arXiv:2610.07071v1 Announce Type: new
Abstract: The quality of computed tomography (CT) images is significantly affected by the selection of reconstruction kernels: sharp kernels improve spatial reso...
By Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
The paper introduces a deep dictionary network (DDN) foundation model designed for ultra‑low‑dose CT (ULDCT) denoising across multiple organs. By cascading convolutional sparse coding layers with iterative soft‑thresholding, the architecture offers inherent interpretability, while dynamic dictionary and threshold modules enhance representation. The model is pre‑trained on over one million normal‑dose CT images and fine‑tuned on multi‑organ ULDCT datasets, achieving state‑of‑the‑art performance that consistently outperforms existing methods.
By Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu, Huazhu Fu
The paper introduces Multilevel Stochastic Plug-and-Play (ML‑SPnP), a wavelet‑based multilevel stochastic PnP algorithm for sparse‑view CT reconstruction. It uses a coarse‑to‑fine initialization followed by a finite sequence of resolution‑specific denoiser corrections, and inherits convergence guarantees from the underlying stochastic PnP method. Experiments on two CT datasets with 20–50 projection views show that ML‑SPnP achieves comparable reconstruction quality to existing stochastic PnP methods while generally requiring less reconstruction time.
By Antoine De Paepe, Alexandre Bousse, Dimitris Visvikis
Noise2Match is a self‑supervised method for low‑dose CT denoising that uses an adaptive inter‑slice matching network to model and correct the label transition between adjacent slices. By ensuring the equal‑mean condition of the Noise2Noise framework, it theoretically matches supervised training with paired noisy‑clean data. The approach also extends effectively to low‑dose cone‑beam CT, outperforming existing image‑domain self‑supervised methods.
The paper presents an unsupervised autoencoder that uses a Cohen-Daubechies-Feauveau (CDF 97) wavelet transform in its latent space to denoise neutron imaging data from inertial confinement fusion experiments. The method targets mixed Gaussian‑Poisson noise, preserving fine details and edges that are crucial for image reconstruction. Benchmarks on simulated and experimental NIF datasets show lower reconstruction error and better edge preservation than conventional filtering techniques such as BM3D.
By Asya Y. Akkus, Bradley T. Wolfe, Pinghan Chu, Chengkun Huang, Chris S. Campbell, Mariana Alvarado Alvarez, Petr Volegov, David Fittinghoff, Robert Reinovsky, Zhehui Wang
arXiv:2610.32203v1 Announce Type: new
Abstract: Gradient-based learning of morphological operators is hindered by locally sparse derivatives with respect to the structuring elements. We develop a met...
By Diego Marcondes, Wonder A. L. Alves, Ronaldo F. Hashimoto
arXiv:2608.29820v1 Announce Type: new
Abstract: Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservatio...
By Juneyong Lee, Jaeyoung Choi
arXiv:2610.35132v1 Announce Type: new
Abstract: Positron Emission Tomography (PET) provides important metabolic information for tumor detection and staging but remains significantly less accessible t...
By Yann Bourd\'e, Lea Bogensperger, Arnela Hadzic, Michael Krauthammer
arXiv:2606. 26712v1 Announce Type: cross Abstract: Skin lesion segmentation is a key task in computer-aided dermatological diagnosis, where accuracy directly impacts downstream analysis and disease classification.
By Jingjun Gu, Chaojie Shen, Yifeng Cao, Wei Zhang, Yiliu Li, Aobo Fan
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv:2608. 08919v1 Announce Type: cross Abstract: During standard radiotherapy planning, repeated CT acquisitions are often required for patient registration, verification, and adaptive planning, resulting in increased cumulative X-ray dose.
By Alzahra Altalib, Chunhui Li, Christopher Hamill Taylor, Sankar Pillai, Alessandro Perelli