The study fine‑tunes a pretrained 3D medical vision‑language model for hepatocellular carcinoma (HCC) classification using paired abdominal CT scans and radiology reports from a different institution. Two adaptation strategies—full fine‑tuning and parameter‑efficient fine‑tuning (PEFT)—both achieve strong performance (AUC 0.82/0.79, F1 0.71/0.70) despite cross‑institutional domain shift, with PEFT updating only ~1% of parameters. The work highlights the trade‑offs between rapid convergence and overfitting in full fine‑tuning versus the efficiency of PEFT, and shows that self‑supervised CT‑report contrastive learning can improve HCC classification without lesion‑level annotations.
By Febryan Putra Kartika, Cheng-Yu Ma, Ying-Jia Lin, Chi-Tung Cheng, Kuan-Fu Chen
arXiv:2510. 15042v3 Announce Type: replace-cross Abstract: In the 3D medical image domain, vision-language pre-training is used to create vision-language encoders (VLEs) that can support radiologists by retrieving patients with similar abnormalities, predicting likelihoods of abnormality, or, with downstream adaptation, generating radiological reports.
By Tassilo Wald, Ibrahim Ethem Hamamci, Yuan Gao, Sam Bond-Taylor, Harshita Sharma, Maximilian Ilse, Cynthia Lo, Olesya Melnichenko, Anton Schwaighofer, Noel C. F. Codella, Maria Teodora Wetscherek, Klaus H. Maier-Hein, Panagiotis Korfiatis, Valentina Salvatelli, Javier Alvarez-Valle, Fernando P\'erez-Garc\'ia
arXiv:2603.00479v2 Announce Type: replace
Abstract: Automated radiology report generation is key for reducing radiologist workload and improving diagnostic consistency, yet generating accurate report...
By Pengcheng Shi, Minghui Zhang, Kehan Song, Jiaqi Liu, Yun Gu, Xinglin Zhang
arXiv:2505. 18315v3 Announce Type: replace-cross Abstract: We introduce \textbf{CoLoRA} (Convolutional Low-Rank Adaptation), a parameter-efficient fine-tuning method for convolutional neural networks (CNNs).
By Mariano Rivera, Angello Hoyos
Meta-CLIP is a metadata‑conditioned contrastive learning framework that incorporates DICOM acquisition information to reweight cross‑modal negatives during medical vision‑language pretraining. By defining a bounded pairwise margin over numerical and categorical DICOM fields, the method emphasizes distinctions among studies with similar imaging conditions while keeping the kernel fixed during optimization. Evaluations on chest radiography and volumetric CT show that Meta‑CLIP improves zero‑shot classification performance, achieving higher macro‑AUROC scores than baseline CLIP models on multiple benchmarks.
By Haozhe Luo, Nirosh Sivanesan, Shelley Zixin Shu, Francesco Nitti, Mauricio Reyes
The paper introduces a reference-guided data curation method for training 3D medical vision‑language models. By using a small, high‑quality reference set to extract quality signals from large, uncurated image‑report pools and aggregating these signals into a single ranking, the authors can select a subset of data that yields competitive zero‑shot disease classification performance. Experiments on 35k 3D abdominal CT pairs and 58k 2D chest X‑ray pairs show that the curated models match or exceed baseline performance while using up to ten times less training data.
By Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel, Akshay S. Chaudhari
MVC-Bench is a new benchmark designed to evaluate the calibration of vision‑language models (VLMs) and medical VLMs (Medical‑VLMs) for medical image classification. It tests calibration across robustness to modality, backbone, and domain shift; effectiveness of calibration strategies and prompt‑tuning methods; and stability under prompt‑template and random‑seed variations. The benchmark includes eight backbones, three medical modalities (fundus imaging, histopathology, chest X‑ray), and compares post‑hoc, train‑time, and zero‑shot calibration approaches, reporting accuracy, Expected Calibration Error (ECE), Maximum Calibration Error (MCE), and Adaptive Calibration Error (ACE) over 1,638 experiments, while also proposing a Multi‑Class Margin (MCM) regularization technique that improves ECE in most settings.
By Ashshak Sharifdeen, Shihab Aaqil Ahamed, Ufaq Khan, Muhammad Akhtar Munir Sujair Ibrahim, Mohamed Rafeek Mareer Ahamed, Yutong Xie, Imran Razzak, Muhammad Haris Khan
MVC-Bench is a calibration-focused benchmark for medical vision‑language models, evaluating how well these models express confidence across different modalities, backbones, and domain shifts. It tests robustness to modality, backbone, and domain changes, the effectiveness of calibration and prompt‑tuning strategies, and stability under prompt‑template and random‑seed variations. The benchmark includes 1638 experiments, reporting accuracy and Expected Calibration Error (ECE) along with other calibration metrics, and introduces a simple train‑time calibration method, Multi‑Class Margin (MCM) regularization, that achieves the lowest ECE in most settings.
The paper introduces two lightweight spectral adapters—Directional Spectral Adapter (DiSECT) and Spectral Instance-Guided Adapter (SiGA)—to adapt the Segment Anything Model (SAM) for accurate segmentation of colorectal liver metastases in contrast‑enhanced CT scans. SiGA achieves the highest single‑point Dice score of 0.77 and performs comparably to a 3D nnU‑Net baseline under no‑prompt inference, while DiSECT requires only 0.14 million trainable parameters. The study evaluates the adapters on 446 CT volumes across various prompting regimes, demonstrating that spectral adapters can efficiently adapt SAM with limited trainable parameters while maintaining strong segmentation accuracy.
By Ramtin Mojtahedi, Mohammad Hamghalam, Jacob J. Peoples, Natalie Gangai, Mithat Gonen, Yun Shin Chun, HyunSeon Christine Kang, Richard K. G. Do, Amber L. Simpson
arXiv:2610.34884v1 Announce Type: new
Abstract: Reusing pretrained medical-imaging models offers an alternative to training from scratch. A model trained for the same task may perform poorly at a new...
By Hanxue Gu, Zhonghao Liu, Xingrui Gu, Kang Wang, Yang Yang
nnFoundation introduces complementary convolutional and transformer-based 3D foundation models for radiology, trained on 2.1 million CT, MRI, and PET volumes from 125 datasets. The models are evaluated on 108 tasks—including segmentation, detection, classification, report generation, and image retrieval—under domain shift, low-data, and low-compute scenarios, consistently outperforming prior 3D foundation models and training from scratch. Performance varies by task type, with convolutional models excelling at spatially localized tasks and transformer models at global semantic reasoning, and dynamic alignment with dataset characteristics further enhances transferability.
By Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp, Maximilian Rokuss, Elisa Stegmeier, Philipp Schader, Dasha Trofimova, Raphael Stock, Kim-Celine Kahl, Stephen Schaumann, Selen Erkan, David Zimmerer, Stefan Denner, Moritz Langenberg, Sebastian Ziegler, Katharina Eckstein, Maximilian Fischer, Jonathan Suprijadi, B\'alint Kov\'acs, Benjamin Hamm, Anand Deshpande, Dimitrios Bounias, Nico Disch, Shuhan Xiao, Jessica K\"achele, Jan Sellner, Rajesh Baidya, Jeremias Traub, Lars Kr\"amer, Maximilian Zenk, Tim R\"adsch, Stefan Dvoretskii, Robin Peretzke, Jonathan Deissler, Alexandra Ertl, Partha Ghosh, Kris Dreher, Stefan Dinkelacker, Annika Reinke, Evangelia Christodoulou, Numan Saeed, Yoland Savriama, Santiago Estrada, David K\"ugler, Laura Alexandra Daza Barragan, Cristina Isabel Gonzalez Osorio, Jan Peeken, Michael Baumgartner, Marvin Teichmann, Guillaume Chabin, Matthias Kirchler, Valentin Koch, for the ALFA study, Markus Hohenhaus, Dimitri Koslov, Nina Decker, Mohammad Yaqub, Arnd Heuser, Martin Reuter, Julia A. Schnabel, Tobias Heimann, Florin Ghesu, Paul Brachmann, Claus P. Heu{\ss}el, Alexander Radbruch, Gianluca Brugnara, Aditya Rastogi, Martha Foltyn-Dumitru, Heinz-Peter Schlemmer, Ignaz Reicht, Julius C. Holzschuh, Michael Bach, Bram Stieltjes, Kai Schlamp, Lena Maier-Hein, Marco Nolden, Ralf Floca, Paul F. J\"ager, Philipp Vollmuth, Fabian Isensee, Klaus H. Maier-Hein
arXiv:2608.30844v1 Announce Type: cross
Abstract: Interactive lesion segmentation in whole-body PET/CT requires a model to provide a strong initial prediction while also responding efficiently to spa...
By Xinglong Liang, Chunyao Lu, Tianyu Zhang, Jiaju Huang, Tao Tan, Yunchao Yin, Lishan Cai