The paper introduces an unsupervised domain adaptation framework that aligns redundancy-reducing features to enable accurate 3D segmentation of cone-beam CT (CBCT) without target-domain annotations or inference-time adaptation. The method is architecture-agnostic, working with both CNN-based and ViT-based foundation models, and is evaluated on two liver segmentation benchmarks for interventional vascular procedures and radiation therapy. Results show that even large pretrained segmentation networks need explicit feature-space bridging to generalize across diagnostic CT and CBCT, and the proposed approach consistently outperforms existing pretrained foundation models and UDA strategies.
By Gauthier Miralles, Loic Le Folgoc, Vincent Jugnon, Pietro Gori
arXiv:2607. 02998v1 Announce Type: cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2607. 02998v2 Announce Type: replace-cross Abstract: Controllable generative models of 3D medical images can synthesize volumes with specified clinical attributes, but this demands samples that are simultaneously high-fidelity, natively 3D, and faithful to the requested conditioning.
By Max Van Puyvelde, Halil Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2606. 13341v1 Announce Type: cross Abstract: We present a Dual-Domain Equivariant Generative Adversarial Network (DDE-GAN) for multimodal CT-PET image synthesis.
By Gabriel Steele, Alzahra Altalib, Alessandro Perelli
arXiv:2608. 08135v1 Announce Type: cross Abstract: Cross-modality medical image translation can reduce the burden of multi-modal acquisitions, yet the field remains constrained by two coupled limitations: methods operate on 2D slices or 3D patches rather than whole volumes, and train a separate model for each translation task.
By Daniele Molino, Alessio Zoboli, Camillo Maria Caruso, Valerio Guarrasi, Paolo Soda
arXiv:2607. 11941v1 Announce Type: cross Abstract: Computed tomography (CT) is a critical imaging modality for clinical diagnosis, but reducing radiation dose inevitably introduces severe noise and structured artifacts that degrade image quality.
By Md Imam Ahasan, Guangchao Yang, A F M Abdun Noor, Kah Ong Michael Goh, S. M. Hasan Mahmud, Md Mahfuzur Rahman
arXiv:2609.08627v1 Announce Type: cross
Abstract: In proton therapy, plans are typically optimized on a single planning CT, making robustness evaluation essential under anatomical changes. However, c...
By Tomas Guija-Valiente, Blanca Rodriguez-Gonzalez, Norberto Malpica
arXiv:2608. 09992v1 Announce Type: cross Abstract: Controllable generation guided by external knowledge is a key requirement in modern generative deep learning applications, enabling the synthesis of samples with explicit constraints on semantic content, structural properties, and variability.
By Francesca Pia Panaccione, Eugenio Lomurno, Matteo Matteucci
The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.
By Davide Evangelista
arXiv:2606. 19460v1 Announce Type: cross Abstract: We introduce the first generative foundation model for chest radiograph synthesis trained from scratch at the billion-parameter scale.
By Fabio De Sousa Ribeiro, Emma A. M. Stanley, Charles Jones, Tian Xia, Dominic C. Marshall, Laurent Renard Trich\'e, Christopher V. Cosgriff, Panagiotis Dimitrakopoulos, Sotirios A. Tsaftaris, Ben Glocker
arXiv:2602. 05387v2 Announce Type: replace-cross Abstract: MRI provides superior soft tissue contrast without ionizing radiation; however, the absence of electron density information limits its direct use for dose calculation.
By Zolnamar Dorjsembe, Hung-Yi Chen, Furen Xiao, Hsing-Kuo Pao
arXiv:2606. 16212v1 Announce Type: cross Abstract: Sparse-view CT reduces radiation dose and scanning time by acquiring fewer projection views, but angular undersampling makes reconstruction severely ill-posed, causing streak artifacts, structural blurring, and loss of fine details.
By Jigang Duan, Jiayi Wang, Heran Wang, Ping Yang, Genwei Ma, Xing Zhao