arXiv:2606. 15457v1 Announce Type: cross Abstract: 3D FLAIR MRI is widely recommended as one of the standard MRI sequences for brain imaging in multiple sclerosis (MS), but publicly available MS datasets remain relatively small and vary across scanners, acquisition protocols, and lesion patterns.
By Weidong Zhang, Yongchan Jung, Shafayat Mowla Anik, Furen Xiao, Vasudevan Janarthanan, Enkhzaya Chuluunbaatar, Byeong Kil Lee, Jeeho Ryoo
arXiv:2602. 23214v2 Announce Type: replace-cross Abstract: Plug-and-Play diffusion prior (PnPDP) frameworks have emerged as a powerful paradigm for solving imaging inverse problems by treating pretrained generative models as modular priors.
By Chenhe Du, Xuanyu Tian, Qing Wu, Muyu Liu, Jingyi Yu, Hongjiang Wei, Yuyao Zhang
arXiv:2606. 19651v1 Announce Type: new Abstract: Three-dimensional (3D) brain MRI is central to clinical neurology and neuro-oncology, where generative models could augment under-represented cohorts, simulate disease trajectories, and support privacy-preserving data sharing.
By Max Van Puyvelde, Ibrahim Gulluk, Wim Van Criekinge, Olivier Gevaert
arXiv:2602. 18400v3 Announce Type: replace-cross Abstract: Missing data problems, such as missing modalities in multi-modal brain MRI and missing slices in cardiac MRI, pose significant challenges in clinical practice.
By Junkai Liu, Nay Aung, Theodoros N. Arvanitis, Joao A. C. Lima, Steffen E. Petersen, Le Zhang
Brain tissue microstructure estimation with machine learning provides higher computational efficiency than conventional fitting. However, machine learning still presents important limitations that hamper its clinical utility.
arXiv:2607. 20136v1 Announce Type: cross Abstract: Slice-to-volume reconstruction (SVR) is the standard method for obtaining high-resolution (HR) 3D fetal brain volumes from motion-corrupted 2D MRI slice stacks acquired in multiple orientations.
By Busra Bulut, Maik Dannecker, Thomas Sanchez, Sara Neves Silva, Steven Jia, Jean-Baptiste Ledoux, Leo Pomar, Joanna Sichitiu, Yvan Gomez, Meriam Koob, Vincent Dunet, Maria Deprez, Guillaume Auzias, Francois Rousseau, Jana Hutter, Daniel Rueckert, Meritxell Bach Cuadra
arXiv:2603. 05693v2 Announce Type: replace-cross Abstract: Accurate longitudinal analysis of brain MRI is often hindered by evolving lesions, which bias automated neuroimaging pipelines.
By Zahra Karimaghaloo, Dumitru Fetco, Haz-Edine Assemlal, Hassan Rivaz, Douglas L. Arnold
arXiv:2606. 26764v1 Announce Type: cross Abstract: Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions.
By Yiheng Cao, Gustavo Andrade-Miranda, Jiatian Zhang, Lingxiao Zhao, Xin Gao
arXiv:2606. 09953v1 Announce Type: cross Abstract: Head computed tomography (CT) typically uses sub-millimeter in-plane resolution but 2-5 mm through-plane spacing, creating substantial anisotropy that degrades multiplanar reconstructions, volumetric measurements such as hematoma volume estimation, and downstream algorithms that assume near-isotropic voxels.
By Luis Cort\'es Ferre, Miguel A. Guti\'errez-Naranjo, Marcin Balcerzyk
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation.
The paper introduces CM-RED, a fast MRI reconstruction method that combines a pretrained consistency model with the regularization by denoising framework. By integrating controlled noise injection into accelerated proximal gradient updates, CM-RED achieves high‑quality reconstructions on fastMRI knee and brain datasets with only four network function evaluations. It consistently outperforms existing diffusion‑ and consistency‑based approaches in quantitative metrics, visual fidelity, and robustness to hyperparameter changes.
By Merve G\"ulle, Junno Yun, Ya\c{s}ar Utku Al\c{c}alar, Mehmet Ak\c{c}akaya
arXiv:2608.29820v1 Announce Type: new
Abstract: Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservatio...
By Juneyong Lee, Jaeyoung Choi