arXiv:2610.07067v1 Announce Type: new
Abstract: Image denoising is a crucial task in image processing, focused on improving image quality by minimizing noise while maintaining essential structural el...
By Mahmoud Nasr, Jan K. Argasinski, Krzysztof Brzostowski, Adam Piorkowski
arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.
By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
arXiv:2509. 21913v2 Announce Type: replace-cross Abstract: Background: Cone-beam computed tomography CBCT is a commonly used modality for image guided radiotherapy.
By Alzahra Altalib, Chunhui Li, Alessandro Perelli
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv:2610.19466v1 Announce Type: new
Abstract: Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic find...
By Yifei Sun, Fenglei Fan, Junhao Jia, Wenming Deng, Hongxia Xu, Changmiao Wang, Ruiquan Ge
Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic findings, increasing the risk of diagnostic uncertain...
arXiv:2610.19120v1 Announce Type: cross
Abstract: Purpose: Free-breathing abdominal MRI is limited by respiratory motion, which introduces image artifacts and k-space inconsistencies. Existing recons...
By Majd Helo (Medical Image and Data Analysis, Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany), Dominik Nickel (Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany), Thomas Kuestner (Medical Image and Data Analysis)
arXiv:2608.29820v1 Announce Type: new
Abstract: Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservatio...
By Juneyong Lee, Jaeyoung Choi
The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.
By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu
Noise2Match is a self‑supervised method for low‑dose CT denoising that uses an adaptive inter‑slice matching network to model and correct the label transition between adjacent slices. By ensuring the equal‑mean condition of the Noise2Noise framework, it theoretically matches supervised training with paired noisy‑clean data. The approach also extends effectively to low‑dose cone‑beam CT, outperforming existing image‑domain self‑supervised methods.
The study introduces a voxel-spacing-aware radiomic framework that incorporates physical geometry into texture computation without resampling, modifying PyRadiomics to preserve native image signals. Four extraction configurations—native non-resampled (NR), isotropic resampling (RS), voxel-spacing-aware (VS), and fake-isotropic preprocessing (FK)—were compared across 685 CT pulmonary nodules and 209 MRI breast cases, evaluating 196 radiomic descriptors. Results show that VS closely matches NR (median ICC(A,1) ≈0.998) while RS and FK exhibit lower agreement, indicating that spacing metadata alone can significantly influence radiomic features.
By David Corral Fontecha, Juan Miranda Bautista, Pablo Menendez Fern\'andez-Miranda, Sergio Rubio-Mart\'in, Lara Lloret Iglesias, Jose A. Vega
Objective: Radiomic texture features are usually computed in voxel-index neighborhoods, implicitly assuming isotropic spatial relationships. In anisotropic images, this can confound voxel geometry with interpolation-induced signal changes.