arXiv:2608. 00147v1 Announce Type: cross Abstract: Vision-language pretraining learns rich medical image representations from radiology reports, but previous model variants commonly operate within a single shared embedding space, so concept-level structure and interpretability must be recovered post hoc, limiting model transparency and, hence, clinical utility.
By Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf, Lena Schmitzer, Lea Schumann, Jannik Kahmann, Friedrich Puttkammer, Johannes Moll, Jannik L\"ubberstedt, Zeineb Ben Chaaben, Anirudh Narayanan, Cosmin I. Bercea, Sebastian Ziegelmayer, Marcus R. Makowski, Daniel Rueckert, Lisa C. Adams, Keno K. Bressem
arXiv:2409.16183v2 Announce Type: replace
Abstract: Radiology is a vital and complex component of modern clinical workflow and covers many tasks. Recently, vision-language (VL) foundation models in m...
By Xiaohong Liu, Guoxing Yang, Yulin Luo, Jiaji Mao, Xiang Zhang, Haibo Wang, Zhiyang He, Ming Gao, Shanghang Zhang, Jun Shen, Guangyu Wang
TransXplainRRG is a radiologist‑evaluated large vision‑language model that generates chest radiograph reports by combining a Swin Transformer vision encoder, a transformer‑based text encoder that incorporates patient medical history, and an LLM. The model uses an expert‑guided inside‑out approach to focus on abnormal findings and refine reports, aiming to balance high performance with explainability. Evaluated on MIMIC‑CXR and IU X‑Ray datasets, it achieves competitive standard metrics and higher GREEN scores (0.327 on MIMIC‑CXR, 0.605 on IU X‑Ray) than MAIRA‑2, with qualitative radiologist assessments supporting its clinical relevance.
By Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon
arXiv:2609.01470v1 Announce Type: new
Abstract: As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language...
By Charles Corbi\`ere, L\'eo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron, Corentin Dancette
arXiv:2601.15891v4 Announce Type: replace
Abstract: Vision-language pretraining has driven progress in medical image representation learning, but it depends on paired image-text data and can inherit...
By Anas Anwarul Haq Khan, Mariam Husain, Pratik Jalan, Kshitij Jadhav
The paper introduces Diagnostic Loss (DLoss), an objective designed to align radiology report generation with the asymmetric requirement of accurately stating supported diagnoses while avoiding unsupported ones. DLoss operates on decoder token probabilities, aggregating mass over vocabularies for supported and unsupported diagnoses and applying asymmetric pooling to encourage correct diagnoses and suppress spurious ones. Applied to various 3D MedVLMs on 50,000 abdominal CT scans, DLoss improves diagnostic faithfulness without compromising conventional language‑generation metrics.
By Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jaros{\l}aw B. \'Cwik{\l}a, Arkadiusz Sitek, Pedro R. A. S. Bassi, Szymon P{\l}otka