arXiv Computer Vision By Mohammad Arif Ul Alam

Real-Time Musculoskeletal Surrogates for Pediatric Cerebral Palsy: a Credibility Pilot

Read the original on arXiv Computer Vision →

The study presents a real‑time musculoskeletal surrogate for children with cerebral palsy, built from OpenSim parameters, joint kinematics, and muscle capacities. Using leave‑one‑subject‑out validation on nine pediatric gait recordings, the surrogate reproduces musculotendon lengths with high accuracy (R² ≈ 0.92–0.95, nRMSE < 8%) and achieves sub‑millisecond inference times, well below the 100 ms interactive‑rehabilitation target. A Monte Carlo credibility pilot reveals that small variations in anthropometry and muscle capacity lead to overconfident 90 % prediction intervals, highlighting the need for improved force modeling and uncertainty quantification.

Machine-generated by The Flow from the publisher's headline and feed description — not written or checked by a human. The full article lives at arXiv Computer Vision.

arXiv AI
Jun 9

Quantifying Rodda and Graham Gait Classification from 3D Markerless Kinematics derived from a Single-view Video in a Heterogeneous Pediatric Clinical Cohort

arXiv:2605. 11314v3 Announce Type: replace-cross Abstract: Cerebral Palsy (CP) is a neurological disorder of movement and the most common cause of lifelong physical disability in childhood.

By Lauhitya Reddy, Seth Donahue, Jeremy Bauer, Susan Sienko, Anita Bagley, Joseph Krzak, Maura Eveld, Karen Kruger, Ross Chafetz, Vedant Kulkarni, Hyeokhyen Kwon
arXiv AI
6d ago

Uncertainty-Aware Federated Learning for Infant Movement Analysis

The paper introduces the first federated learning framework for infant movement analysis, specifically targeting General Movement Assessment using skeletal motion data. It employs Monte Carlo Dropout to estimate predictive uncertainty and proposes an Uncertainty-Aware Federated Averaging (UA‑FedAvg) strategy that weights client updates by this uncertainty. Experiments with three clients show that federated learning outperforms local models and approaches centralized training performance, with UA‑FedAvg generally surpassing standard FedAvg.

By Edmond S. L. Ho
arXiv Machine Learning
Sep 21

Beyond Kinematics: Benchmarking Simulation Fidelity for Muscle-Driven Imitation Learning

The paper compares two leading motion‑imitation reinforcement learning pipelines—HyFyDy, which uses detailed musculotendon modeling, and MuJoCo, which focuses on computational speed. Using the same human motion‑capture and EMG data, both pipelines reproduce kinematics similarly, but HyFyDy’s muscle activation predictions align more closely with experimental EMG (RMSE 0.164, r = 0.4) than MuJoCo’s (RMSE 0.344, r = 0.11). The authors conclude that HyFyDy’s higher physiological realism makes it currently more suitable for musculoskeletal modeling, though both systems need further development for GPU‑parallelizable environments and robotic assistive‑device design.

By Ayah G. Ahmad, Claire E. Borden, Maegan Tucker
arXiv Computer Vision
Sep 3

Cross-Model Distillation of a Human-Pose Foundation Model from Unannotated Infant Video for Markerless 3D Pose Estimation

The paper presents a method for improving markerless 3D pose estimation in infants by cross‑model distillation. Using unannotated infant video, a frozen Sapiens 2 pose model provides dense pseudo‑labels that guide fine‑tuning of the SAM 3D Body model. On a held‑out dataset of eleven infants, the fine‑tuned model shows significant gains in 2D keypoint accuracy and 3D joint error compared to the original SAM 3D Body model.

By R. James Cotton, Divya Joshi, Colleen Peyton
Hugging Face Trending Papers
Jul 26

Markerless Motion Capture in Routine Clinical Upper Limb Assessments: Validity and Insights Beyond Ordinal Scoring

The Action Research Arm Test (ARAT) is a widely-used upper limb outcome measure in neurorehabilitation, but its ordinal scoring is subjective and suffers from limited sensitivity and specificity. We evaluated whether artificial-intelligence (AI)-based markerless motion capture (MMC), embedded into ARAT assessments during clinical routine, accurately reconstructs upper limb movement and yields valid, objective kinematic metrics carrying clinically meaningful information beyond the ordinal score.