arXiv AI

JSolver: Joint Spectrum Estimation and Multi-Material Decomposition from Single-Energy CT Projections

Hugging Face Trending Papers
Jun 29

A Dual-domain Refinement Network with FBP-based Jacobian Learning for Sparse-view Dual-Energy CT Material Decomposition

Dual-energy CT (DECT) exploits attenuation differences across different X-ray spectra to provide richer material information and has been widely used in medical imaging. While sparse-view acquisition can lower radiation exposure, it makes DECT material decomposition even more challenging, as the problem is nonlinear and ill-posed.

arXiv Computer Vision
Sep 4

$K$-NeAS: Scalable Multi-Material CT Reconstruction Using Neural SDFs

The paper introduces $K$-NeAS, a scalable neural architecture for multi-material CT reconstruction that replaces separate material networks with a shared latent backbone and a differentiable $K$-material soft selector. It automates attenuation bounds using a Gaussian Mixture Model and adds a scheduled auxiliary floater loss to reduce geometric hallucinations in sparse-view settings. Evaluated on four clinical CBCT datasets, $K$-NeAS achieves higher 3D volumetric fidelity—up to a 1.88 dB PSNR gain over a single-material baseline—and shows improved robustness under extreme sparsity, outperforming baselines by up to 1.17 dB.

By Daksh K. Shah, Emmanouil Nikolakakis, Razvan Marinescu
arXiv AI
Jul 31

PatchDenoiser: Parameter-efficient multi-scale patch learning and fusion denoiser for Low-dose CT imaging

arXiv:2602. 21987v3 Announce Type: replace-cross Abstract: Low-dose CT images are essential for reducing radiation exposure in cancer screening, pediatric imaging, and longitudinal monitoring protocols, but their quality is often degraded by noise from low-dose acquisition, patient motion, or scanner limitations, affecting both clinical interpretation and downstream analysis.

By Jitindra Fartiyal, Pedro Freire, Sergei K. Turitsyn, Sergei G. Solovski
arXiv AI
Jun 10

Deep Slice Interpolation for Reducing Through-Plane Anisotropy and Noise in Head CT

arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.

By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
arXiv Machine Learning
2d ago

A deep dictionary network-based foundation model for ultra-low-dose CT denoising

The paper introduces a deep dictionary network (DDN) foundation model designed for ultra‑low‑dose CT (ULDCT) denoising across multiple organs. By cascading convolutional sparse coding layers with iterative soft‑thresholding, the architecture offers inherent interpretability, while dynamic dictionary and threshold modules enhance representation. The model is pre‑trained on over one million normal‑dose CT images and fine‑tuned on multi‑organ ULDCT datasets, achieving state‑of‑the‑art performance that consistently outperforms existing methods.

By Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu, Huazhu Fu
arXiv AI
Aug 18

CG-GLORE: A Conjugate Gradient-Based Global-Local Regularization Network for Sparse-View CT Reconstruction

arXiv:2608. 15246v1 Announce Type: cross Abstract: Sparse-view computed tomography (CT) reduces radiation dose by acquiring fewer projection views, but the resulting inverse problem is highly ill-posed and often produces severe streak artifacts.

By Tran Xuan Hieu Le, Doanh C. Bui, Vu Trung Duong Le, Hoai Luan Pham, Khang Nguyen, Mai K. Nguyen, Tu Bao Ho, Yasuhiko Nakashima
arXiv Computer Vision
2d ago

Efficient 3D Whole-Body PET Image Denoising via Conditional Rectified Flow With Optimized Sampling Strategy

The paper introduces a one‑pass conditional 3D rectified flow (3D Flow) framework for denoising whole‑body PET images, employing an optimized non‑uniform sampling strategy and a linear‑interpolant velocity‑matching objective. It reconstructs a full 3D volume in about 30 seconds, dramatically faster than multi‑hour 3D diffusion models, while maintaining high global image quality and lesion conspicuity even at ultra‑low doses (down to 1/100 of standard). Zero‑shot transfer tests on independent clinical data demonstrate robust performance across datasets and unseen dose levels.

By Jiale Shen, Guolin Wang, Chenhao Wang, Xinhui Su, Wei Luo, Feng Yu
arXiv Computer Vision
Aug 31

Physics-Guided Flow Matching for CT Image Reconstruction

The paper introduces a high‑resolution Rectified Flow Matching model trained on 256×256 chest CT images to serve as a generative prior for CT reconstruction. A two‑stage training strategy—initial strong anatomically informed augmentation followed by fine‑tuning—helps mitigate overfitting and improve structural fidelity. When evaluated on various CT inverse problems, Flow Matching‑based reconstruction methods outperform diffusion‑based algorithms in PSNR, SSIM, and perceptual quality while requiring fewer sampling steps.

By Davide Evangelista
arXiv AI
Jul 29

Matrix-Free Photoacoustic Image Reconstruction via Sensor-Token Self-Attention

arXiv:2607. 25576v1 Announce Type: new Abstract: Photoacoustic tomography (PAT) combines the optical absorption contrast of biological tissue with the spatial resolution of ultrasound, yet recovering the initial pressure distribution from sparse-view sensor measurements remains an ill-posed inverse problem.

By Mary John, Shibili Said, Imad Barhumi, Sherzod Turaev, Mohamed Yahia
arXiv AI
Jul 15

From Reconstruction to Interpretation: Zero-Setup Multi-Phase Segmentation of X-ray Tomography Data

arXiv:2607. 12175v1 Announce Type: cross Abstract: X-ray tomography enables nondestructive characterization of material microstructures, while advances in micro-CT imaging have accelerated volumetric data acquisition and reconstruction.

By Pradyumna Elavarthi, Arun J. Bhattacharjee, Harrison Lisabeth, Anca Ralescu, Petrus H. Zwart, Dilworth Parkinson, Elizabeth G. Clark