arXiv:2603. 16551v2 Announce Type: replace-cross Abstract: Generative models are increasingly used to augment medical imaging datasets for fairer AI, yet a key assumption often goes unexamined: that generators produce equally high-quality images across demographic groups.
By Mahmoud Ibrahim, Bart Elen, Chang Sun, Gokhan Ertaylan, Michel Dumontier
arXiv:2601.15891v4 Announce Type: replace
Abstract: Vision-language pretraining has driven progress in medical image representation learning, but it depends on paired image-text data and can inherit...
By Anas Anwarul Haq Khan, Mariam Husain, Pratik Jalan, Kshitij Jadhav
Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.
By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
The paper introduces FRAME, a two‑step framework for auditing fairness claims in medical imaging. First, it derives a fair‑model reference distribution that captures the portion of subgroup performance differences attributable to sampling variation. Second, it tests the remaining difference using operators in representation space to assess whether demographic information or disease entanglement drives the bias. Across a large dataset of 702,206 images and 36 encoders, the reference explains a substantial median share of race and age differences, while interventions such as injecting demographic decodability or entangling disease direction have limited impact on the residual bias.
By Mahshad Lotfinia, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh
arXiv:2607. 14984v1 Announce Type: new Abstract: Per-subgroup fairness audits of medical image classifiers face a sample-size problem: minority subgroups in held-out test sets have so few samples that the resulting confidence intervals on per-subgroup performance are wider than the bias the audit is meant to detect.
By Mahmoud Ibrahim, Bart Elen, Chang Sun, Gokhan Ertaylan, Michel Dumontier
arXiv:2607. 04478v1 Announce Type: cross Abstract: Automated chest X-ray classification remains challenging due to severe class imbalance, co-occurring pathologies, and the loss of localized features in conventional architectures.
By Moshiur Rahman, Shafqat Alam, Tasnia Binte Mamun