maps conditioned on a 19‑dimensional vector via Adaptive Group Normalization and cross‑attention. Trained on 8,571 masks from 26 cohorts, the model achieves high Spearman correlations for organ size, excellent tumor recall for several lesion types, and strong demographic alignment.
By Can Zhao, Pengfei Guo, Dong Yang, Yufan He, Yucheng Tang, Ahmed Harouni, Benjamin Simon, Mason Belue, Stephanie Harmon, Baris Turkbey, Daguang Xu
Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free fram...
arXiv:2506.10633v2 Announce Type: replace
Abstract: Latent Diffusion Models have shown remarkable results in text-guided image synthesis in recent years. In the domain of natural (RGB) images, recent...
By Konstantinos Vilouras, Ilias Stogiannidis, Junyu Yan, Alison Q. O'Neil, Sotirios A. Tsaftaris
Generating CT volumes from MRI and CBCT can improve treatment planning in adaptive radiotherapy while avoiding additional radiation exposure. However, direct regression of CT intensities is challenged by the inherently high dynamic range and long-tailed distributions, thereby averaging out sparse yet clinically important structures.
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
DALE-CT introduces depth‑aware 2D slice encoders that learn an anatomical world model of chest CT scans without 3D or positional supervision. By sampling self‑supervised views across a physical $z$‑axis slab, the encoder captures how anatomy changes between neighboring slices, enabling it to recover slice ordering and distinguish slices by anatomy alone. The model, trained on a large 287k‑scan corpus, achieves state‑of‑the‑art performance on CT‑RATE and is released with full code and evaluation tools.
By Evan W. Damron, Mahmut S. Gokmen, Mitchell A. Klusty, Caroline N. Leach, Emily B. Collier, V. K. Cody Bumgardner