This study benchmarks transformer models for Bangla medical named entity recognition (NER), comparing BanglaBERT, multilingual BERT (mBERT), XLM‑RoBERTa, and GPT‑4o mini under zero‑shot and few‑shot prompting. Across a full test set of 3,179 samples, fine‑tuned XLM‑RoBERTa achieves a new state‑of‑the‑art F1‑score of 0.5959, while BanglaBERT lags with 0.4937, suggesting that domain diversity outweighs language specificity. The analysis shows high performance on Medicine and Specialist entities (F1 > 0.83) but lower accuracy on Symptoms (F1 0.4367), and demonstrates that fine‑tuned transformers outperform prompt‑only approaches by a factor of 3.76.
By Rakib Abdullah, Md. Maruful Islam Maruf
arXiv:2511.00421v2 Announce Type: replace-cross
Abstract: Large language models (LLMs) show promise in medical applications, but their ability to detect and correct errors in clinical texts remains u...
By Naoto Iwase, Hiroki Okuyama, Junichiro Iwasawa
arXiv:2608.29890v1 Announce Type: new
Abstract: Biomedical Named Entity Recognition (NER) is fundamental to healthcare AI applications, including clinical decision support and medical information ext...
By Nhu Vo, Phuong Nguyen, Nu Uyen Phuong Le, Inigo Jauregi Unanue, Dung D. Le, Massimo Piccardi, Wray Buntine
arXiv:2605. 04221v2 Announce Type: replace-cross Abstract: Clinical named entity recognition from dental progress notes is challenging because documentation is highly unstructured, domain-specific, and often privacy-sensitive.
By Yao-Shun Chuang, Tushti Mody, Uday Pratap Singh, Shirindokht Shiraz, Chun-Teh Lee, Ryan Brandon, Muhammad F Walji, Xiaoqian Jiang, Bunmi Tokede
The paper presents a method for augmenting limited medical datasets using a fine‑tuned Microsoft Phi‑2 small language model (SLM). The SLM was adapted to the medical domain via supervised fine‑tuning on the MedQuad dataset, QLoRA, and few‑shot prompting, and then used to generate synthetic vital‑sign records. Experiments show that the fine‑tuned SLM outperforms the pretrained model on lexical and semantic metrics and that synthetic data augmentation improves an LSTM predictor’s accuracy from 89.0% to 93.7%, with gains in precision, recall, and F1‑score.
By Mihnea Sebastian Burlacu, Ionut Anghel, Tudor Cioara
CardioLM introduces a multilingual suite of small language models tailored for cardiology, comprising CardioBERTa encoders and CardioNER NER models trained on the CardioCCC corpus of 508 cardiology case reports translated into seven languages. The study shows that specialty‑specific pretraining reduces pseudo‑perplexity significantly but only marginally improves strict span‑level F1, whereas joint multilingual training with XLM‑RoBERTa‑large yields the best F1 scores across languages and entity types. Clinicians rated CardioNER far superior to rule‑based baselines, indicating practical value for multi‑country clinical information extraction.
By Manuela-Daniela Danu, Miguel Rodr\'iguez-Ortega, Alberto Becerra-Tome, Pablo Arancibia, Fernando Gallego-Donoso, Lorenzo Pratesi, Xi Bai, Andrei-Damian Dinescu, Salvador Lima-L\'opez, Andrea Guala, Saskia Haitjema, Jonas Mack, Michele Miranda, Wesam Al Nabki, Jan Rodr\'iguez-Miret, Vasile George Marica, Vladim\'ir Kincl, Kate\v{r}ina Dost\'alov\'a, Michael Andrej, Alicia Ujil, Corinne Allaart, Machteld Boonstra, Malin Overmars, Anoop Shah, Giovanna Ceroni, Jonathan Kossoff, Domenico D'Amario, Renzo Laborante, Antonio Iaconelli, Isabella Fumarulo, Jacopo Lenkowicz, Livia Lilli, Emma Weiss, Alex Scafa, Felix Lindberg, Milou Gamage, Eul\`alia Farr\'e-Maduell, S\'ebastien Brati\`eres, Martin Krallinger, Bram van Es
The study demonstrates that instruction‑tuning open‑weight large language models (LLMs) with over 500,000 public question‑answer pairs derived from ICD‑10‑GM, ICD‑O‑3, and OPS catalogues markedly improves ICD coding accuracy for German tumor diagnoses. After fine‑tuning, ICD‑10‑GM exact accuracy rose from 1.4–24 % to 41–58 %, and partial accuracy from 31–74 % to 73–83 %. The approach also eliminated malformed code outputs and achieved 99 % tumor‑diagnosis recognition, with performance scaling positively with model size but narrowing the gap between small and large models.
By Stefan Lenz, Lakisha Ortiz Rosario, Georg Vollmar, Arsenij Ustjanzew, Fatma Alickovic, Thomas Kindler, Torsten Panholzer
arXiv:2606. 01904v1 Announce Type: cross Abstract: The increasing application of Natural Language Processing (NLP) in healthcare demands language models specifically attuned to the complexities of clinical language.
By Christian Autenried, Cosimo Persia
This thesis explores how to select and adapt NLP models for global health literature when annotated data and computational resources are scarce. It compares skip‑gram word2vec models trained on increasingly large specialized corpora with BioWordVec for semantic tag discovery, finding that larger coverage does not always yield more useful domain associations. The study also evaluates convolutional spaCy models versus a RoBERTa transformer for named entity recognition, noting a trade‑off between higher F1 scores and longer inference time, and investigates MiniLM few‑shot versus BART‑MNLI zero‑shot classification for multi‑label topic classification, highlighting practical constraints of inference cost.
"whyItMatters":"The work provides empirical guidance on balancing model accuracy and resource demands for building knowledge systems in low‑resource global health settings."
By Genis Skura, Antoine Geissb\"uhler, Jean-Luc Falcone
arXiv:2610.03829v1 Announce Type: cross
Abstract: Real-world outpatient oncology notes contain specialised terminology, tumour staging expressions, treatment names, toxicity descriptions, and institu...
By Wuraola Oyewusi, Eliana Vasquez Osorio, Goran Nenadic, Gareth Price
The paper identifies a new problem in clinical natural language processing called the clinical lost‑in‑the‑middle (CLitM) effect, where large language models perform poorly on information located near the center of long electronic health record (EHR) documents. Using the MedAlign dataset, the authors quantify a 21.9‑percentage‑point accuracy gap across 2,196 instruction‑response pairs and six models, showing that most critical facts lie in the CLitM trough. They propose Query‑Conditioned Clinical Suppression (QCCS), a lightweight context‑selection gate that outperforms traditional retrieval methods (BM25, dense retrieval, cross‑encoder reranking) on a held‑out set of 83 instructions, achieving up to 25.3% accuracy for middle‑position queries.
whyItMatters":"The study demonstrates that standard retrieval strategies fail to reliably surface central clinical information, and that a query‑aligned selection mechanism can substantially improve model performance on critical EHR data."
By Sanjay Basu
arXiv:2609.36965v1 Announce Type: new
Abstract: System One models such as Jev offer an efficient alternative to generative language models for tasks that require decisions rather than open-ended resp...
By Zexiao Wang, Zihao Zhang, Xudong Wang, Pan Wang, Ziyi Ye, Haoyu Zhao, Zuxuan Wu, Shuicheng Yan