arXiv AI

Forensic Reproducibility Audit of a Radiology Vision-Language Model Benchmark: From Intended Protocol to Released Artifact

arXiv:2607. 25589v1 Announce Type: cross Abstract: Medical-imaging AI benchmarks combine datasets, DICOM rendering, prompts, provider APIs, automated labels, statistical code, manuscripts, and repository releases.

arXiv Machine Learning
Sep 21

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

The study evaluates the robustness of medical vision‑language models for tuberculosis screening on chest X‑rays by testing them across multiple datasets, prompts, and evaluation settings. Three specialized models (BioMedCLIP, CheXficient, MedSigLIP) and a general OpenCLIP model were audited on 12,200 images, producing 244,000 model–image–prompt scores. Results show that no model consistently outperforms others across all cohorts and reliability criteria, with prompt changes and control group composition significantly affecting AUROC, and that high training‑set performance does not reliably transfer to external cohorts.

By Mushir Akhtar, M. Tanveer, Mohd. Arshad
arXiv Machine Learning
Nov 11

RadRef: A Reference-Free Metric for Radiology Report Generation

RadRef is a new reference‑free metric for evaluating AI‑generated radiology reports by scoring report claims against image‑derived beliefs over a clinical finding vocabulary, weighted by relevance to the clinical indication. On the ReXVal benchmark it achieves 73.1% agreement with radiologist rankings for non‑tied same‑radiograph pairs, comparable to leading reference‑based metrics, and shows strong performance on false findings and omissions. In a reader study of 100 model‑generated and 100 radiologist‑authored reports, RadRef’s Kendall’s tau‑b for omissions (0.295) is close to the inter‑reader agreement (0.386), and its false‑finding readout (RadRef‑FF) also matches reference‑based metrics without needing a reference.

By Shelly Schwartz, Alan Ropp, Michael B. Sneider, Nur Yildirim, Cree M. Gaskin, Chirag Agarwal
arXiv AI
Sep 17

Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation

The study examines how differences in radiologists’ reporting styles—such as terminology, shorthand, formatting, and detail—affect the evaluation of AI-generated chest X‑ray reports. By quantifying the sensitivity of common metrics to these variations, the authors show that changes in reference reports can shift model rankings. They introduce a taxonomy of reporting variations and a rewriting method, ReRef, that preserves clinical meaning while altering style, and release a validated dataset of paired reference reports to aid future research.

By Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency, Pradeep Ravikumar, Zachary C. Lipton, Michael Oberst
arXiv AI
Jul 8

Harrison.Rad 1.5 Technical Report: A radiology foundation model that can draft reports from images, priors and clinical context

arXiv:2607. 05880v1 Announce Type: cross Abstract: Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone.

By Suneeta Mall, Vladimir Nekrasov, Ashnil Kumar, Sajith Karunasena, Aiden Nibali, Alix Bird, Mateo Diaz Shine, Jarrel Seah
arXiv Machine Learning
Aug 11

Auditing Medical Vision-Language Models on Chest Radiographs: Estimating Reference Agreement Across Institutions

arXiv:2608. 07550v1 Announce Type: cross Abstract: Vision-language models return structured chest-radiograph findings through interfaces exposing no confidence score, so a receiving institution cannot read off how far to trust an individual judgment.

By Pengyang Yu, Yiou Wang, Zhongping Dong, Sahraoui Dhelim, Chun-Mei Feng, M. Tahar Kechadi
arXiv AI
Sep 25

Med-AR: Autoregressive Vision-Language Pretraining for Long-Tailed Chest X-Ray Classification and Uncertainty-Aware Evaluation

Med-AR introduces two autoregressive vision‑language models, Med‑AR‑8B and Med‑AR‑2B, pretrained on structured radiology reports, abnormality‑focused text, and region annotations to address long‑tailed chest X‑ray classification. The models outperform existing contrastive, self‑supervised, and supervised encoders—including Med‑CLIP, CheXFound, EVA‑Base, ARK, and BioViL‑T—across PadChest, MIMIC‑CXR, and CheXpert, achieving higher mean AUROC and AUPRC for head, medium, and tail findings and lower excess area under the risk‑coverage curve. Med‑AR also demonstrates improved selective‑prediction performance, with Med‑AR‑8B raising tail‑label mean AUPRC on MIMIC‑CXR from 0.1033 to 0.1441 and Med‑AR‑2B delivering the strongest discrimination on PadChest.

By Janhavi Prabhu, Sahil, Akshay V, Shivam Shukla, Manoj Tadepalli, Preetham Putha
arXiv AI
Oct 27

Benchmarking Classification Tasks of Chest X-ray AI Across Multinational Public and Private Datasets: a retrospective diagnostic accuracy study

The study evaluated ten chest X‑ray AI classification models on 12 datasets from six countries, focusing on image‑level classification and measuring specificity at 95% sensitivity. MAVL and MedKLIP achieved the highest specificity (≈0.37) but still produced many false positives, with performance dropping on institutional cohorts compared to public benchmarks. No single model excelled across all findings, countries, or lesion types, highlighting limited generalisability.

By Qinmei Xu, Yiheng Li, Wenya Zhao, Zihao Zhao, Chuanjun Xu, Ahmet Gorkem Er, Xianghao Zhan, Brittany Dashevsky, Mohammed Alawad, Marc von der St\"uck, Marvin Gazibari\'c, Daniel Truhn, Shunsuke Shibata, Ryosuke Horino, Mio Ito, Akio Hiwatashi, Suyu Li, Mengya Yang, Ya Liu, Zhiyuan Sun, Changsheng Zhou, Haruka Itakura, Xiao Li, Olivier Gevaert
arXiv Computer Vision
5d ago

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

ProtoBridge-CLIP introduces a new framework that blends symmetric global image–report alignment with observation‑masked finding supervision and a soft relation objective over affirmed report concepts. The method aligns text‑derived finding prototypes with local visual tokens while excluding uncertain and unmentioned concepts from direct labels. Evaluations on multiple CT and chest‑radiograph benchmarks show consistent performance gains, achieving macro‑AUROC scores up to 91.4% on CheXpert and demonstrating robustness across retrieval, localization, and calibration tasks.

By Jinrui Wu, Yun Peng
arXiv Computer Vision
5d ago

Measuring and Attributing Evidence Sensitivity in Medical Vision-Language Models via Symmetric Counterfactual Controls

The paper introduces a Counterfactual Evidence Framework to evaluate medical vision‑language models (VLMs) by pairing lesion erasures with matched control edits, ring controls, and degraded views, thereby separating true visual discrimination from answer‑threshold shifts. Across 507 test cases, frontier VLMs correctly identify 41.1%–61.6% of erased lesions, while a counterfactual‑trained MedScope‑4B model achieves only 9.6%, with physician readers confirming the reliability of automated erasures in colonoscopy. The study also demonstrates that apparent utility gains stem from threshold adjustments rather than improved discrimination, and shows that retraining on pneumothorax cases can detect 53% of new pneumothoraxes without altering main‑test outcomes.

By Bhaskar Gurram