arXiv Machine Learning By Lilliane Linnet Musoke

GridForge: An Open Physics-Informed Digital Twin and Benchmark Suite for UK 11 kV Underground Distribution Cables

Read the original on arXiv Machine Learning →

GridForge is an open‑source, physics‑informed digital twin and benchmark suite designed for UK 11 kV underground distribution cables. It combines a verified thermal model, a calibrated synthetic dataset of 64 cables covering 320 cable‑years, a Physics‑Informed Neural Network surrogate with low RMSE, and a five‑task benchmark suite with baseline models. The project provides publicly available data, code, and models to enable independent verification and support maintenance planning and prioritisation for Distribution Network Operators.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv Machine Learning.

arXiv Machine Learning
Oct 5

Validated Data Onboarding for AI Demand Forecasting on U.S. Building Meter Data: Design, Controlled Evaluation, and a Corrected Negative Result

The paper introduces a data‑onboarding pipeline that detects and repairs defects in building meter data before training machine‑learning demand‑forecasting models. Controlled experiments on hourly electricity data from twelve U.S. buildings show that the pipeline restores forecast accuracy to clean‑data levels, even when defects affect up to 1.6% of training rows, and works across multiple models and horizons. The study also documents a first‑version over‑cleaning issue, its cause, and a per‑building calibration that corrects it, with all results reproducible from publicly pinned inputs.

By Yixuan Liang
arXiv Machine Learning
Sep 24

EvEMTBench: An Open Benchmark for Machine Learning in Power System Protection

EvEMTBench is an open, executable, and versioned benchmark designed to standardize the evaluation of machine‑learning methods for power system protection. It defines 12 protection and event‑analysis functions across four grids (20–345 kV) as 24 scored tasks, enabling structured assessment under varied observability, distribution shifts, and cross‑grid transfer scenarios. The benchmark includes committed data partitions, leakage controls, and reproducible reporting, and demonstrates that wider observability does not always help, that shifted conditions expose hidden failures, and that fault detection transfers better than fault localization.

By Julian Oelhaf, Georg Kordowich, Christian Bergler, Andreas Maier, Johann J\"ager, Siming Bayer