The study examines how differences in radiologists’ reporting styles—such as terminology, shorthand, formatting, and detail—affect the evaluation of AI-generated chest X‑ray reports. By quantifying the sensitivity of common metrics to these variations, the authors show that changes in reference reports can shift model rankings. They introduce a taxonomy of reporting variations and a rewriting method, ReRef, that preserves clinical meaning while altering style, and release a validated dataset of paired reference reports to aid future research.
By Daniel P. Jeong, Charles Q. Li, Hossein Hosseiny, Nitya M. Bhalla, Fatma Uyar Morency, Pradeep Ravikumar, Zachary C. Lipton, Michael Oberst
arXiv:2609.01470v1 Announce Type: new
Abstract: As AI systems are increasingly used to draft radiology reports, reliably evaluating their clinical quality remains a critical challenge. Large language...
By Charles Corbi\`ere, L\'eo Machado, Aubin Charley, Baptiste Callard, Pierre Manceron, Corentin Dancette
arXiv:2609.27607v1 Announce Type: cross
Abstract: An AI-generated radiology report can resemble a physician's report while omitting an abnormality, adding an unsupported finding, or reversing its pre...
By Jiaju Huang, Hao Yang, Xinyu Ma, Xinglong Liang, Kunyan Cai, Junqiang Ma, Shaobin Chen, Yue Sun, Tao Tan
The paper evaluates large language model (LLM) judges for radiology report assessment across multiple imaging modalities and anatomical regions, comparing four existing metrics (RadFact, GREEN, FineRadScore, CRIMSON) with a new metric called VERT. GREEN emerges as the most robust among current metrics, while VERT improves correlation with radiologist judgments by up to 26% over GREEN. The study also shows that ensembling and lightweight fine‑tuning of the Qwen3‑30B model can yield additional performance gains and significant latency reductions.
By Federica Bologna, Jean-Philippe Corbeil, Matthew Wilkens, Asma Ben Abacha
arXiv:2607. 05880v1 Announce Type: cross Abstract: Imaging demand is growing faster than the radiology workforce can expand, and reporting backlogs cannot be resolved through training and recruitment alone.
By Suneeta Mall, Vladimir Nekrasov, Ashnil Kumar, Sajith Karunasena, Aiden Nibali, Alix Bird, Mateo Diaz Shine, Jarrel Seah
arXiv:2607. 26333v1 Announce Type: cross Abstract: Chest X-ray (CXR) machine learning relies heavily on automated evaluation using reference standards that aim to approximate clinical judgment.
By Panagiotis Fytas, Ian Selby, Clemens Karner, Judith Babar, Simon Baker, Jake Beckford, Timothy J. Sadler, Shahab Shahipasand, Arthikkaa Thavakumar, John Li Chen, Alex Sawer, Michael Roberts, Jonathan Weir-McCall, J. H. F. Rudd, Carola-Bibiane Sch\"onlieb, Anna Korhonen, Anna Breger
arXiv:2606. 17062v1 Announce Type: cross Abstract: Radiology report evaluation must distinguish clinical compatibility from surface similarity, because negation, laterality, or normal-abnormal polarity can reverse a finding.
By Zhenhong Yang, Zhuoyun Liu, Jintao Fei, Wen Tang, Shichao Quan, Jun Zhao, Jun Xu
TransXplainRRG is a radiologist‑evaluated large vision‑language model that generates chest radiograph reports by combining a Swin Transformer vision encoder, a transformer‑based text encoder that incorporates patient medical history, and an LLM. The model uses an expert‑guided inside‑out approach to focus on abnormal findings and refine reports, aiming to balance high performance with explainability. Evaluated on MIMIC‑CXR and IU X‑Ray datasets, it achieves competitive standard metrics and higher GREEN scores (0.327 on MIMIC‑CXR, 0.605 on IU X‑Ray) than MAIRA‑2, with qualitative radiologist assessments supporting its clinical relevance.
By Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong, Shreya Ghosh, Tom Gedeon
arXiv:2608. 00147v1 Announce Type: cross Abstract: Vision-language pretraining learns rich medical image representations from radiology reports, but previous model variants commonly operate within a single shared embedding space, so concept-level structure and interpretability must be recovered post hoc, limiting model transparency and, hence, clinical utility.
By Fabian Drexel, Marlene Fritzsche, Era Stambollxhiu, Miriam Kumpf, Lena Schmitzer, Lea Schumann, Jannik Kahmann, Friedrich Puttkammer, Johannes Moll, Jannik L\"ubberstedt, Zeineb Ben Chaaben, Anirudh Narayanan, Cosmin I. Bercea, Sebastian Ziegelmayer, Marcus R. Makowski, Daniel Rueckert, Lisa C. Adams, Keno K. Bressem
arXiv:2607. 25589v1 Announce Type: cross Abstract: Medical-imaging AI benchmarks combine datasets, DICOM rendering, prompts, provider APIs, automated labels, statistical code, manuscripts, and repository releases.
By Mateusz Koz{\l}owski
arXiv:2608. 10505v1 Announce Type: new Abstract: Automated radiology report generation is advancing rapidly in response to the shortage of radiologists, yet unlike a perception model, existing generation models offer no control over the sensitivity-specificity trade-off of their diagnostic content.
By Ying Jin, Noel C. F. Codella, John Corring, Mu Wei, Dinei Florencio, Eric Horvitz
arXiv:2604.09537v2 Announce Type: replace
Abstract: A grounding verifier checks a statement about a patient's image against the radiology report and the cited evidence. The state-of-the-art methods f...
By Soroosh Tayebi Arasteh, Mehdi Joodaki, Mahshad Lotfinia, Tri-Thien Nguyen, Sebastian Ziegelmayer, Sven Nebelung, Daniel Truhn