arXiv:2607. 08408v1 Announce Type: cross Abstract: Gaussian splatting is the current state-of-the-art for dense, deformable 3D anatomy reconstruction in robot-assisted minimally invasive surgery (RAMIS); however, most pipelines are offline and depend on accurate camera trajectory priors (often from robotic kinematics), limiting applicability when priors are missing or noisy.
By Tianyi Song, Sierra Bonilla, Xinwei Ju, Evangelos Mazomenos, Danail Stoyanov, Adam Schmidt, Omid Mohareri, Sophia Bano, Francisco Vasconcelos
Gaussian splatting is the current state-of-the-art for dense, deformable 3D anatomy reconstruction in robot-assisted minimally invasive surgery (RAMIS); however, most pipelines are offline and depend on accurate camera trajectory priors (often from robotic kinematics), limiting applicability when priors are missing or noisy. To address these limitations, we propose Track2Map, an online 3D Gaussian Splatting pipeline that jointly optimizes camera trajectory and 3D deformable scene representation directly from surgical video.
LapaTrack-3D is a real‑time 6 DoF tracking algorithm designed for monocular laparoscopic surgery, aligning intra‑operative video with pre‑operative CT data. It modifies the ORB‑SLAM2 framework with four key changes: fast initialization using a primitive 3D shape, a pseudo‑segmentation strategy to isolate the target organ, incorporation of the 3D shape as a geometric prior in pose graph optimization, and enhanced imaging via a modified Multi‑Scale Retinex with Chromaticity Preservation algorithm. Experiments on in‑vivo and ex‑vivo data show robust tracking under challenging conditions such as poor illumination, fast motion, and partial visibility, achieving 13 Hz on 1280×720 video.
By Jingwei Song, Javid Hussain Jakir, Ray Zhang, Wenwei Zhang, Hao Zhou, Xiaomeng Xian, Maani Ghaffari
MV-dVRK is the first ex‑vivo surgical dataset that provides multiple exposure‑synchronized stereo viewpoints, accurate surface geometry, and ground‑truth camera poses for endoscopic images. The benchmark’s static subset offers dense SfM reference geometry validated against an industrial 3D scanner, while the dynamic sequences cover ten surgical tasks with increasing kinematic complexity and tissue deformation. Using MV‑dVRK, the authors systematically compare zero‑shot monocular, stereo, multi‑stereo, and multi‑view 3D reconstruction methods, finding that multi‑stereo reconstruction with two endoscopes yields the highest coverage, and that optimization‑based multi‑view methods outperform feed‑forward foundation models when a third viewpoint is added.
By Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa, Omer Burak Alada\u{g}, Yarden Sharon, Jens Rolinger, Ivan Capobianco, Anton Deguet, Siyu Tang, Katherine J. Kuchenbecker
arXiv:2610.07561v1 Announce Type: new
Abstract: Image-guided surgery (IGS) depends on accurate tracking of surgical instruments to provide real-time navigation relative to anatomical structures. Comm...
By George Sideris, Justin Cree, Andrew Stirling, Mamadou Ly, \'Etienne L\'eger, D. Louis Collins
EndoPrior-GS is a new pipeline for dynamic endoscopic reconstruction that combines frame-extracted vision heuristics with depth maps. It creates a joint texture prior using a tool-filtered tissue mask, a non-specular photometric filter, and anatomical salience, which guides primitive initialization and density control. Experiments on EndoNeRF and SCARED datasets show that EndoPrior-GS reduces Flow Error by 27.7% and 25.8% compared to representative methods while maintaining real-time rendering speed and competitive quality.
By Jiaqi Huang, Shidong Wang, Tong Xin, Kabita Adhikari
SCOPE-4D is an endoscopic 4D geometry foundation model that predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. The authors introduce SCOPE-5K, a curated dataset of about 5,000 real and synthetic gastrointestinal endoscopy and laparoscopy clips, and use it for geometric supervised fine‑tuning. Adding Common–Residual Motion (CRM) constraints and trajectory supervision further improves camera and depth estimation and enables dense 3D tissue tracking, as shown by evaluations on public and new benchmarks and a blinded user study.
By Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche, Run Wang, Terrence Chen, Siyu Huang, Ziyan Wu
arXiv:2609.27227v1 Announce Type: new
Abstract: Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic...
By Mehmet Kerem Turkcan, Soham Samal, Zoran Kostic
Wound3DAssist is a practical framework that creates 3D wound models from short handheld videos taken with consumer‑grade devices, enabling non‑contact, automatic measurements of wound surfaces. The system integrates 3D reconstruction, wound segmentation, tissue classification, and periwound analysis into a modular workflow. Evaluations on digital models, silicone phantoms, and real patients show millimeter‑scale reconstruction accuracy and multi‑view tissue composition analysis, with full assessments completed in under 20 minutes.
By Remi Chierchia, Rodrigo Santa Cruz, L\'eo Lebrat, Yulia Arzhaeva, Mohammad Ali Armin, Jeremy Oorloff, Chuong Nguyen, Olivier Salvado, Clinton Fookes, David Ahmedt-Aristizabal
The paper introduces PICO, an end-to-end trainable model for 6DoF surgical tool pose estimation that uses multi-task learning to predict segmentation, depth, and pose parameters. It incorporates two geometry-aware proxy tasks—a projection loss and a point-to-point loss—to enforce consistency in 2D and 3D spaces, improving accuracy and robustness. Evaluated on the SurgRIPE dataset, PICO achieves strong performance, ranking second in rotation accuracy and maintaining competitive translation results, especially under occlusion.
By Lucy Fothergill, Pietro Valdastri, Dominic Jones, Duygu Sarikaya
arXiv:2608.29928v1 Announce Type: new
Abstract: State-of-the-art monocular body recovery methods predict mesh vertices and angles on the corresponding kinematic tree, but their outputs lack biomechan...
By R. James Cotton, J. D. Peiffer, Lucinda Williamson, John Leske, Georgios Pavlakos
Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument...