arXiv:2406. 13128v2 Announce Type: replace-cross Abstract: Due to the intricate structure of vascular trees, minor segmentation errors can significantly alter connectivity patterns and increase variability in extracted morphological properties.
By Jo\~ao Pedro Parella, Matheus Viana da Silva, Cesar Henrique Comin
arXiv:2609.01598v1 Announce Type: new
Abstract: Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branch...
By Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
arXiv:2608. 19769v1 Announce Type: cross Abstract: Fast and accurate segmentation of Acute Ischemic Stroke (AIS) lesions is essential for stroke prognosis and treatment planning.
By Maunil Shah, Vaanathi Sundaresan
arXiv:2610.01542v1 Announce Type: new
Abstract: Cerebral microbleeds (CMBs) and cortical superficial siderosis (cSS) are imaging markers of cerebral small vessel disease, but their automated segmenta...
By Yuan Cao, Sumeet Dash, Antonia Zachariadis, Stefanie Schreiber, Katja Neumann, Jose Bernal
arXiv:2608.24783v1 Announce Type: new
Abstract: Accurate segmentation of coronary arteries in X-ray angiography videos is essential for quantitative coronary analysis and image-guided interventions....
By Lin Xi, Yingliang Ma
arXiv:2608.30404v1 Announce Type: cross
Abstract: Accurate segmentation of the coronary vessel lumen is a prerequisite for quantitative assessment of atherosclerotic plaque and perivascular adipose t...
By Kit M. Bransby, Esther {\O}ksnebjerg, Kristoffer Kj{\ae}r, Jacob Kirkeby, Yasmin El Youssef, A\"ida Jim\'enez, Philip R. Pedersson, Martina C. de Knegt, Klaus F. Kofoed, Rasmus R. Paulsen
arXiv:2607. 05317v2 Announce Type: replace-cross Abstract: Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates.
By Akshay Gokhale, Mansi Dhamne
arXiv:2607. 05317v1 Announce Type: cross Abstract: Automated detection of intracranial aneurysms (IAs) from CT angiography (CTA) is severely hindered by high false-positive rates.
By Akshay Gokhale (Sardar Patel Institute of Technology, Mumbai), Mansi Dhamne (Sardar Patel Institute of Technology, Mumbai)
arXiv:2608. 19965v1 Announce Type: cross Abstract: Segmentation of curvilinear anatomical structures in 3D medical images remains challenging due to complex topology, severe class imbalance, weak contrast, and large variations in structure morphology.
By Sidi Mohamed Sid'El Moctar, Nicolas Vitry, H\'el\`ene Bouvrais
X‑LMC is a spatiotemporal deep‑learning framework that automatically scores leptomeningeal collateral (LMC) status from time‑resolved biplane digital subtraction angiography (DSA). It uses a DINOv2 backbone to encode spatial frames, a token‑level cross‑view attention module to fuse orthogonal projections, and a recurrent network to model contrast bolus dynamics. On a multicenter dataset of 134 M1‑segment occlusion patients, X‑LMC achieved a Quadratic Weighted Kappa of 0.398 and a macro‑F1 of 0.711, outperforming static and other spatiotemporal baselines and matching clinical inter‑rater agreement.
CMRVision is a cardiac magnetic resonance (CMR) foundation model trained with DINOv3-style self‑supervised learning on 36 million multi‑center, multi‑sequence CMR images. It outperforms prior natural‑image, medical‑image, supervised, and CMR baselines on multi‑task segmentation (cine, LGE, mapping) and cine view classification, achieving Dice scores of 0.940–0.967 for LV and 0.855–0.905 for myocardium, and a zero‑shot Dice of 0.692 on unseen LGE long‑axis views. The model demonstrates robust cross‑view generalization and highest average accuracy (0.906) for cine view classification.
By Athira J. Jacob, Puneet Sharma, Daniel Rueckert
arXiv:2606. 14828v1 Announce Type: cross Abstract: Leptomeningeal collaterals (LMCs) are an important prognostic factor in acute ischemic stroke.
By Junyong Cao, Hakim Baazaoui, Chinmay Prabhakar, Suprosanna Shit, Lukas Bastian Otto, Susanne Wegener, Bjoern Menze, Ezequiel de la Rosa