The study fine‑tunes a pretrained 3D medical vision‑language model for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution. Two adaptation strategies—full fine‑tuning and parameter‑efficient fine‑tuning (PEFT)—both achieve strong performance (AUC 0.82/0.79, F1 0.71/0.70) despite cross‑institutional domain shift, with PEFT updating only ~1% of parameters. The work highlights the trade‑offs between rapid convergence and overfitting in full fine‑tuning versus the efficiency of PEFT, and shows that self‑supervised CT‑report contrastive learning can improve HCC classification without lesion‑level annotations.
By Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
arXiv:2510. 15042v3 Announce Type: replace-cross Abstract: In the 3D medical image domain, vision-language pre-training is used to create vision-language encoders (VLEs) that can support radiologists by retrieving patients with similar abnormalities, predicting likelihoods of abnormality, or, with downstream adaptation, generating radiological reports.
By Tassilo Wald, Ibrahim Ethem Hamamci, Yuan Gao, Sam Bond-Taylor, Harshita Sharma, Maximilian Ilse, Cynthia Lo, Olesya Melnichenko, Anton Schwaighofer, Noel C. F. Codella, Maria Teodora Wetscherek, Klaus H. Maier-Hein, Panagiotis Korfiatis, Valentina Salvatelli, Javier Alvarez-Valle, Fernando P\'erez-Garc\'ia
arXiv:2603.00479v2 Announce Type: replace
Abstract: Automated radiology report generation is key for reducing radiologist workload and improving diagnostic consistency, yet generating accurate report...
By Pengcheng Shi, Minghui Zhang, Kehan Song, Jiaqi Liu, Yun Gu, Xinglin Zhang
arXiv:2505. 18315v3 Announce Type: replace-cross Abstract: We introduce \textbf{CoLoRA} (Convolutional Low-Rank Adaptation), a parameter-efficient fine-tuning method for convolutional neural networks (CNNs).
By Mariano Rivera, Angello Hoyos
Meta-CLIP is a metadata‑conditioned contrastive learning framework that incorporates DICOM acquisition information to reweight cross‑modal negatives during medical vision‑language pretraining. By defining a bounded pairwise margin over numerical and categorical DICOM fields, the method emphasizes distinctions among studies with similar imaging conditions while keeping the kernel fixed during optimization. Evaluations on chest radiography and volumetric CT show that Meta‑CLIP improves zero‑shot classification performance, achieving higher macro‑AUROC scores than baseline CLIP models on multiple benchmarks.
By Haozhe Luo, Nirosh Sivanesan, Shelley Zixin Shu, Francesco Nitti, Mauricio Reyes
The paper introduces a reference-guided data curation method for training 3D medical vision‑language models. By using a small, high‑quality reference set to extract quality signals from large, uncurated image‑report pools and aggregating these signals into a single ranking, the authors can select a subset of data that yields competitive zero‑shot disease classification performance. Experiments on 35k 3D abdominal CT pairs and 58k 2D chest X‑ray pairs show that the curated models match or exceed baseline performance while using up to ten times less training data.
By Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel, Akshay S. Chaudhari