arXiv:2602. 11801v2 Announce Type: replace Abstract: Accurate localization of the seizure onset zone (SOZ) from intracranial EEG (iEEG) is essential for epilepsy surgery but is challenged by complex spatiotemporal seizure dynamics.
By Elham Rostami, Aref Einizade, Taous-Meriem Laleg-Kirati
arXiv:2607. 21384v1 Announce Type: new Abstract: Electroencephalography (EEG) models used for epilepsy are often limited to specific datasets and tasks.
By Targol Bakhtiarvand, Jugal Kalita, Adham Atyabi
arXiv:2506.20354v3 Announce Type: replace-cross
Abstract: Learning from multi-variate time-series with heterogeneous channel configurations remains a fundamental challenge for deep neural networks, p...
By Francesco Carzaniga, Michael Hersche, Abu Sebastian, Kaspar Schindler, Abbas Rahimi
arXiv:2608.21445v1 Announce Type: new
Abstract: Automated seizure detection from electroencephalography (EEG) is essential for continuous neurological monitoring, particularly for subclinical epilept...
By Chenxi Liu, Mingzhao Li, Yicong Liu, Hao Miao, Hongyuan Zhang, Ziyi Chen, Gaofeng Meng
arXiv:2609.22141v1 Announce Type: cross
Abstract: Automated seizure detection from scalp electroencephalography (EEG) is difficult because seizure morphology varies among patients and seizure samples...
By Maimuna Chowdhury, Sk. Imran Hossain
arXiv:2609.36087v1 Announce Type: cross
Abstract: Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristic...
By Yipeng Zhang, Chenda Duan, Yuanyi Ding, Tianyi Wang, Atsuro Daida, Masaki Izumi, Yuta Tanoue, Naoto Kuroda, Shaun A. Hussain, Nishant Sinha, Eishi Asano. Hiroki Nariai, Vwani Roychowdhury
arXiv:2607. 16296v1 Announce Type: cross Abstract: Continuous EEG monitoring for epilepsy is constrained by the limited power and memory budgets of wearable and implantable devices.
By Kartikey Ahlawat
arXiv:2607. 14314v1 Announce Type: new Abstract: Seizure diagnosis from EEG signals is a critical yet persistently challenging task, due to the complicated neural dynamics and the spurious connections in inter-channel modeling.
By Lincan Li, Zheng Chen, Yushun Dong
NeurDuo-EEG is a causal EEG foundation model that introduces channel‑resolved persistent memory and multi‑timescale memory management, allowing it to model continuous EEG with a fixed‑size state. Trained on 3,955 hours of EEG from 17 public datasets, it outperforms baselines on most short‑window and long‑sequence tasks, notably improving seizure detection AUC‑PR from 0.285 to 0.471. The Small variant achieves these gains with only 4.7 M parameters and supports efficient streaming inference with constant per‑chunk latency even as history grows to one hour.
By Yifan Wang, Haiping Liu, Yang Cui, Wenhao Cai, Shuhang Li, Xiaoyang Huang, Xianyang Liu, Jingyu Sun, Yizheng Sun, Cunhang Fan, Tianming Du, Jiancheng Yang, Zhenhong Li, Yunhao Zhang, Hongpeng Zhou, Jingyuan Sun
arXiv:2603. 19100v2 Announce Type: replace Abstract: Electroencephalography (EEG) enables non-invasive monitoring of brain activity across clinical and neurotechnology applications, yet building foundation models for EEG remains challenging due to differing electrode topologies and computational scalability, as Transformer architectures incur quadratic sequence complexity.
By Dana\'e Broustail, Anna Tegon, Thorir Mar Ingolfsson, Yawei Li, Luca Benini
arXiv:2607. 27105v1 Announce Type: cross Abstract: Most existing seizure detection algorithms require extensive pre-processing of the data and rely on heuristic or currently unexplainable machine learning approaches.
By Andrew Flynn, Cian McCafferty, Klaus Lehnertz, Fran\c{c}ois David, Vincenzo Crunelli, Gordon Lightbody, Sebastian Wieczorek
RobustSeiz is an open‑source, model‑agnostic framework designed to benchmark the robustness of EEG seizure detection models under realistic clinical stressors. It standardizes four public scalp‑EEG corpora into BIDS‑EEG trees, applies controlled distribution shifts—including environmental, noise, and adversarial transforms—across predefined hyperparameter grids, and reports comprehensive performance metrics such as sensitivity, precision, F1, false positives per 24 h, onset timing, and predictive agreement. The framework offers a Dockerized GPU pipeline, experiment registry, and both full‑evaluation and research‑subset modes, and demonstrates its utility by evaluating a contemporary detector on TUSZ across the full shift grid.
By Mohammad Mohammadi, Alireza Zarei