arXiv AI

CONFLUX: A Latent Diffusion Model for 3D Chest-CT Synthesis with RL Post-Training

arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.

arXiv AI
Jul 7

CONFLUX: A Latent Diusion Model for 3D Chest-CT Synthesis with RL Post-Training

arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.

By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv Computer Vision
Nov 5

EXACT: an explainable anomaly-aware vision foundation model for analysis of 3D chest CT

EXACT is an explainable anomaly‑aware vision foundation model designed for 3D chest CT analysis. It learns spatially resolved representations from 25,692 paired CT scans and radiology reports, jointly performing organ segmentation and multi‑instance anomaly localization without voxel‑level annotations. In multinational, multi‑center studies, EXACT outperformed existing 3D medical foundation models across tasks such as multi‑disease diagnosis, zero‑shot anomaly localization, downstream adaptation, and visually grounded report generation.

By Xuguang Bai, Mingxuan Liu, Tongxi Song, Yifei Chen, Hongjia Yang, Kasidit Anmahapong, Zihan Li, Ying Zhou, Qiyuan Tian
arXiv AI
Jun 19

Scaling Generative Foundation Models for Chest Radiography with Rectified Flow Transformers

arXiv:2606. 19460v1 Announce Type: cross Abstract: We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale.

By Fabio De Sousa Ribeiro, Emma A. M. Stanley, Charles Jones, Tian Xia, Dominic C. Marshall, Laurent Renard Trich\'e, Christopher V. Cosgriff, Panagiotis Dimitrakopoulos, Sotirios A. Tsaftaris, Ben Glocker
arXiv Computer Vision
Oct 22

NV-Generate-Body: 3D Latent Diffusion Model forControllable Anatomy, Tumor, and Demographic Body Mask Synthesis

NV-Generate-BodyMask is a 3D latent diffusion model that generates whole-body CT segmentation masks with precise control over organ anatomy, tumor burden, and patient demographics. It operates in the compressed latent space of a frozen mask autoencoder, producing 256³ volumetric label maps conditioned on a 19‑dimensional vector via Adaptive Group Normalization and cross‑attention. Trained on 8,571 masks from 26 cohorts, the model achieves high Spearman correlations for organ size, excellent tumor recall for several lesion types, and strong demographic alignment.

By Can Zhao, Pengfei Guo, Dong Yang, Yufan He, Yucheng Tang, Ahmed Harouni, Benjamin Simon, Mason Belue, Stephanie Harmon, Baris Turkbey, Daguang Xu
arXiv Computer Vision
5d ago

Image-Condition-Controlled Diffusion Network with Large-Scale CT Pretraining for CT-Free Attenuation Correction in Dynamic Cardiac PET

The paper introduces LUCID, a framework that uses a large-scale unpaired CT dataset to pretrain a diffusion model for generating attenuation maps (μ-maps) in dynamic cardiac PET scans. It combines a CNN that predicts an initial μ-map from non-attenuation-corrected PET frames with a CT-pretrained diffusion backbone that refines this prediction via a single denoising step conditioned on the PET frame through ControlNet. The method also proposes a voxel-wise temporal standard deviation metric to assess inter-frame variability without a reference map, and demonstrates superior quantitative accuracy on an in-house dataset of 102 patients compared to other approaches.

By Zhejia Zhang, Scott M. Leonard, Jinkui Hao, Ryan J. Avery, Richard L. Weinberg, Bo Zhou
Hugging Face Trending Papers
Jul 7

WING: A Window-Prior-Based Generative Network with Gated Inception for Cross-Modality CT Synthesis

Generating CT volumes from MRI and CBCT can improve treatment planning in adaptive radiotherapy while avoiding additional radiation exposure. However, direct regression of CT intensities is challenged by the inherently high dynamic range and long-tailed distributions, thereby averaging out sparse yet clinically important structures.

arXiv Computer Vision
Aug 31

Physics-Guided Flow Matching for CT Image Reconstruction

The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.

By Davide Evangelista