This study presents four deep‑learning pipelines—two‑dimensional and three‑dimensional—for segmenting age‑related macular degeneration (AMD) and diabetic macular edema (DME) lesions in optical coherence tomography (OCT) images. The models achieve Dice scores between 0.76 and 0.82 and demonstrate strong volumetric and surface calibration (r_vol, r_surf ≥ 0.97) on an in‑domain validation set. Generalization was assessed on the OLIVES clinical cohort using proxy metrics such as biomarker AUROC, central subfield thickness correlation, and longitudinal concordance, showing that the predictions still track clinical biomarkers outside the training distribution, albeit with reduced strength.
By Lucia Sundberg, Zhihao Zhao, M. Ali Nasseri
The study evaluates fundus-specific foundation models (FM) for detecting diabetic macular edema (DME) in retinal images. It compares two popular FM—RETFound and FLAIR—against a lightweight EfficientNet-B0 backbone across multiple datasets (IDRiD, MESSIDOR-2, and OCT-and-Eye-FundusImages). Results indicate that FM do not consistently outperform fine‑tuned CNNs; EfficientNet-B0 often matches or exceeds FM performance, with FLAIR being the most competitive FM.
By Franco Javier Arellano, Jos\'e Ignacio Orlando
Co-Annotator is a clinical AI system that distills expert gaze and dictation into two guidance components: a gaze‑aligned Vision Transformer that highlights fixation‑aligned areas of interest (AOIs) and an ontology‑bounded vision‑language model that pre‑fills editable biomarker summaries for retinal OCT. In controlled studies, each modality independently improved diagnostic accuracy and biomarker generation, and when combined across two academic institutions, the system increased correct diagnoses per minute by 40% and reduced comment editing time by 67% without compromising accuracy.
By Ziheng "Leo" Li, Benjamin Freeman, Akshay Raman, Kavin Aravindhan Rajkumar, Xinxin Fang, Rishabh Srivastava, Steven Feiner, Kaveri A. Thakoor
CF‑NODE is a counterfactual test‑time adaptation framework designed for diabetic retinopathy grading across different cameras, clinics, and patient populations. It ranks internal spatial nodes by attention, feature magnitude, and similarity, then progressively attenuates the highest‑ranked nodes and calibrates predictions based on the stability of the expected grade response. Evaluated on five external datasets, CF‑NODE outperforms four existing methods, achieving higher AUC and macro‑F1 scores and providing more balanced recognition across severity levels.
By Sabarish G, Deepak Parashar
arXiv:2608.24723v1 Announce Type: new
Abstract: Retinal fundus photography is widely used for screening and monitoring ocular diseases, but many modern classification pipelines rely on deep latent re...
By Xiaoyan Li, Shixin Xu, Arvind Gupta, Huaxiong Huang
The paper introduces a five‑stage, explainable pipeline for estimating the arteriolar‑to‑venular diameter ratio (AVR) from fundus images and for screening retinopathy. Each stage—vessel and artery‑vein masking, optic‑disc localization, vessel‑calibre estimation via a minimal‑chord boundary walk, and AVR calculation from dominant branches—produces inspectable intermediate outputs, and a threshold‑based rule yields the screening decision. In an exploratory cohort of 30 high‑resolution fundus images, the method achieved 96.7% accuracy, an F1‑score of 0.968, and an ROC‑AUC of 0.978, with ablation studies highlighting the impact of vessel pairing, calibre measurement, and aggregation.
By Sharan Sharmeela Karuppannan, Yoga Sri Varshan V, Subin Sahayam, Umarani Jayaraman