arXiv Computation and Language By Elif Dorukba\c{s}{\i}, \.Ilker T\"urker

Compact and Decodable Electrocardiogram Text for Large Language Models

Read the original on arXiv Computation and Language →

The paper introduces a deterministic encoding that compresses a twelve‑lead electrocardiogram into text suitable for large language models, balancing token count with information loss. Eight independent leads are encoded as amplitude letters and exact time gaps, while the remaining four limb leads are recovered algebraically. Applied to 21,388 PTB‑XL records, the method achieved an average token count of 2,866 (64.3% fewer than per‑sample transcription) with a decoded‑to‑reference signal correlation of 0.982 and negligible loss in diagnostic performance (AUC difference –0.0010).

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv Computation and Language.

arXiv Computer Vision
Nov 16

ECGGuard: Deep Watermarking of Electrocardiogram Signals With Error-Correcting

ECGGuard is a deep watermarking framework that embeds metadata into single‑lead ECG signals without quantizing the waveform. It uses a fully convolutional generator, a detector that decodes frame‑by‑frame, and a frozen arrhythmia classifier during training to prevent diagnostic changes. The system achieves over 98% bit accuracy under time shifts and recovers a 16‑bit payload exactly in 99.95% of clean segments, with robust performance under deletions, packet loss, and unseen subjects.

By Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
arXiv AI
Jul 7

ImputeECG: Deep Learning Reconstruction of Complete 12-Lead Electrocardiograms from Incomplete Recordings for Cardiac Assessment

arXiv:2607. 05009v1 Announce Type: cross Abstract: Complete digital 12-lead electrocardiograms (ECGs) are essential for AI-enabled cardiovascular assessment, yet many clinical ECG records, particularly those digitized from ECG images, remain incomplete because of short display formats, incomplete waveform digitization, lead loss, or signal corruption.

By Xiaocheng Fang, Haoyu Wang, Jieyi Cai, Qinghao Zhao, Jun Li, Shanwei Zhang, Guangkun Nie, Yujie Xiao, Shun Huang, Jiarui Jin, Hongmin Liu, Guodong Wang, Shuohua Chen, Liming Lin, Shouling Wu, Hongyan Li, Shenda Hong
arXiv AI
Sep 15

On the role of the tokenizer in ECG transformer models

The study investigates how different tokenization methods affect ECG Transformer models by comparing eight strategies across four backbone architectures on the CPSC2018 classification task. Physiology-aware tokenizations such as Median-beat and HeartLang achieve higher mean macro-AUCs (0.893 and 0.889) than point-wise and patch-wise approaches (0.822 and 0.824), while also reducing sequence length and training memory usage. Combining the two physiology-aware representations further improves macro-AUC by 8.2%.

By Jiawei Li, Fabio Bonassi, Johan Sundstr\"om, Thomas B. Sch\"on, Ant\^onio H. Ribeiro
arXiv Computation and Language
Sep 1

ECGQuest: Benchmarking and Fine-Tuning Language Models for Electrocardiography

ECGQuest is a new benchmark that evaluates language models on the contextual knowledge required for electrocardiogram interpretation, featuring 10,904 True/False questions derived from 23 ECG references and 2003‑2025 Computing in Cardiology proceedings. The study tested 23 commercial and open‑source models, finding that zero‑shot accuracy ranged from 49.5% to 74.4% and that fine‑tuning with Low‑Rank Adaptation improved all open‑source models by 6.5–14.1%, with the best fine‑tuned model achieving 76.3% accuracy and a five‑model ensemble reaching 78.5%. ECGQuest demonstrates that parameter‑efficient fine‑tuning can enable smaller models to compete with larger commercial ones on ECG‑specific tasks.

By Mohammadsina Hassannia, Matthew A. Reyna, Reza Sameni
arXiv AI
Nov 14

A Cardiorespiratory Foundation Model Pretrained on Ten Physiological Signals for Perioperative and Critical Care

The paper introduces CARMEN, a foundation model trained on ten cardiorespiratory waveforms without labels, covering 2.27 million modality-hours. It can process any subset of the signals from 10 s to 5 min and uses a conditioning mechanism called LSCNorm to restore absolute signal levels, improving performance on tasks such as intraoperative hypotension detection. Across 19 tasks from Korean and US cohorts, the frozen encoder outperformed supervised models on most tasks and surpassed other foundation models, maintaining robustness even when some channels are missing.

By Cheol-Hui Lee, Wookyung Kim, Hyeonhoon Lee, Garam Lee, Da-in Eun, Hyung-Chul Lee