MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation
Read the original on arXiv Computer Vision →The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The Flow has not summarised this story yet — read it at arXiv Computer Vision.
The paper introduces ISLA, an ensemble learning framework for acute ischemic stroke lesion segmentation in diffusion MRI, built on nnU‑Net principles with attention modules, deep supervision, and varied input resolutions. A semi‑supervised variant, ISLA‑MT, incorporates unlabeled target‑domain images. Both models outperform state‑of‑the‑art pre‑trained models on internal validation and external multicenter cohorts, showing superior generalization, especially for low‑contrast lesions, and run in about five seconds per case.
arXiv:2608. 10291v1 Announce Type: cross Abstract: Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure.
arXiv:2609.00960v1 Announce Type: new Abstract: Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data acro...
arXiv:2606. 15457v1 Announce Type: cross Abstract: 3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns.
The paper introduces MR‑DiffuSR, a 3‑D latent diffusion framework that uses high‑resolution T1w structural priors to guide super‑resolution of thick‑slice FLAIR MRI scans. By applying cross‑modality structural swin attention and a mixed‑scale degradation strategy, the method avoids hallucinations and remains robust across varying slice thicknesses. On ADNI datasets, MR‑DiffuSR outperforms CNN and 2‑D diffusion baselines, achieving high PSNR, SSIM, and low LPIPS, and maintains strong white‑matter hyperintensity segmentation performance even at 7 mm equivalent slice thickness.
The paper introduces a 3D residual wavelet diffusion model for super‑resolving ultra low‑field MRI scans. By using a lossless wavelet reparameterisation, residual shifting, and domain randomisation, the method fits whole‑brain data on a single GPU, speeds up sampling, and generalises across scanners. It achieves volumetric accuracy comparable to leading regression approaches while producing per‑voxel uncertainty maps that reveal under‑determined regions and preserves disease‑relevant atrophy in cognitively impaired subjects.