arXiv:2603. 16551v2 Announce Type: replace-cross Abstract: Generative models are increasingly used to augment medical imaging datasets for fairer AI, yet a key assumption often goes unexamined: that generators produce equally high-quality images across demographic groups.
By Mahmoud Ibrahim, Bart Elen, Chang Sun, Gokhan Ertaylan, Michel Dumontier
The study benchmarks foundation models for chest X‑ray classification across a domain shift from adult to pediatric patients. Six foundation models and two CNN baselines were evaluated on a harmonized five‑label task using adult data for adaptation and tested on both adult and pediatric sets. Results show all models experience a substantial performance drop—over 10 percentage points—when applied to pediatric data, and deeper adaptation does not markedly improve cross‑population generalization.
By Sara In\'acio, Hugo Proen\c{c}a, Jo\~ao C. Neves
arXiv:2601.15891v4 Announce Type: replace
Abstract: Vision-language pretraining has driven progress in medical image representation learning, but it depends on paired image-text data and can inherit...
By Anas Anwarul Haq Khan, Mariam Husain, Pratik Jalan, Kshitij Jadhav
The study evaluated ten chest X‑ray AI classification models on 12 datasets from six countries, focusing on image‑level classification and measuring specificity at 95% sensitivity. MAVL and MedKLIP achieved the highest specificity (≈0.37) but still produced many false positives, with performance dropping on institutional cohorts compared to public benchmarks. No single model excelled across all findings, countries, or lesion types, highlighting limited generalisability.
By Qinmei Xu, Yiheng Li, Wenya Zhao, Zihao Zhao, Chuanjun Xu, Ahmet Gorkem Er, Xianghao Zhan, Brittany Dashevsky, Mohammed Alawad, Marc von der St\"uck, Marvin Gazibari\'c, Daniel Truhn, Shunsuke Shibata, Ryosuke Horino, Mio Ito, Akio Hiwatashi, Suyu Li, Mengya Yang, Ya Liu, Zhiyuan Sun, Changsheng Zhou, Haruka Itakura, Xiao Li, Olivier Gevaert
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
The paper introduces FRAME, a two‑step framework for auditing fairness claims in medical imaging. First, it derives a fair‑model reference distribution that captures the portion of subgroup performance differences attributable to sampling variation. Second, it tests the remaining difference using operators in representation space to assess whether demographic information or disease entanglement drives the bias. Across a large dataset of 702,206 images and 36 encoders, the reference explains a substantial median share of race and age differences, while interventions such as injecting demographic decodability or entangling disease direction have limited impact on the residual bias.
By Mahshad Lotfinia, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh