PPG-to-vital-sign reconstruction turns a wrist-worn photoplethysmogram into clinical waveforms such as the ECG. Long-horizon multivariate time-series forecasting underpins planning in energy, weather,...
PulseBound is a photoplethysmography (PPG) representation learner that enforces an explicit stored‑window information boundary, ensuring that encoder inputs depend only on a visible prefix and a content‑independent cutoff. By combining physiologically structured future‑beat prediction with prefix‑only normalization, suffix replacement, and aligned masking, PulseBound achieves stored‑suffix invariance, preventing changes in the stored suffix from affecting forecast context or predictions. Evaluated on MIMIC and VitalDB datasets, PulseBound reduces mean absolute error by over 22% compared to last‑visible‑beat persistence and outperforms seven other models on nine frozen linear‑probe and seven full‑fine‑tuning downstream tasks.
By Chenyang Xu, Donglin Xie, Xi Xiang, Xiaoyu Li, Yufan Lu, Jiqiun Gao, Yi Zhao, Xin-Yi Li, Guangpu Zhu, Zijian Wang, Xiwen Yang, Dezhen Wang, Lin Chen, Shenda Hong, Leilei Li
arXiv:2606. 15284v1 Announce Type: cross Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support.
By Chenyang He, Xinyi Shao, Shun Huang, Bosong Huang, Daoqiang Zhang, Ming Jing, Cheng Ding
PGP-Clinical-TimeKAN is a trajectory-first framework for joint probabilistic forecasting of multivariate physiological data, combining missingness-aware temporal encoders, a soft organ-system prior, patient-specific relations, nonlinear Kolmogorov‑Arnold messages, and a low‑rank multivariate Student‑t head. Evaluated on a MIMIC‑IV cohort of 6,882 patients, it achieves the second‑lowest normalized MAE and the lowest RMSE among 13 models, while providing calibrated probabilistic forecasts with empirical coverage at 50%, 80%, and 95% intervals. Ablation studies show that relational structure is critical for performance, and increasing covariance rank improves likelihood but not point accuracy.
whyItMatters":"The model demonstrates that joint trajectory forecasting can yield highly accurate, calibrated predictions of physiological trajectories, offering a potentially inspectable intermediate task for clinical deterioration prediction."
By Weizhi Nie, Rihao Chang, Weijie Wang, Yuting Su
arXiv:2607. 20027v1 Announce Type: new Abstract: Short-term Heart Rate Variability (HRV) forecasting could provide clinicians with actionable lead time for detecting autonomic dysfunction and adverse cardiac events.
By Luukas Per\"akyl\"a, Fahad Sohrab, Ville Hautam\"aki, Merja Hein\"aniemi, Sui Huang, Pekka Abrahamsson
arXiv:2608. 12592v1 Announce Type: new Abstract: Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient.
By Haochen Zhang, Jiaheng Guo, Yu-Chao Huang, Nicholas Knoz, Tianlong Chen
arXiv:2608. 12944v1 Announce Type: new Abstract: Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited.
By Hamza Shafiq, Hung Manh Pham, Bin Zhu, Pan Zhou, Jun Hu, Aaqib Saeed
Continuous physiological time series underpin modern clinical monitoring, yet many of the most informative signals are invasive, expensive, or simply unavailable for a given patient. Conditional generation offers a remedy: an absent signal can be synthesized from co-recorded signals and routine clinical variables.
arXiv:2610.33788v1 Announce Type: new
Abstract: Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. However, existing approaches to universal...
By Huaming Du, Zhixian Xie, Gaoyang Zhen, Gang Kou, Guisong Liu, Yanchao Tan, Wendan Tao, Yuhao Xu, Carl Yang
arXiv:2611.27206v1 Announce Type: cross
Abstract: Clinical monitoring and wearable devices capture complementary physiological signals, but their partially overlapping modality coverage makes within-...
By Linxiao Yang, Wenwei Wang, Tian Zhou, Bingqing Peng, Zihao Zhang, Zuyi Zhu, Jinjie Gu, Liang Sun
PPG-Bench is an open‑source benchmark that evaluates five publicly available photoplethysmography (PPG) foundation models across nine datasets and 26 tasks, covering cardiovascular state estimation, activity, sleep, screening, and identification. The benchmark tests models under four downstream regimes—linear probing, random forests, frozen MLP probes, and end‑to‑end finetuning—while also comparing them to three controls: a random/constant baseline, a deterministic pulse‑rate‑variability feature set, and a generic time‑series foundation model (MOMENT). Results show that over a third of task‑regime combinations yield no advantage for any PPG foundation model over the baseline, and in most cases no PPG‑specific model outperforms the simple controls, indicating that current PPG foundation models lack generalised, transferable representations.
By Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
The paper introduces a simple, model‑agnostic time‑domain augmentation called Sliding‑Window Reordering with Overlap Averaging. It transforms the joint input‑target sequence into overlapping windows, randomly reorders a fraction of them based on a variance criterion, and reconstructs the sequence by averaging overlaps to generate synthetic samples with controlled variation and minimal temporal distortion. Experiments show strong performance gains across nine long‑term forecasting benchmarks and four short‑term traffic benchmarks, with detailed ablations and diagnostics highlighting the effectiveness of each design choice.
By Jafar Bakhshaliyev, Johannes Burchert, Niels Landwehr, Lars Schmidt-Thieme