arXiv AI

vSV-ViT: Variable-size SuperVertex Vision Transformer for Cortical Surface Learning in Alzheimer's Disease

The paper introduces vSV-ViT, a Vision Transformer that processes variable-size supervertex (vSV) partitions of cortical surface meshes. vSVs group vertices into patches analogous to superpixels, avoiding issues like duplicated boundary vertices and inclusion of non-cortical regions. Experiments on Alzheimer’s disease brain image datasets show that vSV-ViT outperforms recent surface-based models in tasks such as AD and sex prediction, demonstrating its effectiveness for cortical surface learning.

arXiv AI
Sep 18

Bridging Modalities on the Cortex: Surface-based MRI to PET Translation with a Diffusion Bridge

The paper introduces DB‑SUiT, a surface‑based diffusion bridge that translates cortical MRI to PET images directly on the cortical manifold. It employs a conditional spherical U‑shaped vision Transformer to capture multi‑scale surface features and long‑range dependencies while incorporating demographic and subcortical information. Evaluations on two dementia datasets show that the synthesized PET surfaces outperform MRI and PET volumes in automated classification and achieve high diagnostic accuracy in a blinded reader study.

By Yitong Li, Alexandra Samoylova, Fabian Bongratz, Timo Grimmer, Dennis M. Hedderich, Igor Yakushev, Christian Wachinger
arXiv Computer Vision
Aug 31

3D MRI-Based Alzheimer's Disease Classification Using Multi-Modal 3D CNN with Leakage-Aware Subject-Level Evaluation

The paper presents a multimodal 3D convolutional neural network that classifies Alzheimer’s disease using raw OASIS 1 MRI volumes. It fuses structural T1 images with gray matter, white matter, and cerebrospinal fluid probability maps to capture complementary neuroanatomical information. Evaluated with 5‑fold subject‑level cross‑validation, the model achieves a mean accuracy of 72.34 % and an ROC AUC of 0.7781, with GradCAM visualizations highlighting anatomically relevant regions such as the medial temporal lobe and ventricles.

By Md Sifat, Sania Akter, Akif Islam, Md. Ekramul Hamid, Abu Saleh Musa Miah, Najmul Hassan, Md Abdur Rahim, Jungpil Shin
arXiv Computer Vision
Sep 28

Cross-Modality Structural Guidance in 3D Latent Diffusion for Robust FLAIR Super-Resolution

The paper introduces MR‑DiffuSR, a 3‑D latent diffusion framework that uses high‑resolution T1w structural priors to guide super‑resolution of thick‑slice FLAIR MRI scans. By applying cross‑modality structural swin attention and a mixed‑scale degradation strategy, the method avoids hallucinations and remains robust across varying slice thicknesses. On ADNI datasets, MR‑DiffuSR outperforms CNN and 2‑D diffusion baselines, achieving high PSNR, SSIM, and low LPIPS, and maintains strong white‑matter hyperintensity segmentation performance even at 7 mm equivalent slice thickness.

By Haoyu Lan, Jiazhen Zhang, John Onofrey, Bino Varghese, Nasim Sheikh-Bahaei, Arthur W. Toga, Jeiran Choupan
arXiv Machine Learning
Jun 16

Lesion-DDPM: Lesion-Enhanced 3D Diffusion for MS MRI Synthesis

arXiv:2606. 15457v1 Announce Type: cross Abstract: 3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns.

By Weidong Zhang, Yongchan Jung, Shafayat Mowla Anik, Furen Xiao, Vasudevan Janarthanan, Enkhzaya Chuluunbaatar, Byeong Kil Lee, Jeeho Ryoo
arXiv Machine Learning
Oct 21

Convergent Performance, Divergent Mechanisms in LoRA-Adapted Vision Foundation Models for Brain MRI

The study examines how LoRA adaptation of four Vision Foundation Models—DINOv3, SigLIP2, MerMED-FM, and BiomedCLIP—affects brain MRI tasks. Despite achieving similar segmentation accuracy (mean Dice 78‑81%), the models exhibit distinct internal dynamics, with early‑to‑mid layers being most crucial for segmentation. Restricting LoRA to these layers yields comparable performance while mitigating negative impacts on Alzheimer’s disease classification.

By Cecilia Diana-Albelda, Fiona Kekwick, Raghav Mehta, Aleksandra Kulbaka, Paul M. Matthews, Jesus Bescos, \'Alvaro Garc\'ia-Mart\'in, Wenjia Bai, Bernhard Kainz
arXiv Computer Vision
Nov 11

Comparative Evaluation of Deep Learning Models for Geographic Atrophy Segmentation in En Face OCT Images

The study compares five deep‑learning models—Nested U‑Net, ResU‑Net, nnUnet, Swin‑Unet, and MedSegDiff—plus a classical thresholding baseline for segmenting geographic atrophy (GA) in en‑face OCT images. Using a dataset of 269 OCT volumes from two devices (Cirrus and Spectralis) and a three‑step preprocessing pipeline, nnUnet achieved the highest Dice similarity coefficient (0.8882 ± 0.0033) on a held‑out validation set. The other models scored lower, with Dice values ranging from 0.6886 to 0.8453. Why it matters: The results show that nnUnet offers the most reliable performance for GA segmentation in en‑face OCT, providing a better balance of accuracy, stability, and efficiency under limited data conditions.

By Utkarsh Doshi, Adarsh Gadari, Sharat Chandra Vupparaboina, Joseph DeCicco, Giulia Gregori, Nicola Valsecchi, Nasiq Hasan, Elham Sadeghi, Jos\`e-Alain Sahel, Jay Chhablani, Kiran Kumar Vupparaboina, Sandeep Chandra Bollepalli